Laserfiche WebLink
secondary • <br /> Vacuum Sensing System <br /> Maximize protection with a vacuum <br /> monitored secondary containment . <br /> system . <br /> A Secondary Containment Vacuum Features and Benefits Facilitates periodic operability testing <br /> Sensing System for use with Veeder- Satisfy Requirements Leverage Existing Veeder=Root Systems <br /> Root's ATG Systems . The Secondary Certified to meet California's requirement for . Uses Srp as the vacuum source and works with <br /> Containment Vacuum Sensing (SCVS) secondary space monitoring for tanks and lines RedJacket and FE STPs <br /> as required by AB 2481 • Installs in the STP sump and connects to the <br /> System is designed to detect leaks in double- Satisfies the requirements for Class I Leak console via intrinsically safe wiring <br /> walled tanks and piping systems while Detection as defined by the European . Able to share wiring conduit with other <br /> Standard EN 13160-2intrinsically robes and <br /> helping to contain a release of product while 3rd P National Work Groupand LGI13 ��ROOt umsafe (15) p <br /> under vacuum. The system consists of: listed sensors including sump en line leak sensors <br /> • Interfaces to the Smart Sensor Interface with <br /> • <br /> Embedded Pressure Module <br /> Vacuum Sensors , connected to tank, Reduce Exposure to Risk <br /> Alarms when vacuum cannot be maintained Provides for positive shut down of pressurized <br /> sump or piping interstices or when replenish rate exceeds 85 liters per hour lines when required <br /> • A Submersible Turbine Pump (STP) , Simple installation, no need to mess with brine <br /> • The system alarms when liquid is detected in <br /> to provide a source of vacuum the secondary space <br /> • A Smart Sensor Interface with Embedded <br /> Pressure Module in a TLS-350 Operating Temperature Rating: Console Capability <br /> Monitoring System -25 degrees C to +70 degrees C The Vacuum Sensor is compatible with <br /> g Y the following consoles: <br /> Cable Length : Console <br /> The Vacuum Sensor is interfaced to Veeder- 8 feet TLS-350R/EMC w/BIR* <br /> Root's TLS-350 Monitoring System via TLS-350 Plus/EMC Enhanced* <br /> intrinsically safe wiring to provide system Sensor Dimensions : TLS-350/EMC* <br /> *Upgrade Note: The Vacuum Sensor System requires <br /> status, replenish rate, alarm, and diagnostic 5" high x 5" wide 2" deep the console to have version 24C software (or greater) <br /> information. along with an ECPU2 or ECPU w/ NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a variety Veeder- Root P/N Description <br /> 330020-467 4 Vacuum Sensor Kit' for steel tank <br /> of models: 330020-4689-4691-470471 4 Vacuum Sensor Kit' for fiberglass tanks (4',6',8',10) <br /> 330020-486 4 Vacuum Sensor Kit' for no tank <br /> • For monitoring double-walled piping 330020-472 3 Vacuum Sensor Kit* for steel tank <br /> 330020-4731-474s-4751-476 3 Vacuum Sensor Kit* for fiberglass tanks (4',6',8' ,1 o') <br /> and sump interstices 330020-485 3 Vacuum Sensor Kit' for no tank <br /> • For monitoring double-walled steel tank 330020-479 2 Vacuum Sensor Kit* for steel tank <br /> interstices (see back page) 330020-481s-4821-483$-484 2 Vacuum Sensor Kit' for fiberglass tanks (4',6',8',10') <br /> P g 330020-480 2 Vacuum Sensor Kit* for no tank <br /> • For double-walled fiberglass tanks 330020-495 1 Vacuum Sensor Kit* for no tank <br /> 857280-100 Vacuum Sensor for piping R sumps <br /> 857280-200 Vacuum Sensor for steel tanks <br /> These kits differ in the number of vacuum <br /> 857280-301 - 302 -303 -304 Vacuum Sensor for fiberglass tanks (4',6',8',10') <br /> sensors and the configuration of associated 330020-448 Mounting Kit <br /> liquid sensors. An inline kit mounted liquid 332217-001 Relief Valve Assembly <br /> 332250-001 Smart Sensor w/Embedded Pressure Sensor Module (7 Channe)** <br /> sensor is used for Vacuum Sensors <br /> monitoring piping and sumps. An external Accessories Part Description Quantity/Length Part Number <br /> 1/4" NPT Barbed Fittings 3 330020-487 <br /> liquid sensor (to be installed in the secondary 1 /4" NPT Barbed Fittings 15 330020-488 <br /> space at the bottom of the tank) is provided 1 /4" NPT Barbed Fittings 25 330020-489 <br /> Barbed Tee 1 576008-657 <br /> with one of the Vacuum Sensors in the steel <br /> Vacuum Hose 25' 25' 332310-001 <br /> and fiberglass tank kits to monitor the tank. Vacuum Hose 50' 50' 332310-002 <br /> Vacuum Hose 100' 100' 332310-003 <br /> 3-Way Ball Valve 1 576008-649 <br /> Schrader Valve Barbed Fitting 3 330020-496 <br /> Schrader Valve Barbed Fitting 15 330020-497 <br /> IUs include mounting bracket, 6' of vacuum hose, relief valve assembly (d required) and the appropriate number of liquid sensors, <br /> 3-way ball vaFres, barbed fittings and hose damps so that each vacuum sensor can monitor a single lank, sump or gping interstim. <br /> " The Vacuum Sensing System requires one 7 channel Smart Sensor Interface veth Embedded Pressure Module, 8 channel Smart <br /> Sensor Modules (p/n 329356-004) can be used for Vacuum Sensors tight and above. <br /> For more information call : 1 - 888 -561 - 7942 <br /> VEEDER- ROOT <br />