Laserfiche WebLink
October 11, 2021 Lab ID : STK2154072 <br />Live Oak Geo Environmental Customer : 3-16608 <br />Quality Control - Inorganic <br />Constituent <br />Office & Laboratory <br />Method <br />Date/ID <br />I Y lx <br />Units <br />Conc. <br />QC Data <br />DQO <br />Note <br />Wet Chem <br />Nitrate + Nitrite as N <br />450ONO3F <br />10/01/21:211438vvh <br />Blank <br />mg/L <br />ND <br /><0.2 <br />LCS <br />mg/L <br />11.22 <br />101% <br />80-120 <br />MS <br />mg/L <br />5.609 <br />100% <br />5-285 <br />(V12147746-001) <br />MSD <br />mg/L <br />5.609 <br />1.03% <br />5-285 <br />MSRPD <br />m /L <br />5.609 <br />2.9% <br /><30.4 <br />450ONO3F <br />10/01/21:215375vvh <br />CCB <br />mg/l <br />0.0640 <br />0.2 <br />CCV <br />mg/l <br />11.22 <br />98.6% <br />90-110 <br />CCB <br />mg/l <br />0.0300 <br />0.2 <br />CCV <br />I mg/l <br />11.22 <br />99.10/t <br />1 90-110 <br />urate Nitrogen <br />450ONO3F <br />10/01/21:211438vvh <br />Blank <br />m /L <br />ND <br /><0.2 <br />Definition <br />CCV <br />: Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />CCB <br />: Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />Blank <br />: Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br />LCS <br />: Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte recovery. <br />MS <br />: Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication of how that sample <br />matrix affects analyte recovery. <br />MSD <br />: Matrix Spike Duplicate of MS/MSD pair - A random sample duplicate is spiked with a known amount of analyte. The recoveries <br />are an indication of how that sample matrix affects analyte recovery. <br />MSRPD <br />: MS/MSD Relative Percent Difference (RPD) - The MS relative percent difference is an indication of precision for the preparation <br />and analysis. <br />ND <br />: Non -detect - Result was below the DQO listed for the analyte. <br />DQO <br />: Data Quality Objective - This is the criteria against which the quality control data is compared. <br />Corporate Offices & Laboratory Office & Laboratory Office & Laboratory <br />563 E. Undo Avenue 3442 Empresa Drive, Suite D <br />Chico, CA 95926 San Luis Obispo, CA 93401 <br />TEL: (530)343-5818 TEL: (805)783-2940 <br />FAX: (530)343-3807 FAX: (805)783-2912 <br />CA ELAP Certification No. 2670 CA ELAP Certification No. 2775 <br />Office & Laboratory <br />853 Corporation Street <br />2500 Stagecoach Road <br />Santa Paula, CA 93060 <br />Stockton, CA 95215 <br />TEL: (805)392-2000 <br />TEL: (209)942-0182 <br />Env FAX: (805)525-4172 /Ag FAX: (805)392-2063 FAX: (209)942-0423 <br />CA ELAP Certification No. 1573 <br />CA ELAP Certification No. 1563 <br />Page 3 of 3 <br />Office & Laboratory <br />9415 W Goshen Avenue <br />Visalia, CA 93291 <br />TEL: (559)734-9473 <br />FAX: (559)734-8435 <br />CA ELAP Certification No. 2810 <br />