18'-0"GRID LINEELEVATION/SECTION REFERENCE:ELEVATION HEIGHT MARKER:LEVEL NAMESPOT ELEVATION HEIGHT MARKERAD.001SIMDETAIL REFERENCE:DETAIL NUMBERSHEET NUMBERKEYNOTE REFERENCE:SEQUENCE NUMBERCSI DIVISION NUMBERLEVEL8'-0"HEIGHT101101ROOM NAME & REFERENCE NUMBERDOOR REFERENCE NUMBERRATED DOOR REFERENCE NUMBER10 00 30.A2DETAIL NUMBERSHEET NUMBERWALL TYPE REFERENCE NUMBERINTERIOR ELEVATIONDETAIL NUMBERSHEET NUMBERA10.001111ROOMNAME101S1001WINDOW REFERENCE NUMBERSTOREFRONT REFERENCE NUMBERM4.1MATERIAL TYPE (M) MTL, (W) WDMATERIAL WIDTHWALL HEIGHT (SEE ELEV.)1A101ACOUS ACOUSTICALACT ACOUSTICAL CEILING TILEADJ ADJUSTABLEAFF ABOVE FINISH FLOORALT ALTERNATEARCH ARCHITECTB.O. BOTTOM OFBD BOARDBET BETWEENBLKG BLOCKINGBM BEAMBOT BOTTOMBRKT BRACKETBUR BUILT UP ROOFC.G. CORNER GUARDCAB CABINETCALK CAULKINGCER CERAMICCJ CONTROL JOINTCLR CLEARCO CASED OPENINGCOL COLUMNCONT CONTINUOUSCPT CARPETCT CERAMIC TILECTR CENTERCW CHASE WALLDIA DIAMETERDIM DIMENSIONDN DOWNDR DOORDS DOWN SPOUTDWG DRAWING(E) EXISTINGEA EACHELEV ELEVATIONEMER EMERGENCYEOS EDGE OF SLABEQ EQUALEW EACH WAYF.O. FACE OFFA FIRE ALARMFAP FIRE ANNUNCIATOR PANELFD FLOOR DRAINFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFH FIRE HYDRANTFIN FINISHFRP FIBER-REINFORCED PLASTICFS FINISHED SLABFT FOOT OR FEETFUR FURRINGG.S.M. GALVANIZED SHEET METALG/L GRID LINEGAL GALLONGALV GALVANIZEDGB GRAB BARGC GENERAL CONTRACTORGL GLASSGND GROUNDGWB GYPSUM BOARDH.W.H. HOT WATER HEATERHDWD HARDWOODHM HOLLOW METALHT HEIGHTID INSIDE DIAMETERINSUL INSULATIONINT INTERIORJST JOISTJT JOINTLAM LAMINATELAV LAVATORYLDG LANDINGLT LIGHTMEMB MEMBRANEMFR MANUFACTURERMIN MINIMUMMISC MISCELLANEOUSMO MASONRY OPENINGMP METAL PANELMTD MOUNTEDMTL METALNIC NOT IN CONTRACTNO NUMBERNTS NOT TO SCALEO.P. OVERFLOW PIPEOA OVERALLOC ON CENTEROD OUTSIDE DIAMETEROPG OPENINGOPP OPPOSITEPERM PERIMETERPG PAINT GRADEPLAM PLASTIC LAMINATEPLAS PLASTERPR PAIRPT PAINTR RISERRAD RADIUSRCP REFLECTED CEILING PLANRD ROOF DRAINREF REFRIGERATORREINF REINFORCEDREQD REQUIREDRESIL RESILIENTRI RIGID INSULATIONRO ROUGH OPENINGRTU ROOF TOP UNIT (MECH)SAFB SOUND ATTENUATION FIBER BATTSC SCUPPERSCD SEE CIVIL DRAWINGSSCHED SCHEDULESEAL SEALANTSECT SECTIONSED SEE ELECTRICAL DRAWINGSSF SQUARE FOOTSFM STATE FIRE MARSHALSFPD SEE FIRE PROTECTION DRAWINGSSHT SHEETSIM SIMILARSLD SEE LANDSCAPE DRAWINGSSMBD SEE METAL BUILDING DRAWINGSSMD SEE MECHANICAL DRAWINGSSPD SEE PLUMBING DRAWINGSSPEC SPECIFICATIONSPR SINGLE PLY ROOFINGSQ SQUARESS STAINLESS STEELSSD SEE STRUCTURAL DRAWINGSSTD STANDARDSTL STEELSTOR STORAGESUSP SUPSPENDEDSYM SYMMMETRICALT TREADTHK THICKTHR THRESHOLDTO TOP OFTYP TYPICALUNO ULNESS NOTED OTHERWISEUON UNLESS OTHERWISE NOTEDVCT VINYL COMPOSITION TILEVIF VERIFY IN FIELDVTR VENT TERMINATION PIPEVWC VINYL WALL COVERINGW/ WITHW/O WITHOUTWC WATERCLOSETWIN WINDOWWP WATERPROOFWSCT WAINSCOTWT WEIGHTS301 FRAMING ELEVATIONSS302 BUILDING ELEVS & SECTIONSS901 3D VIEWSS902 3D VIEWSS903 3D VIEWSMETAL BUILDING1 GENERAL INFORMATION2 ANCHOR ROD PLAN3 REACTIONS4 ROOF PLAN5 ROOF SUPPORT BEAM PLAN6 SIDEWALL ELEVATIONS7 ENDWALL ELEVATIONS8 CROSS SECTION AT LINES 4-119 GENERAL DETAILS10 GENERAL DETAILSMECHANICALM0 MECHANICAL SCHEDULES, NOTES, AND DETAILSM1.1 MECHANICAL FIRST FLOOR PLANM1.2 MECHANICAL ENLARGED FIRST FLOOR PLANM2 MECHANICAL ROOF PLANT24.1 T-24 ENV AND MECH COMPLIANCE FORMSPLUMBINGP0 PLUMBING SCHEDULES, NOTES AND DETAILSP1.0 PLUMBING FIRST FLOOR AND ROOF PLANSP1.1 PLUMBING ENLARGED FLOOR PLANELECTRICALE0.1 GENERAL NOTESE1.1 ELECTRICAL SITE PLANE2.1 PARTIAL LIGHTING AND ELECTRICAL PLANSE2.2 GYM LIGHTING PLANE2.3 GYM ELECTRICAL PLANE3.1 ELECTRICAL DETAILSSOLARPV-1.0 SITE PLAN, ARRAY PLAN, AND PROJECT NOTESPV-2.0 ARRAY STRING MAPPV-3.0 FIRE LABELS, PV PLACARD AND EQUIPMENT ELEVATION VIEWPV-4.0 SINGLE LINE DIAGRAM AND CALCULATIONSPV-5.0 MANUFACTURES DATA SHEETSGENERALG0.00 COVER SHEET, PROJECT DATA, GENERAL NOTES, SYMBOLS & ABBREVATIONSG1.00 CALGREEN CHECKLISTG1.01 CALGREEN CHECKLISTG1.02 CALGREEN CHECKLISTG2.00 LIFE SAFETY PLANG3.00 SIGNAGE DETAILSG4.00 ACCESSIBILITY STANDARDSG4.01 ACCESSIBILITY DETAILSG5.00 CONDITIONS OF APPROVAL FROM CITY OF MANTECAG5.01 CONDITIONS OF APPROVAL FROM CITY OF MANTECACIVILC1.00 GENERAL NOTESC2.00 CONSTRUCTION DETAILSC3.00 TOPOGRAPHIC SURVEY & DEMOLITION PLANC3.10 TOPOGRAPHIC SURVEY & DEMOLITION PLANC4.00 DIMENSION & STRIPING PLANC4.10 DIMENSION & STRIPING PLANC5.00 GRADING AND DRAINAGE PLANC5.10 GRADING AND DRAINAGE PLANC6.00 UTILITY PLANC6.01 UTILITY PLANC7.00 EROSION CONTROL PLANLANDSCAPEL0.1 COVER SHEETL1.1 SITE CONSTRUCTION PLANL1.2 SITE CONSTRUCTION DETAILSL2.1 SITE CONSTRUCTION DETAILSL3.1 IRRIGATION PLANL3.2 IRRIGATIN PLANL4.1 PLANTING PLANL4.2 PLANTING PLANL5.1 IRRIGATION DETAILSL5.2 IRRIGATION DETAILSL6.1 PLANTING DETAILSL7.1 WELO NOTES AND CALCULATIONSL7.2 LANDSCAPE SPECIFICATIONSL7.3 LANDSCAPE SPECIFICATIONSARCHITECTURALA1.00 SITE PLANA1.01 SITE PLAN DETAILSA3.00 FLOOR DIMENSION PLAN - WESTA3.10 FLOOR DIMENSION PLAN - EASTA3.11 ANNOTATION FLOOR PLAN - WESTA3.12 ANNOATION FLOOR PLAN - EASTA4.00 REFLECTED CEILING PLANA5.00 OVERALL ROOF PLANA6.00 EXTERIOR ELEVATIONSA7.00 BUILDING SECTIONSA7.01 BUILDING SECTIONSA7.10 WALL SECTIONSA8.00 ENLARGED FLOOR PLAN & INTERIOR ELEVATIONSA9.00 FACADE LAYOUTA9.01 DOOR & STOREFRONT SCHEDULEA9.02 ROOM FINISH SCHEDULEAD.01 DETAILSAD.02 DETAILSAD.03 DETAILSAD.04 DETAILSAD.05 DETAILSSTRUCTURALS001 GENERAL NOTES & TYPICAL DETAILSS200 OVERALL FOUNDATION PLANS201 LOBBY FOUNDATION PLAN & DETAILSS202 PEMB FOUNDATION PLAN AND DETAILSS210 LOBBY MECH WELL FRMG PLAN & DETAILSS220 OVERALL RF FRMG PLANS221 LOBBY FR FRMG PLAN & DETAILSS222 PEMB ROOF FRMG PLANREFERENCEDESCRIPTIONINTERPRETATIONDESCRIPTIONSCOPENEW METAL BUILDINGGYMNASIUM WITH ADDITIONALSTRUCTURE THAT INCLUDESLOBBY, OFFICES, SNACK BARAND EVENT ROOMLOCATION450 COMMERCE COURTMANTECA, CAZONINGM-2 / BIPAPN221-250-13GENERAL INFORMATIONCBC 303.5 GROUP A-4 FLOOR AREA 21,000 SFCBC TABLE 506.2 ALLOWABLE BUILDING AREA 24,000 SFACTUAL BUILDING HEIGHT 36'-0"CBC TABLE 504.3 ALLOWABLE BUILDINGHEIGHT60'-0"ACTUAL NUMBER OF STORIES 1 STORYCBC TABLE 504.4 ALLOWABLE NUMBER OFSTORIES2OCCUPANT LOAD 412CBC 303.5 GROUP B FLOOR AREA 4,512 SFCBC TABLE 506.2 ALLOWABLE BUILDING AREA 36,000 SFACTUAL BUILDING HEIGHT 29'-0"CBC TABLE 504.3 ALLOWABLE BUILDINGHEIGHT60'-0"ACTUAL NUMBER OF STORIES 1 STORYCBC TABLE 504.4 ALLOWABLE NUMBER OFSTORIES3OCCUPANT LOAD 159TOTAL BUILDING AREA 25,512 SFTOTAL OCCOPANT LOAD 571OCCUPANCYCBC 508.3 AUTOMATIC FIRESPRINKLERSYESCBC TABLE 601 CONSTRUCTION TYPE V-BMACHADO SPORTS PARK450 COMMERCE COURT, MANTECA, CAADDRESS:PHONE:CONTACT:EMAIL:Bruno Machado1020 Marsh CreekManteca, CA. 95336ebmainvestments@gmail.comOWNER:ADDRESS:PHONE:CONTACT:EMAIL:JH Lawder717 16th Street, Suite 4Modesto, CA. 95354209.521.1143John Lawderjohn@jhlawderse.comSTRUCTURAL ENGINEER:ADDRESS:PHONE:CONTACT:EMAIL:MID-CAL2716 E. Miner Ave.Stockton, CA. 95205Brent Collinsbrent@midcalconstructors.comCONTRACTOR:ADDRESS:PHONE:CONTACT:EMAIL:GDMD Engineering, Inc.212 W. Pine St. Ste. 4Lodi, CA. 95242209.367.0899Eric G. Davisgdmdengrinc@sbcglobal.netMECHANICAL ENGINEER:ADDRESS:PHONE:CONTACT:EMAIL:MCR Engineering1242 Dupont CourtManteca, CA. 95336209.239.6229Shawn Samaniegoshawn@mcrfeng.comCIVIL ENGINEER:ADDRESS:PHONE:CONTACT:EMAIL:LDA Partners, LLP222 Central Ct.Stockton, CA. 95204209.943.0405Eric Wohleewohle@ldapartners.comARCHITECT:ADDRESS:PHONE:CONTACT:EMAIL:HCS Engineering4512 Feather River Dr.Stockton, CA. 95219209.478.8270Richard Smithrichard@hcs-eng.comELECTRICAL ENGINEER:ADDRESS:PHONE:CONTACT:EMAIL:GDMG Engineering, Inc.212 W. Pine St. Ste. 4Lodi, CA,95242209.367.0899Eric G. Davisgdmdengrinc@sbcglobal.netPLUMBING ENGINEER:PLAN CHECK SUBMITTALJUNE 02, 2021GENERAL NOTESCONTACTSPROJECT DATASHEET INDEXAPPLICABLE CODESSYMBOLS LEGENDABBREVIATIONSFALIOFCSeptember 2021SS T A TEERIILCWCENH OC28388AIRNL EWOITARCHEDAILLIMECT Checked By:Drawn By:Project No.:LDA Partners, Inc.Designers & Architects222 Central CourtStockton, CA 95204209.943.0405www.ldapartners.comClient:Project:Architect:450 COMMERCE COURT,MANTECA, CA. 953366/3/2021 5:08:04 PMCOVER SHEET, PROJECT DATA,GENERAL NOTES, SYMBOLS &ABBREVATIONSG0.00DVEW727-01-18PERMIT SUBMITTAL #206/02/2021MACHADO SPORTS PARK1020 MARSH CREEKEBMA INVESTMENTSMANTECA, CA 953361. ON-SITE VERIFICATION OF ALL DIMENSIONS AND DETAILS SHALL BE THERESPONSIBILITY OF THE GENERAL CONTRACTOR AND EACHSUBCONTRACTOR FOR HIS INDIVIDUAL WORK. THE OWNER OR ARCHITECTSHALL BE NOTIFIED IF ANY DISCREPANCIES ARE FOUND PRIOR TOCOMMENCING ANY WORK. THE RESPONSIBILITY FOR WORK COMPLETEDWITHOUT PROPER NOTIFICATION SHALL BE BORNE BY THE INDIVIDUALCONTRACTOR INVOLVED.2. THE CONTRACT DOCUMENTS INDICATE THE EXTENT AND APPROXIMATELOCATION OF ELEMENTS OF THE BUILDING AND SITE. ALL CONDITIONS,LOCATIONS, DEVICES AND ELEMENTS SHALL BE VERIFIED BY THECONTRACTOR PRIOR TO COMMENCING THE WORK.3. ALL WORK PERFORMED IN CONNECTION WITH THESE CONTRACT DOCUMENTSSHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (ADA), ALLAPPLICABLE STATE AND LOCAL CODES, ORDINANCES, AND ZONINGREGULATIONS IN EFFECT AT THE TIME OF CONSTRUCTION. THIS PROJECTSHALL COMPLY WITH TITLE 24, 2019 CBC, CMC, CPC, CFC, CEC BASED ON THE2019 CALIFORNIA ENERGY STANDARDS.4. IT SHALL BE UNDERSTOOD THAT THE INTENT OF THESE CONSTRUCTIONDOCUMENTS IS TO CONSTRUCT THE FACILITY IN ACCORDANCE WITH THEAPPLICABLE CODES AND ORDINANCES. SHOULD ANY CONDITION BEUNCOVERED OR DEVELOP DURING THE EXECUTION OF THESE DOCUMENTS,WHICH IS NOT DEFINED HEREIN, THE CONTRACTOR SHALL CEASE WORK ANDNOTIFY THE ARCHITECT AT ONCE.5. THE TYPICAL DETAILS SHOWN IN THESE PLANS SHALL APPLY IN ALLSIMILAR CASES UNLESS SPECIFICALLY NOTED OTHERWISE. WHERE NODETAIL IS SHOWN, CONSTRUCTION SHALL BE AS INDICATED FOR OTHERSIMILAR WORK AND, OR APPLICABLE INDUSTRY PRACTICE.6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION OFINSTALLATION, INSPECTION, AND FINAL APPROVAL OF ALL UTILITIES.7. VERIFY ALL DIMENSIONS, EXISTING CONDITIONS, AND METHODS OFCONSTRUCTION PRIOR TO START OF ANY WORK. NOTIFY THE ARCHITECTOF ANY DISCREPANCIES.8. IT IS NOT THE INTENT OF THESE CONTRACT DOCUMENTS TO SEPARATE THEWORK INTO SUBTRADE DIVISIONS. IT SHALL BE THE RESPONSIBILITY OFTHE GENERAL CONTRACTOR TO DIVIDE THE WORK AND ORGANIZE ALLWORK AS REQUIRED TO COMPLETE THE WORK AS INTENDED BY THESEDOCUMENTS.9. SITE DEVELOPMENT AND GRADING SHALL PROVIDE ACCESS TO PRIMARYENTRANCES AND NORMAL PATHS OF TRAVEL, AND SHALL INCORPORATEPEDESTRIAN RAMPS, CURB RAMPS, ETC. ALL RAMPS SHALL HAVE A MAXIMUMSLOPE OF 1:12, OR AS NOTED ON THESE CONSTRUCTION DOCUMENTS. ANYPATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF IT'S SLOPE ISGREATER THAN 1 FT. RISE IN 20 FT. RUN (5%)10. EACH PARKING FACILITY WHERE PARKING IS PROVIDED FOR THE PUBLIC,GUESTS OR EMPLOYEES SHALL PROVIDE ACCESSIBLE PARKING ANDLOADING STALLS DESIGNATED SPECIFICALLY FOR HANDICAPPED PERSONS.11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATIONOF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO THE COMMENCEMENT OF WORK. HE SHALL BE RESPONSIBLE FOR THE LOCATION ANDPRESERVATION OF ALL SUCH FACILITIES IN THE AREA OF CONSTRUCTION, AND SHALL NOTIFY UTILITY COMPANIES 48 HOURS IN ADVANCE OF ANYCONSTRUCTION (UNDERGROUND SERVICE ALERT 1-800-227-2600)12. EACH PARKING SPACE RESERVED FOR PERSONS WITH PHYSICALDISABILITIES SHALL BE IDENTIFIED BY A REFLECTORIZED SIGNPERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROMEACH STALL OR SPACE, CONSISTING OF A PROFILE VIEW OF A WHEELCHAIROCCUPANT IN WHITE ON A BLUE BACKGROUND. THE SIGN SHALL NOT BESMALLER THAN 70 SQ. IN. IN AREA AND, WHEN POSTED IN A PATH OFTRAVEL, SHALL BE A MINIMUM HEIGHT OF 80 INCHES FROM THE BOTTOM OFTHE SIGN TO THE PARKING SPACE FINISH GRADE, UON. IN ADDITION, ASIGN, AS SPECIFIED IN TITLE 24 ACCESSIBILITY STANDARDS, SHALL BEPOSTED IN A CONSPICUOUS PLACE, AT EACH ENTRANCE TO OFF-STREETPARKING FACILITIES, OR IMMEDIATELY ADJACENT TO AND VISIBLE FROMEACH STALL OR SPACE. SAID SIGNS SHALL BE NOT LESS THAN 17 INCHES X22 INCHES IN SIZE WITH LETTERING NOT LESS THAN 1 INCH HIGH.13. PROVIDE A CLEAR AND LEVEL LANDING ON EACH SIDE OF AN EXIT DOOR.THE LANDING SHALL BE 48 INCHES IN LENGTH WHERE THE DOOR SWINGSAWAY FROM THE LANDING, AND 60 INCHES IN LENGTH IN THE DIRECTIONOF DOOR SWING AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THEDOOR IN THE CLOSED POSITION.14. GENERAL DEMOLITION: WHENEVER EXISTING FACILITIES OR MATERIALSARE REMOVED, DAMAGED, BROKEN, OR CUT IN THE INSTALLATION OF WORKCOVERED BY THE DRAWINGS AND SPECIFICATIONS, SAID FACILITIES ANDMATERIALS SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. SAIDFACILITIES OR MATERIALS SHALL BE EQUAL TO OR BETTER THAN THEORIGINAL FACILITIES OR MATERIALS. THE FINISH PRODUCT SHALL BESUBJECT TO THE APPROVAL OF THE COUNTY AND ITS AGENTS.15. NO WORK SHALL COMMENCE AT THE PROJECT SITE BEFORE A BUILDINGPERMIT IS FULLY EXECUTED AND AVAILABLE FOR POSTING AT THE JOBSITE.16. CONSTRUCTION LIMITS: CONTRACTOR AND SUB-CONTRACTORS, WORKERSAND OTHER PERSONNEL RELATED TO THIS SCOPE OF WORK, SHALL BECONFINED WITH THE AREAS DESIGNATED AS CONSTRUCTION LIMITS ASINDICATED BY THESE DRAWINGS AND RELATED AREAS. AREAS BEYONDTHIS SCOPE OF WORK SHALL BE OFF LIMITS, AND THEIR USE SHALL BEPROHIBITED WITHOUT PRIOR AUTHORIZATION OF THE CITY OF MANTECA.THE GENERAL CONTRACTOR SHALL VERIFY THESE LIMITS AND BERESPONSIBLE TO INFORM THE APPROPRIATE PERSONNEL AND ENFORCETHESE LIMITS.17. PROVIDE CONTINUOUS 16GA. X REQUIRED WIDTH (6" MIN.) FLAT BACKINGSTRAP AT WALLS WITH WALL MOUNTED EQUIPMENT, CASEWORK, AND/ORACCESSORIES - TYPICAL UNLESS OTHERWISE NOTED.18. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACTDOCUMENTS AND THE EXISTING FIELD CONDITIONS, AND SHALL AT ONCEREPORT TO THE ARCHITECT ANY ERROR, INCONSISTENCY, OR OMISSION HEMAY DISCOVER. THE CONTRACTOR SHALL PERFORM NO PORTION OF THEWORK AT ANY TIME WITHOUT APPROVED CONTRACT DOCUMENTS OR WHEREREQUIRED, APPROVED SHOP DRAWINGS, PRODUCT LITERATURE, DATA,SAMPLES OR INSTALLATION INSTRUCTIONS.19. THE CONTRACTOR SHALL OBTAIN AN ENCROACHMENT PERMIT, WHEREAPPLICABLE, FOR ANY WORK DONE WITHIN THE RIGHT-OF-WAY OREASEMENTS FROM THE AUTHORITY HAVING JURISDICTION. THECONTRACTOR SHALL NOTIFY THE OWNER 48 HOURS IN ADVANCE OFCOMMENCEMENT OF THE WORK OR AS REQUIRED BY SAID PERMITS.20 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING, ORPATCHING THAT MAY BE REQUIRED TO COMPLETE THE INTENT OF THESECONSTRUCTION DOCUMENTS, TO MAKE IT'S SEVERAL PARTS FIT TOGETHERPROPERLY. THE CONTRACTOR SHALL PATCH ARCHITECTURAL FINISHES ASNECESSARY TO ACCOMPLISH WORK DEFINED IN STRUCTURAL, MECHANICAL,PLUMBING, ELECTRICAL, AND ARCHITECTURAL DRAWINGS. EXISTING FIELDCONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR AND ACCEPTED ASCONDITIONS OF THIS SCOPE OF WORK.21. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH PG&E AND/ORSERVICE PROVIDER FOR ANY NEW SERVICE INSTALLATIONS. THECONTRACTOR SHALL COORDINATE THE SHUT DOWN OF THE FACILITIES WITHTHE OWNER FOR AS MINIMAL DURATION AS POSSIBLE. INTERCEPT THEEXISTING SERVICE CONDUIT, EXTEND IT TO NEW TRANSFORMERS AND PAD(TO BE INSTALLED BY CONTRACTOR) AND EXTEND SECONDARY CONDUITSTO THE NEW SWITCHBOARD. COORDINATE WITH THE OWNER TO VERIFYLOCATION, PROVIDE TRAFFIC BARRIER POSTS PER PG&E REQUIREMENTS.22. CONTRACTOR SHALL FLUSH ALL WATER, SEWER, AND DRAIN LINES PRIOR TOHOOK UP.23. DIMENSIONS SHALL BE MEASURED TO FACE OF FRAMING, U.O.N.24. PROVIDE 2% SLOPE AWAY FROM THE BUILDING FOR 10'-0" AT FRONT ANDSIDES.25. NO DRAINAGE ACROSS OR ONTO ADJACENT PROPERTY. PROVIDE 2% SLOPEAWAY FROM THE BUILDING FOR 10'-0" AT FRONT AND SIDES.26. DO NOT SCALE THE DRAWINGS.27. SUBSTITUTIONS OR CHANGES AFFECTING THE APPROVED DRAWINGS,SPECIFICATIONS OR DSA REGULATED ITEMS SHALL BE MADE BY ADDENDAOR SUBMITTED AS; DSA 140 APPLICATION FOR APPROVAL OFCONSTRUCTION CHANGE DOCUMENT - CCD CATEGORY A/B, AS PER SECTION4-338, PART 1 TITLE 24, CCR, AND INTERPRETATION OF REGULATION (IR)A-6.PROJECT LOCATIONVICINITY MAPDEFERRED APPROVALS1. FIRE SPRINKELR PLANS2. FIRE ALARM PLANSADDRESS:PHONE:CONTACT:EMAIL:Sam Harned Landscape ArchitectureP.O. Box 2275Oakdale, CA. 95361209.380.7376Sam Harnedsam@harnedla.comLANDSCAPE ARCHITECT:TITLE 19 CCR, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONSTITLE 24 CCR, PART 1 - 2019 BUILDING STANDARDS ADMINISTRATIVE CODETITLE 24 CCR, PART 2 - 2019 CALIFORNIA BUILDING CODE, VOL. 1 & 2 (CBC)(2015 IBC, AS AMENDED BY CA)TITLE 24 CCR, PART 3 - 2019 CALIFORNIA ELECTRICAL CODE (CEC) (2014 NEC,AS AMENDED BY CA)TITLE 24 CCR, PART 4 - 2019 CALIFORNIA MECHANICAL CODE (CMC) (2015IAPMO UMC, AS AMENDED BY CA)TITLE 24 CCR, PART 5 - 2019 CALIFORNIA PLUMBING CODE (CPC) (2015 IAPMOUPC, AS AMENDED BY CA)TITLE 24 CCR, PART 6 - 2019 CALIFORNIA ENERGY CODETITLE 24 CCR, PART 9 - 2019 CALIFORNIA FIRE CODE (CFC) (2015 IFC, ASAMENDED BY CA)TITLE 24 CCR, PART 11 - 2019 CALIFORNIA GREEN BUILDING STANDARDS CODETITLE 24 CCR, PART 12 - 2019 CALIFORNIA REFERENCED STANDARDS (PARTIALLIST - SEE CBC CH. 35 AND CFC CH. 80)2016 NFPA 13, INSTALLATION OF SPRINKLER SYSTEMS (CA AMENDED)2013 NFPA 14, INSTALLATION OF STANDPIPE AND HOSE SYSTEMS2013 NFPA 17, DRY CHEMICAL EXTINGUISHING SYSTEMS2013 NFPA 17A, WET CHEMICAL EXTINGUISHING SYSTEMS2016 NFPA 20, INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION2013 NFPA 22, WATER TANKS FOR PRIVATE FIRE PROTECTION2016 NFPA 24, INSTALLATION OF PRIVATE FIRE SERVICE MAINS2016 NFPA 72, NATIONAL FIRE ALARM CODE (CA AMENDED); SEE UL STD. 1971FOR "VISUAL DEVICES"2016 NFPA 80, FIRE DOOR AND OTHER OPENING PROTECTIVES2015 NFPA 2001, CLEAN AGENT FIRE EXTINGUISHING SYSTEMS2005 UL 300, CLASS I HOOD FIRE SUPPRESSION SYSTEMS2003 UL, 464, AUDIBLE SIGNAL APPLIANCES1999 UL 521, HEAT DETECTORS FOR FIRE PROTECTIVE SIGNALING SYSTEMSPLUMBING FIXTURE COUNTOCCUPANCY/USEAREAOCC. LOADFACTOROCC.LOADWATER CLOSETSLAVATORIESURINALSDRINKING FOUNTAINSREQUIREDPROVIDEDREQUIREDPROVIDEDREQUIREDPROVIDEDREQUIREDPROVIDEDMALEFEMALEMALEFEMALEMALEFEMALEMALEFEMALEGYMNASIUM,OFFICE, SNACKS, LOBBY, EVENT ROOM 21742 SF1/30 725 3 8 3 8 2 5 4 5 3 4 3 4111No. Description Date By1 PLAN CHECK #1 05-05-2021DV2 PLAN CHECK #2 06-02-2021DV222NOTE:PER TABLE A OF PLUMBING CODE 422.1 - EXCLUDES ACCERSSORY SPACES (LOBBY, RESTROOMS, STORAGE, JANITOR, IT ROOM, FIRE RISER AND ELECTRICAL ROOM)OCCUPANT -LOADROOMNO.ROOM NAMEOCCUPANCYAREALOADFACTOROCC.LOADA101 LOBBY B 1404 SF 15 SF 94A102 OFFICE 2 B 132 SF 150 SF 1A103 OFFICE 1 B 132 SF 150 SF 1A104 SNACKS B 260 SF 150 SF 2A105 EVENT ROOM B 807 SF 15 SF 54A107 MEN'S B 317 SF 0 SFA108 WOMEN'S B 321 SF 0 SFA109 STORAGE B 511 SF 300 SF 2A110 ELECT. RM. B 108 SF 300 SF 1A112 JNTR. B 42 SF 300 SF 1A113 STRG. B 43 SF 300 SF 1A114 WOMEN'S R.R. B 51 SF 0 SFA115 FIRE RISER RM. B 32 SF 300 SF 1A116 I.T. RM. B 20 SF 150 SF 1A122 GYMNASIUM A-4 20411 SF 50 SF 409E3.1 ELECTRICAL DETAILSET24A COMPLIANCEE3.1 ELECTRICAL DETAILSET24A COMPLIANCEET24B COMPLIANCEE3.1 ELECTRICAL DETAILSET24A COMPLIANCEET24B COMPLIANCE409568159568SEE SHEET S001 FOR THE LIST OF REQUIREDSPECIAL INSPECTIONS.26,040 SFCommissioning Plan complying with CGBSC 5.410.2 including all of thefollowing shall be submitted prior to Foundation Inspection to Cityof Manteca:1. Owner’s or owner representative’s projectrequirements.2. Basis of design.3. Commissioning measures shown inthe construction documents.4. Commissioning plan.5. Functionalperformance testing.6. Documentation and training.7. Commissioningreport6/3/2021, 10:45:51 AM21-0396Mallorie Fenrich5/18/2021, 8:33:39 AM21-0396Roseville Submittals5/26/2021, 5:09:20 PM21-0396Maribel Serrano6/8/2021, 1:58:25 PM21-0396LUMEN ARCEOSan Joaquin County Environmental Health Department 1868 E. Hazelton Ave. Stockton, CA 95205 (209) 468-3420 APPROVED WITH CONDITIONS For conditions, please see approval letter dated: Approved by:_______________________Date:_______________ 3-17-22Mar 17, 2022 Gehane Fahmy
|