My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4747
>
2300 - Underground Storage Tank Program
>
PR0232482
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/17/2024 4:26:39 PM
Creation date
4/19/2022 11:21:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0232482
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003719
FACILITY_NAME
WEST LANE CHEVRON
STREET_NUMBER
4747
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4747 WEST LN STOCKTON 95210
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
180
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UL/ ULC Listed Red Thread ® IIA Piping System <br /> RED THREAD IIA PIPING RED THREAD IIA <br /> RED THREAD IIA Primary Piping Secondary Containment Piping <br /> Nom . Pipe Size Part Number Pipe Length Nom . Pipe Size Part Number Pipe Length <br /> ( In . ) mm (ft . ) ( in . ) mm (ft ) <br /> 2 50 011020-069- 1 15 3 80 011030-0694 15 <br /> 2 50 011020-069-2 22-25 3 80 011030-069-5 22-25 <br /> 2 50 011020-069 -3 26 -30 3 80 011030- 069-6 26 -30 <br /> 3 80 011030 -069 - 1 15 4 100 011040-077-5 15 <br /> 3 80 011030-069-2 22 -25 4 100 011040-069-5 22-25 <br /> 3 80 011030-069-3 26 -30 4 100 011040-077-6 26 -30 <br /> 4 100 011040-071 - 1 15 6 150 011060- 120-5 15 <br /> 4 100 011040 -069 -2 22-25 6 150 011060- 1204 22-25 <br /> 4 1 100 011040 -071 - 3 26 -30 r�61 150 011060- 120 -6 26-30 <br /> DIMENSIONAL DATA <br /> Nominal Nominal External Pressure <br /> PiNominal Nominal Wall Nominal Pressure/ Mill Test Max . Rating <br /> Pipe I . D . O . D . Weight Temperature Pressure (psig/ MPa) <br /> Size ( In . ! ( In ./mm ) ( Ind . ) Thickness ( Ibs .lft . / _ : ) Max . Rating ( psig/MPa) <br /> t1-11111 )11-11111 ) ( In ./ mm ) 750F1240 C 150° F1660C <br /> 2 2 .235 2 . 375 .070 0 .5 250 psig @ 150° F 375 85 80 <br /> 50 57 61 1 . 78 0 . 74 1 . 72 MPa @ 66 ° C 2 . 59 . 57 . 55 <br /> 3 3 . 360 3 . 500 .070 0 .7 175 psig @ 150 ° F 300 36 34 <br /> 80 85 90 2 . 54 1 . 04 1 . 21 MPa @ 66 ° C 2 . 07 . 25 . 23 <br /> 4 4 . 360 4 .560 .085 1 .2 125 psig @ 150° F 265 34 30 <br /> 100 111 116 2 . 16 1 . 79 0 . 86 MPa @ 660C 1 . 83 . 23 . 21 <br /> 6 6 .408 6 .678 . 135 2 .4 20 psig @ 150° F 265 22 20 <br /> 150 163 170 3 .43 3 . 51 0714 @ 66 ° C 1 . 83 . 15 <br /> RED THREAD IIA Pipe Bending Radius , Minimum <br /> PROPERTYpsi @ 75° F MPa @ 24° C psi @ 150 ° F MPa @ 66°C Nominal <br /> Axial Tensile (ASTM D2105) Pipe Size 2 " 3 " 4" 6 " <br /> Ultimate Stress 107300 71 . 0 81200 56 .5 (inches) <br /> Design Stress 2 , 575 17 . 8 21050 14 . 1 Ft , 75 110 140 204 <br /> Modulus of Elasticity 1 .82 x 106 12548 1 .42 x 106 9791 1 m 21 .3 133 . 5 , 42 .7 L62 . 2 <br /> Axial Compression (ASTM D695 ) ( 1 ) All values except pressure-temperature <br /> Ultimate Stress 33 , 300 230 . 0 25 , 600 177 . 0 maximum rating are nominal values_ Tolerances <br /> Design Stress 8 ,300 57 . 2 67400 44 , 1 or maximum/minimum limits can be obtained <br /> Modulus of Elasticity 1 .26 x 106 8687 . 89 x 106 6136 from Smith FibercasL <br /> (2) All sizes can accept full vacuum pressures <br /> Beam Bending (SFPTM ) at maximum temperature ratings. <br /> Ultimate Stress 23 , 000 159 . 0 19 , 200 132 .0 (3) Ultimate and allowable design stresses are <br /> based on minimum reinforced wall thickness. <br /> Design Stress(4) 27900 20 . 0 2 ,400 16 . 5 Pipe is manufactured in compliance with ASTM <br /> Modulus of Elasticity 2 . 18 x 106 15031 1 .70 x 106 11721 132996. <br /> ( Long Term 2er ASTM D2925 ) (4) Design bending stress is 118 of ultimate to <br /> Hydrostatic Burst ASTM 131599 account for combined stress (Le . bending and <br /> y ( ) pressure). <br /> Ultimate Hoop (5) Design stress is based on long term cyclic <br /> Tensile Stress 34 , 000 234 39 , 200 271 fatigue data using ASTM D2992 test method . <br /> Hydrostatic Design (ASTM D2992 ) 2"-3" 2" & 3 " 2" & 3" 2" & 3" However, all testing is not complete at time of <br /> printing. <br /> Procedure A 9 ,410(5) 64 . 9 (5) 79400(7) 51 (8) (6) For RED THREAD IIA pipe the hydrostatic <br /> Cyclic 150 X 106 4"-6" 4 "-6" 4"-6" 4 "-6" cyclic design stress was determined at 1500 and <br /> Cycles 13 ,040 (6) 89 . 9(6) 10 ,450 72 . 1 200° F, per ASTM D2992 Procedure A. Based <br /> y on this data , the extrapolated value at 75° F is <br /> Coefficient of Linear 0 .88 x 10-5 in ./in ./° F 13,030 psi . <br /> Thermal Expansion (SFPTM ) 1 . 58 x 10-5mm/mm/0C (7) For RED THREAD IIA pipe the hydrostatic <br /> Specific Gravity 1 $ cyclic design stress was determined at 750 and <br /> p y 200° F, per ASTM D2992 Procedure A. Based <br /> Flow Factor on this data , the extrapolated value at 150° F is <br /> Hazen -Williams Coefficient 150 7,400 psi . <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.