Laserfiche WebLink
SUPPORTS MANIFOLDED LINES <br /> One transducer per manifolded line is required <br /> THE REDJACKETSTP THE REDJACKETSTP <br /> STPs . Piping <br /> Supports a wide-range of pump and pipe types. Utilizes Swiftcheck Valve on early generation Red Jacket Standard STPs. <br /> For further details, click here for the Line Leak Application Guide <br /> Line Leak Transducer Specifications <br /> Operating Temperature -25 OF to +130 OF <br /> Unleaded Gasoline • Biodiesel (Up to 6100) <br /> Leaded Gasoline • Kerosene <br /> Compatible Fuel Types 5% Methanol • Jet Fuel <br /> Up to 100% Ethanol • Aviation Gasoline <br /> 15% MTBE • DEF <br /> Diesel <br /> Line Flow Rate 120 GPM Max w/ Swiftcheck Valve <br /> Operating Range 0 — 70 PSI <br /> Proof Pressure 200 PSI <br /> Maximum Vertical Pipeline Height Above Transducer 11 ft <br /> Minimum Pump Output Pressure 23 PSI <br /> Maximum Volume of Fuel Monitored TLS-450PLUS — 1178 gallons <br /> TLS-350 — 212 gallons <br /> TLSm45OPLUS Line Leak Digital Transducer Ordering <br /> Part Number4 D - <br /> 859080.001 Digital Pressurized Line Leak Detector (DPLLD) without SwiftCheck Valve, UL <br /> 859080- 002 Digital Pressurized Line Leak Detector (DPLLD) with SwiftCheck Valve, UL <br /> 332812- 001 16 Input Universal Sensor Module (USM) <br /> 332813-001 5 Universal Input/Output Interface Module (UIOM), Relay Control and Input Signal Monitoring <br /> 332972- 007 Ultimate Testing: Digital Line Leak Detection* <br /> 332972-008 Risk Management: Digital Line Leak Detection* <br /> 332972-009 Base Compliance: Digital Line Leak Detection* <br /> 1 Line Leak Analog Transducer Ordering <br /> i <br /> 848480-001 Pressurized Line Leak Detector (PLLD) without SwiftCheck Valve, UL <br /> 848480-003 Pressurized Line Leak Detector (PLLD) with SwiftCheck Valve, UL <br /> 330843-001 6 Input Pressurized Line Leak Interface for use with PLLD Module <br /> 330374- 001 3 Output Pressurized Line Leak Controller <br /> 330160- 010 Ultimate Testing: Pressurized Line Leak Detection (PLLD)* <br /> 330160- 060 Risk Management: Pressurized Line Leak Detection (PLLD)* <br /> 330160-050 Base Compliance: Pressurized Line Leak Detection (PLLD)* <br /> * One per system required for precision line leak detection capability. <br /> NOTF: The TLS-350 analog transducer is not compatible with the TLS-450PLUS ATG . <br /> 125 Powder • - Drive a • • Box 200306070 a @2020 - • • - • • . 614 <br /> All information contained in this document is subject to change without notice. VEEDER— ROOT <br /> 3942 ' • ' • <br />