Laserfiche WebLink
A <br />AB ANCHOR BOLT <br />ADJ ADJACENT <br />ALT ALTERNATE <br />ARCH ARCHITECT <br />B <br />BLDG BUILDING <br />BLKG BLOCKING <br />BM BM <br />BOTT BOTTOM <br />BOW BOTTOM OF WALL <br />BTWN BETWEEN <br />C <br />ñ CENTERLINE <br />CLR CLEAR <br />COL COLUMN <br />CONC CONCRETE <br />CONN CONNECTION <br />CONT CONTINUOUS <br />COV COVER <br />CP COMPLETE <br />PENETRATION <br />D <br />D/B DESIGN/BUILD <br />DBL DOUBLE <br />DEMO’D DEMOLISH/ <br />DEMOLITION <br />DIAG DIAGONAL <br />DIAPH DIAGRAM <br />DN DOWN <br />do DITTO <br />DWG DRAWING <br />E <br />EA EACH <br />ELEV ELEVATION <br />EN EDGE NAIL(ING) <br />EOD EDGE OF DECK <br />EQ EQUAL <br />EXP EXPANSION <br />EXT EXTERIOR <br />F <br />FIN FINISH <br />FLG FLANGE <br />FLR FLOOR <br />FOS FACE OF STUD <br />FRMG FRAMING <br />FTG FOOTING <br />G <br />GA GAGE, GAUGE <br />GEOM GEOMETRY <br />GL GRID LINE <br />H <br />HDR HEADER <br />HK HOOK <br />HOIRZ HORIZONTAL <br />HT HEIGHT <br />I <br />ID INSIDE DIAMETER <br />J <br />JS JACK STUD <br />JST JOIST <br />JT JOINT <br />K <br />(K) KING <br />L <br />L ANGLE <br />LLH LONG LEG <br />HORIZONTAL <br />LLV LONG LEG <br />VERTICAL <br />LOC LOCATION <br />LT GA LIGHT GAGE <br />LT WT LIGHT WEIGHT <br />M <br />MAX MAXIMUM <br />MBF METAL BLDG MFR <br />MECH MECHANICAL <br />MFR MANUFACTURER <br />MIN MINIMUM <br />MTL METAL <br />N <br />NO. NUMBER <br />NOM NOMINAL <br />NS/NM NON-SHRINK/ <br />NON-METALLIC <br />O <br />o/ OVER <br />O.C. ON CENTER <br />OD OUTSIDE <br />DIAMETER <br />OPNG OPENING <br />P <br />ð PLATE <br />PDF POWDER DRIVEN <br />FASTENER <br />PROJ PROJECTION <br />PT PRESSURE <br />TREATED <br />PW PUDDLE WELD <br />R <br />R RADIUS <br />REINF REINFORCEMENT <br />REQ('D) REQUIRE(D) <br />S <br />SC SOFT CUT <br />SCHED SCHEDULE <br />SHTG SHEATHING <br />SIM SIMILAR <br />SOG SLAB ON GRADE <br />SQ SQUARE <br />STD STANDARD <br />STIFF STIFFENER <br />SYM SYMMETRICAL <br />T <br />TB TIE BEAM <br />T&B TOP & BOTTOM <br />THK THICKNESS <br />THRD THREADED <br />THRU THROUGH <br />TJ TOOLED JOINT <br />TOC TOP OF <br />CONCRETE <br />TOF TOP OF FRAMING <br />TOS TOP OF STEEL <br />TOW TOP OF WALL <br />TYP TYPICAL <br />U <br />UON UNLESS <br />OTHERWISE <br />NOTED <br />V <br />VERT VERTICAL <br />W <br />WHS WELDED HEAD <br />STUD <br />w/ WITH <br />w/o WITHOUT <br />1.ADHESIVE TO BE EITHER OF THE FOLLOWING: <br />A. CONCRETE BASE MATERIAL: <br />1) HILTI HIT-RES 500-SD ADHESIVE ANCHOR SYSTEM AS MANUFACTURED BY HILTI, INC. <br />INSTALLED IN ACCORDANCE WITH ICC REPORT ESR-2322. <br />2) SET-XP EPOXY ADHESIVE ANCHOR SYSTEM AS MANUFACTURED BY SIMPSON <br />STRONG-TIE COMPANY, INC. INSTALLED IN ACCORDANCE WITH ICC REPORT ESR-2508. <br />B. CMU BASE MATERIAL: <br />1) HILTI HIT-HY 70 ADHESIVE ANCHOR SYSTEM AS MANUFACTURED BY HILTI, INC. <br />INSTALLED IN ACCORDANCE WITH ICC REPORT ESR-2682. <br />2) SET-XP EPOXY ADHESIVE ANCHOR SYSTEM AS MANUFACTURED BY SIMPSON <br />STRONG-TIE COMPANY, INC. INSTALLED IN ACCORDANCE WITH IAPMO REPORT 265. <br />2. HOLES MUST BE DRILLED USING A DRILL THAT IS SET IN ROTATION-AND-HAMMERING MODE <br />THAT HAS A CARBIDE-TIPPED DRILL BIT THAT COMPLIES WITH ANSI B212.15. <br />3. HOLES MUST BE CLEANED OF DUST AND DEBRIS, USING THE MANUFACTURER'S <br />RECOMMENDED WIRE BRUSH AND OIL FREE COMPRESSED AIR TO REMOVE PARTICULATE <br />DEBRIS AND TO ACHIEVE A RELATIVELY DUST-FREE ADHESIVE CONTACT SURFACE. HOLES <br />ARE PERMITTED TO BE DAMP BUT ALL STANDING WATER MUST BE REMOVED IN <br />ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTRUCTIONS. <br />4. SPECIAL INSPECTION OF ANCHORS/DOWELS MAYBE EITHER OF THE FOLLOWING: <br />A. FULL TIME OBSERVATIONS - SPECIAL INSPECTOR TO RECORD STRENGTH AND AGE OF <br />BASE MATERIAL; DRILL BIT COMPLIANCE WITH ANSI B212-15; HOLE DIAMETER, DEPTH, <br />AND CLEANLINESS; HOLE EDGE DISTANCE AND SPACING; INSTALLATION TEMPERATURE; <br />ADHESIVE PRODUCT DESCRIPTION, INCLUDING PRODUCT NAME; ADHESIVE EXPIRATION <br />DATE; ADHESIVE MIXING PROCEDURE; USE OF PROPER NOZZLES; VERIFICATION OF <br />PROPERLY MIXED ADHESIVE PRIOR TO INJECTION OF ADHESIVE IN ANCHOR HOLE; <br />ANCHORS UNDISTURBED DURING GEL TIME; ROD TYPE, GRADE, DIAMETER, LENGTH, AND <br />CLEANLINESS; AND VERSIFICATION OF ANCHOR INSTALLATION IN ACCORDANCE WITH THE <br />MANUFACTURER'S PUBLISHED INSTRUCTIONS AND ESR REPORT. <br />B. PROOF LOAD PULL TEST - ANCHOR DOES NOT EXHIBIT OBSERVABLE MOVEMENT AT THE <br />APPLICATION OF PROOF LOAD, I.E., WASHER UNDER THE NUT DOES NOT BECOME LOOSE. <br />5. ANCHOR MATERIALS: <br />A. THREADED RODS SHALL BE ASTM F1554, GRADE 36 EXCEPT SHALL BE ASTM A193, <br />GRADE B6 OR BM STAINLESS STEEL FOR EXTERIOR APPLICATIONS. <br />B. DOWELS SHALL BE ASTM A615, GRADE 60. <br />1.GENERAL <br />A. THE STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE 2019 EDITION OF THE <br />CALIFORNIA BUILDING CODE (CBC). <br />B. THE WOOD FRAMED STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING <br />LOADS: <br />1) VERTICAL LOADS: <br />A)ROOF LIVE LOADS - 20 PSF, REDUCIBLE IN ACCORDANCE WITH CBC <br />1607.12.2. <br />B)ROOF DEAD LOADS - AS REQUIRED. <br />2) WIND - IN ACCORDANCE WITH ASCE 7-16 CHAPTERS 26 THROUGH 30 WITH 93 <br />MPH ULTIMATE DESIGN WIND SPEED, 72 MPH ASD WIND SPEED, EXPOSURE C, <br />RISK CATEGORY II, +/- 0.18 INTERNAL PRESSURE COEFFICIENT, AND Kzt= 1.00. <br />3) SEISMIC - ASCE 7-16 EQUIVALENT LATERAL FORCE ANALYSIS WITH RISK <br />CATEGORY II, SITE CLASS D, SEISMIC CATEGORY D, Ss= 0.760, S1= 0.291, SDS= <br />0.606, SD1= 0.485, R=6.5 (WOOD LIGHT FRAMED WOOD SHEATHED SHEAR <br />WALLS), AND CS= 0.093 FOR THE NS AND EW DIRECTIONS. BASE SHEARS ARE <br />13.2 KIPS AND 11.7 KIPS IN THE ns AND EW DIRECTIONS, RESPECTIVELY. <br />C. PEMB <br />1) THE STRUCTURAL DESIGN AND CONSTRUCTION DOCUMENTS ARE BY THE <br />PEMB MANUFACTURER. SEE THE PEMB DRAWINGS FOR THE DESIGN CRITERIA. <br />2) THE FOUNDATIONS AND ANCHOR BOLTS FOR THE PEMB SHOWN ON THESE <br />DRAWINGS IS BASED ON REACTIONS PROVIDED BY THE PEMB MANUFACTURER. <br />D. FOUNDATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH “GEOTECHNICAL <br />ENGINEERING INVESTIGATION, PROPOSED MACHADO SPORTS COMPLEX, 450 <br />COMMERCE COURT, MANTECA, CALIFORNIA" PREPARED BY KRAZAN & <br />ASSOCIATES, INC. GEOTECHNICAL ENGINEERING DIVISION, 448 MITCHELL ROAD, <br />SUITE C, MODESTO, CALIFORNIA 95354, (209) 572-2200. KA PROJECT NUMBER: <br />072-19074, DATED 2/4/20. ALLOWABLE BEARING PRESSURES ARE 2,500 PSF <br />FOR DL + LL WITH 1/3 INCREASE FOR LATERAL LOADS. <br />E. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ADEQUATE <br />BRACING AND SUPPORT OF ALL TEMPORARY CONSTRUCTION AND PARTIALLY <br />COMPLETED PORTIONS OF THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR <br />PROTECTION OF ADJACENT PAVED SURFACES, UTILITIES AND STRUCTURES. <br />F. THE WORK SHALL CONFORM TO THESE NOTES AND DRAWINGS. NO CHANGES <br />SHALL BE ALLOWED WITHOUT WRITTEN AUTHORITY FROM THE ARCHITECT. <br />G. SLAB ON GRADE AND WATER VAPOR TRANSMISSION -VAPOR BARRIER AND <br />DRAINAGE BASE PER GEOTECHNICAL REPORT. VAPOR BARRIER SPECIFICATION <br />AND LOCATION ARE IN ACCORDANCE WITH ACI 302. IT IS NOTED THAT NO <br />GUARANTEE IS PROVIDED OR ASSURANCE IS GIVEN THAT SLAB ON GRADE SYSTEM <br />(DRAINAGE BASE, VAPOR BARRIER, AND SLAB THICKNESS AND REINFORCEMENT) <br />AS SHOWN ON THESE DRAWINGS WILL REDUCE MOISTURE OR MOISTURE VAPOR <br />TRANSMISSION TO ANY SPECIFIC LEVELS OR RATES TO INHIBIT MOLD GROWTH OR <br />NOT ADVERSELY EFFECT MOISTURE-SENSITIVE FLOORING. IF SPECIFIC LEVELS OR <br />RATES ARE TO BE ACHIEVED, THEN A QUALIFIED CONSULTANT SHOULD BE <br />RETAINED TO PROVIDE RECOMMENDATIONS. <br />2. EARTHWORK <br />A. EARTHWORK SHALL BE IN ACCORDANCE WITH THE PROJECT SOILS REPORT. <br />B. SLAB ON GRADE: <br />1) SHALL HAVE A 3 INCH THICK COMPACTED DRAINAGE BASE WITH 15 MIL <br />VAPOR BARRIER OVER PREPARED SUBGRADE AS FOLLOWS: <br />A)VAPOR BARRIER SHALL BE STEGO WRAP VAPOR BARRIER (15-MIL) BY <br />STEGO INDUSTRIES LLC, (877) 464-7834, WWW.STEGOINDUSTRIES.COM OR <br />APPROVED EQUAL. VAPOR BARRIER SHALL BE ASTM E1785, CLASS A <br />EXCEPT SHALL HAVE A PERMEANCE OF LESS THAN 0.01 PERMS AND <br />MAINTAIN PERMEANCE OF LESS THAN 0.01 PERMS AFTER MANDATORY <br />CONDITIONING TESTS PER ASTM E 154 SECTIONS 8,11,12, AND 13. <br />B)DRAINAGE BASE SHALL BE CLEAN. WASHED ROCK GRADED SO THAT 100% <br />PASSES 1" SIEVE AND LESS THAN 5% PASSES NO. 4 SIEVE. DRAINAGE BASE <br />SHALL BE GRADED TO REQUIRED ELEVATION, WITHIN A TOLERANCE OF <br />+1/4 INCH TO -1/2 INCH. COMPACT DRAINAGE BASE AS DIRECTED BY SOILS <br />ENGINEER. IT IS RECOMMENDED THAT THE DRAINAGE BASE BE NATURAL, <br />ROUNDED AGGREGATES INSTEAD OF ANGULAR WITH SHARP EDGES AS IS <br />THE CASE WITH CRUSHED AGGREGATES TO MINIMIZE THE AMOUNT OF <br />REPAIRS TO THE VAPOR BARRIER RESULTING FROM PUNCTURES. <br />2) AFTER DRAINAGE BASE IS COMPACTED PLACE VAPOR BARRIER. VAPOR <br />BARRIER TO BE PLACED IN ACCORDANCE WITH ASTM E1643. LAP VAPOR <br />BARRIER JOINTS 6" MINIMUM AND TAPE WITH TAPE AS RECOMMENDED BY <br />MANUFACTURER. ALL PENETRATIONS (ELECTRICAL AND COMMUNICATIONS <br />CONDUITS, PLUMBING, ETC.) TO BE SEALED AND MADE MOISTURE RESISTANT <br />AS RECOMMENDED BY MANUFACTURER. VAPOR BARRIER SHALL BE TURNED <br />DOWN 12" MINIMUM AT FOOTING SIDES. <br />C. ALL EXCAVATIONS AND APPROVED EARTHWORK SHALL BE PROTECTED FROM <br />WEATHER AND WATER ACCUMULATION AT ALL TIMES. <br />D. ANY PROPOSED DEVIATIONS FROM THE ABOVE EARTHWORK REQUIREMENTS <br />SHALL HAVE THE SOIL ENGINEER'S PRIOR WRITTEN APPROVAL. <br />3. CONCRETE <br />A. CONCRETE MIX DESIGNS: <br />1) FOOTINGS AND INTERIOR SLABS ON GRADE: 3,000 PSI 28 DAY <br />COMPRESSIVE STRENGTH MADE WITH 1" ASTM C33 AGGREGATES (145 PCF <br />MINIMUM DENSITY) AND CONTAIN MINIMUM OF 5.75 SACKS OF CEMENT PER <br />CUBIC YARD WITH A 0.50 MAXIMUM WATER/CEMENT RATIO AND PLACED AT A <br />5" MAXIMUM SLUMP. <br />2) EXTERIOR SLABS ON GRADE, CURBS, & GUTTERS: 2,500 PSI 28 DAY <br />COMPRESSIVE STRENGTH MADE WITH 1" ASTM C33 AGGREGATES AND <br />CONTAIN MINIMUM OF 5.0 SACKS OF CEMENT PER CUBIC YARD WITH A 0.60 <br />MAXIMUM WATER/CEMENT RATIO AND PLACED AT A 5" MAXIMUM SLUMP. <br />B. CEMENT SHALL BE ASTM C150, TYPE I OR II. FLYASH MAY BE USED AS A PARTIAL <br />SUBSTITUTE FOR CEMENT PROVIDED FLY ASH CONFORMS TO ASTM C618 FOR <br />CLASS N AND F MATERIALS AND FLY ASH CONTENT DOES NOT EXCEED 15% BY <br />WEIGHT OF ALL CEMENTITIOUS MATERIALS. <br />C. AGGREGATE SHALL CONFORM TO ASTM C33. <br />D. CONTRACTOR SHALL RETAIN A TESTING LABORATORY TO DESIGN AND TEST <br />CONCRETE MIX DESIGNS. MIX DESIGNS MAY BE PROPORTIONED BASED ON FIELD <br />EXPERIENCE IN ACCORDANCE WITH ACI 301-10, SECTION 4.2.3.1. FIELD STRENGTH <br />DATA SHALL BE SUBMITTED IN ACCORDANCE WITH ACI 318-14, SECTION 26.4.4 AND <br />SHALL BE CURRENT WITHIN THE LAST 12 MONTHS AND NOT SPANNING LESS THAN <br />60 CALENDAR DAYS, AND SHALL BE BATCHED FROM THE SAME PLANT USING <br />MATERIALS FROM THE SAME SOURCES. FOR CONCRETE TO BE PLACED BY PUMP: <br />1) SUBMIT SEPARATE MIX DESIGNS FORMULATED FOR PLACEMENT BY PUMP. <br />2) SLUMP CONTROL SHALL BE AT THE PUMP HOPPER AND NOT AT THE END OF <br />THE LINE. <br />3) SUBMIT WRITTEN VERIFICATION FROM THE CONCRETE PLACEMENT <br />SUBCONTRACTOR AS TO THE PUMPABILITY OF THE PROPOSED MIXES. <br />E. ALL CONCRETE SHALL BE READY-MIXED CONCRETE AND SHALL BE BATCHED, <br />MIXED AND DELIVERED TO SITE PER ASTM C94. WATER SHALL BE ADDED ONLY TO <br />OBTAIN MINIMUM SLUMP EXCEPT THE QUANTITY OF THE BATCHED WATER PLUS THE <br />WATER ADDED AT THE SITE SHALL NOT EXCEED THE QUANTITY OF WATER AS <br />STATED ON THE MIX DESIGN. PLACE CONCRETE WITHIN 90 MINUTES OF THE <br />ADDITION OF MIXING WATER. <br />F. REINFORCEMENT SHALL BE ASTM A615, GRADE 6O. <br />G. REINFORCEMENT SHALL BE FABRICATED WITH BEND AND HOOKS CONFORMING <br />TO ACI 315 AND AS SHOWN ON DRAWINGS. LAP ALL REINFORCING MINIMUM OF 40 <br />BAR DIAMETERS (BUT NOT LESS THAN 12") UNLESS OTHERWISE NOTED. <br />H. REINFORCEMENT SHALL BE HELD SECURELY IN PLACE AND SUPPORTED ON <br />GALVANIZED CHAIRS CONFORMING TO CRSI. WIRE TIE ALL INTERSECTIONS. <br />CONCRETE DOBIES MAY BE USED TO SUPPORT REBAR CAST AGAINST EARTH. <br />I. MINIMUM CONCRETE COVER OVER REINFORCEMENT SHALL BE: 3" FOR <br />CONCRETE CAST AGAINST EARTH, 2" FOR FORMED SURFACES EXPOSED TO <br />EARTH OR WEATHER, AND 1" FOR FORMED SURFACES NOT EXPOSED TO WEATHER <br />UNLESS OTHERWISE SHOWN. <br />J. ALL CONCRETE SHALL BE VIBRATED. <br />K. PROVIDE SLAB ON GRADE JOINTS PER DETAILS. <br />L. CHAMFER OR TOOL ALL EXPOSED EDGES 3/4". <br />M. PROVIDE HOT AND COLD WEATHER PROTECTION PER ACI 305 AND 306 <br />RESPECTIVELY. <br />N. ALL CONCRETE SHALL BE CURED FOR 7 DAYS MINIMUM BY WET CURING, OR WITH <br />CURING COMPOUND. CURING COMPOUNDS TO BE COMPATIBLE WITH FLOOR <br />FINISHES. <br />O. AFTER SLAB IS PLACED SEAL WATER TIGHT SLAB BLOCKOUTS AND SLAB EDGES <br />WHERE THE VAPOR BARRIER IS EXPOSED SO THAT WATER/MOISTURE FROM ALL <br />SOURCES (CURE WATER, RAIN WATER, ETC) IS NOT ALLOWED TO PENETRATE <br />BETWEEN THE SLAB AND VAPOR BARRIER. <br />4. STRUCTURAL STEEL <br />A. ALL STEEL CONSTRUCTION SHALL BE DETAILED, FABRICATED, AND ERECTED IN <br />ACCORDANCE WITH THE AISC 360-10 "SPECIFICATIONS FOR STRUCTURAL STEEL <br />FOR BUILDINGS", AISC 303-10 "CODE OF STANDARD PRACTICE FOR STEEL <br />BUILDINGS AND BRIDGES", AND AISC 341-10 “SEISMIC PROVISIONS FOR <br />STRUCTURAL STEEL BUILDINGS". <br />B. PLATES - ASTM A36; PIPE - ASTM A53, GRADE B; MACHINE BOLTS - ASTM A307; <br />HIGH STRENGTH BOLTS TO BE ASTM A325; ANCHOR BOLTS SHALL BE HEADED <br />OR THREADED ANCHORS PER ASTM F1554, GRADE 36 UNLESS OTHERWISE <br />NOTED ON DRAWINGS WITH STANDARD NUTS. <br />C. WELDING: <br />1) SHALL CONFORM TO AWS D1.1. ALL WELDING SHALL BE DONE BY QUALIFIED <br />WELDERS FOR MATERIALS TO BE WELDED. <br />2) ELECTRODES - FILLER METALS SHALL CONFORM TO THE REQUIREMENTS OF <br />THE LATEST EDITION OF ANSI/AWS SPECIFICATIONS FOR ELECTRODES. <br />MINIMUM TENSILE STRENGTH OF WELD METAL SHALL BE 70 KSI TYPICAL <br />UNLESS OTHERWISE NOTED. <br />3) FILLET WELDS - FILLET WELD SIZES SHALL BE THE LARGER OF THE SIZES AS <br />SHOWN ON STRUCTURAL DRAWINGS AND AS REQUIRED BY ASIC TABLE J2.4. <br />D. SUBMITTAL DRAWINGS: <br />1) OBTAIN ENGINEER'S REVIEW OF SUBMITTALS IN A TIMELY MANNER SO AS <br />NOT ADVERSELY AFFECT CONSTRUCTION SCHEDULE. ALLOW 10 WORKING <br />DAYS FOR REVIEW. <br />2) SUBMITTAL DRAWINGS: <br />A)SHALL INDICATE PROFILES, SIZES, SPACING, LOCATIONS OF STRUCTURAL <br />MEMBERS, OPENINGS, ATTACHMENTS, AND FASTENERS. <br />B)SUBMIT SHOP STANDARDS FOR EACH TYPE OF CONNECTION REQUIRED, <br />CORRESPONDING TO STRUCTURAL DRAWINGS. <br />C)SUBMIT ERECTION AND PLACING DRAWINGS SHOWING SIZE AND PIECE MARK <br />OF EACH MEMBER AND ITS LOCATION. <br />D) SHALL INDICATE WELDED CONNECTIONS WITH AWS A2.4 WELDING <br />SYMBOLS. INDICATE NET WELD LENGTHS. <br />E) SUBMIT SUBMITTAL DRAWINGS ELECTRONICALLY. REVIEWED SUBMITTAL <br />DRAWINGS WILL BE RETURNED ELECTRONICALLY TO THE CONTRACTOR <br />FOR REPRODUCTION AND DISTRIBUTION. <br />E. PRIME PAINTING OF STEEL NOT REQUIRED EXPECT WHERE STEEL IS EXPOSED TO <br />VIEW. <br />5. WOOD <br />A. ALL FRAMING MEMBERS SHALL BE IDENTIFIED BY GRADE STAMP OF PACIFIC <br />LUMBER INSPECTION BUREAU, INC (PLIB). <br />B. FRAMING MEMBERS TO BE AS FOLLOWS: <br />1) 4X AND SMALLER MEMBERS - DF NO 2 WITH 19% MAXIMUM MOISTURE <br />CONTENT. <br />2) 6X AND LARGER MEMBERS - D.F. NO. 1 WITH 19% MAXIMUM MOISTURE <br />CONTENT. <br />3) PLATES LEDGERS, AND BLOCKING - D.F. NO. 2 WITH 19% MAXIMUM MOISTURE <br />CONTENT. <br />C. PRESERVATIVE TREATED WOOD: <br />1) PRESERVATIVE TREATED WOOD SHALL BE USED ONLY WHERE SHOWN ON <br />DRAWINGS AND SHALL NOT BE USED IN PLACE OF OTHER FRAMING UNLESS <br />WRITTEN AUTHORIZATION FROM THE STRUCTURAL ENGINEER IS OBTAINED. <br />2) PRESERVATIVE TREATMENT SHALL BE EITHER ZINC BORATE OR DOT <br />SODIUM BORATE. <br />3) NAILS USED TO FASTEN FRAMING AND CONNECTORS TO PRESERVATIVE <br />TREATED WOOD SHALL BE HOT DIPPED GALVANIZED IN ACCORDANCE WITH <br />ASTM A653, CLASS G90. NO SUBSTITUTIONS ALLOWED WITHOUT WRITTEN <br />AUTHORIZATION FROM THE STRUCTURAL ENGINEER. <br />D. JOIST HANGERS AND FRAMING CONNECTORS - STANDARD ITEMS AS <br />MANUFACTURED BY SIMPSON STRONG-TIE CO. (OR EQUAL), INSTALLED FOR FULL <br />RATED LOAD VALUES. <br />E. MACHINE BOLTS - ASTM A307. PROVIDE WASHERS UNDER BOLT HEADS WHICH <br />BEAR AGAINST WOOD. <br />F. ALL FRAMING MEMBERS ARE TO BE CUT FOR FULL BEARING AND PROPER <br />LENGTH. <br />G. NAILING - PER CBC TABLE 2304.9.1. ALL NAILS TO COMMON UNLESS NOTED <br />OTHERWISE ON THESE DRAWINGS. NAILING FOR JOIST HANGERS AND FRAMING <br />CONNECTORS PER MANUFACTURER'S REQUIREMENTS FOR FULL RATED VALUES <br />OR AS NOTED. <br />H. LAG BOLTS: <br />1) LAG BOLTS SHALL CONFORM TO ANSI/ASME STANDARD B18.2.1. <br />2) LEAD HOLES FOR LAG BOLT INSTALLATION: <br />A)CLEARANCE HOLE FOR THE SHANK SHALL HAVE THE SAME DIAMETER AS <br />THE SHANK DIAMETER, AND THE SAME DEPTH OF PENETRATION AS THE <br />LENGTH OF THE UNTHREADED SHANK. <br />B)LEAD HOLE FOR THE THREADED PORTION SHALL HAVE A DIAMETER EQUAL <br />TO 60% TO 75% OF THE SHANK DIAMETER AND A LENGTH EQUAL TO AT <br />LEAST THE LENGTH OF THE THREADED PORTION. <br />3) THE THREADED PORTION OF THE LAG BOLT SHALL BE INSERTED IN ITS LEAD <br />HOLE BY TURNING WITH A WRENCH, NOT BY DRIVING WITH HAMMER. <br />4) SOAP OF OTHER LUBRICANT SHALL BE USED ON THE LAG BOLTS OF IN THE <br />LEAD HOLES TO FACILITATE INSERTION AND PREVENT DAMAGE TO THE LAG <br />SCREW. <br />I. PLYWOOD: <br />1) ROOF SHEATHING SHALL BE 15/32" MIN APA RATED SHEATHING, 32/16 <br />PANEL INDEX, EXPOSURE 1. INSTALL SHEETS WITH SHEET LONG DIMENSION <br />PERPENDICULAR TO SUPPORTS. BLOCKING REQUIRED AS NOTED ON THESE <br />DRAWINGS. <br />2) SHEAR WALL SHEATHING SHALL BE 15/32" MINIMUM APA RATED SHEATHING, <br />MINIMUM 24/0 PANEL INDEX, EXPOSURE 1. <br />J. SHOP FABRICATED STRUCTURAL WOOD: <br />1) LAMINATED STRAND LUMBER (LSL) SHALL BE LP SOLIDSTART AS <br />MANUFACTURED BY LOUISIANA PACIFIC CORP IN ACCORDANCE WITH ICC <br />ESR-2403 OR APPROVED EQUAL. <br />2) LAMINATED VENEER LUMBER (LVL) SHALL BE REDLAM LVL’S AS <br />MANUFACTURED BY REDBUILT, LLC IN ACCORDANCE WITH ICC ESR-2993 OR <br />APPROVED EQUAL. <br />K. METAL PLATE WOOD TRUSSES: <br />1) DESIGNED AND MANUFACTURED IN ACCORDANCE WITH TPI'S DESIGN <br />RECOMMENDATIONS. <br />2) TRUSS MANUFACTURER SHALL DESIGN MEMBERS FOR LOADING CRITERIA <br />AS INDICATED ON DRAWINGS AND MEMBER PROFILES SHALL CONFORM TO <br />INDICATED GEOMETRY. <br />3) EACH TRUSS TO BE TAGGED IDENTIFYING TRUSS MANUFACTURER, DESIGN <br />LOAD, AND SPACING. THIS INFORMATION SHALL BE LEGIBLE AND <br />PERMANENTLY AFFIXED ON THE BOTTOM CHORD OF THE TRUSS WITHIN THE <br />2'-0" OF TRUSS CENTERLINE. <br />4) TRUSS MANUFACTURER SHALL SUBMIT ELECTRONICALLY TRUSS <br />ENGINEERING SEALED BY A CA REGISTERED CIVIL OR STRUCTURAL ENGINEER. <br />REVIEWED TRUSS ENGINEERING WILL BE RETURNED ELECTRONICALLY TO THE <br />CONTRACTOR FOR REPRODUCTION AND DISTRIBUTION. TRUSS ENGINEERING <br />TO INCLUDE: <br />A)TRUSS LAYOUTS. <br />B)CALCULATION AND DETAILS FOR EACH TRUSS SHOWING THAT THE DESIGN <br />(AXIAL AND BENDING STRESSES, TRUSS REACTIONS, AND JOINT DESIGNS) <br />ARE IN CONFORMANCE WITH 2001 CBC AND LOADING CRITERIA NOTED ON <br />DRAWINGS. <br />C)MANUFACTURER TO OBTAIN’S ENGINEER OF RECORD’S APPROVAL (IN THE <br />FORM OF SHOP DRAWING APPROVAL STAMP OR SEPARATE APPROVAL <br />LETTER) FOR SUBMITTAL TO BUILDING DEPARTMENT MINIMUM OF 2 WEEKS <br />PRIOR TO TRUSS INSTALLATION. <br />5) TRUSS MANUFACTURER RESPONSIBLE FOR SPECIFYING TEMPORARY, <br />ERECTION, AND PERMANENT BRACING. <br />6. INSPECTIONS <br />A. EARTHWORK: <br />1) PRIOR TO THE CITY’S FOUNDATION INSPECTION, PROVIDE THE BUILDING <br />DEPARTMENT WITH COPIES OF COMPACTION/SOIL ANALYSIS REPORTS. <br />2) PRIOR TO REQUESTING BUILDING INSPECTION OF BUILDING PADS AND <br />FOUNDATIONS, OBTAIN AND SUBMIT TO BUILDING DEPARTMENT <br />GEOTECHNICAL ENGINEER’S WRITTEN APPROVAL OF THE BUILDING PADS AND <br />FOUNDATION BEARING SURFACES. <br />B. CONCRETE <br />1) FOOTINGS AND INTERIOR SLABS ON GRADE TO HAVE SPECIAL <br />INSPECTIONS IN ACCORDANCE WITH CBC TABLE 1705.3. <br />2) EXTERIOR SLABS, SIDEWALKS, AND CURBS & GUTTERS - SPECIAL <br />INSPECTION NOT REQUIRED. EXCEPTIONS 1, 2.3, AND 3 OF CBC 1704.4 <br />APPLIES.. <br />3) ANCHOR BOLTS FOR PRE-ENGINEERED METAL SHALL HAVE SPECIAL <br />INSPECTION IN ACCORDANCE WITH CBC 1704.5.3. <br />C. WOOD SHALL HAVE SPECIAL INSPECTION IN ACCORDANCE WITH AND IF <br />REQUIRED BY CBC SECTIONS 1705.11 AND 1705.12. <br />D. STEEL: <br />1) WELDING SHALL HAVE SPECIAL INSPECTION IN ACCORDANCE WITH CBC <br />1705.2.1 AND ASIC 360. WELDING IN AN APPROVED FABRICATOR'S SHOP IN <br />ACCORDANCE WITH CBC 1705.2 MAY NOT REQUIRE CONTINUOS SPECIAL <br />INSPECTION. PERIODIC INSPECTIONS SHALL BE IN ACCORDANCE WITH AISC <br />360. <br />2) HIGH STRENGTH BOLTING <br />A)SHALL HAVE SPECIAL INSPECTION IN ACCORDANCE WITH AISC 360. <br />B)HIGH STRENGTH BOLTS TO HAVE SPECIAL INSPECTION IN ACCORDANCE <br />WITH METAL BUILDING DRAWINGS. <br />BOTT <br />OF CONT FTG <br />NOTE: <br />CONCRETE FILL @ PIPE SHALL BE SAME WIDTH AS CONT FTG, FULL <br />WIDTH OF TRENCH, & SHALL BE PLACED BEFORE CONT FTG IS POURED <br />NO FORMS <br />UNREINFORCED <br />CONC FILL <br />BOTT <br />OF CONT FTG <br />TYP REINF <br />WHERE BOTT REINF IS <br />INTERRUPTED ADD <br />SAME SIZE BAR x <br />10'-0" MIN CENTERED <br />ON SLEEVE. TYP REINF <br />TO RUN THRU WHERE <br />POSSIBLE <br />PROVIDE 40 BAR <br />DIAMETER LAPS <br />TYP <br />BELOW CONT FTG:PIPE SLEEVE IS 4" BELOW BOTT OF CONT FTG. <br />CONCRETE ENCASEMENT NOT REQ WHEN TOP OF <br />PIPE IS 12" MIN BELOW BOTT OFCONT FTG. <br />THRU CONT FTG CASE:PIPE SLEEVE IS BETW 6" MAX CLR ABV BOTT <br />OF FTG & LESS THAN 4" BELOW BOTT OF FTG <br />TRENCH TYP <br />6" MIN <br />8" <br />MIN <br />2' - 0" MIN <br />NOTE: <br />PIPES MAY PENETRATE THRU CONT FOOTING, <br />NOT THRU SPREAD FOOTINGS <br />PROVIDE SLEEVE <br />1" CLR AROUND <br />PIPE -TYP <br />BOTT <br />OF CONT FTG TRENCH OR EXCAVATION1.5 <br />1 <br />BOTTOM OF <br />EXCAVATION. PIPE <br />SHALL NOT EXTEND <br />BELOW THIS LINE <br />THRU CONT FTG CASE:PIPE SLEEVE IS 6" CLR ABV BOTT OF CONT FTG. <br />PIPE SLEEVE IS TO BE 6" MIN CLR OF TOP OF FTG.PER PLAN6" MINTHAN 18" <br />NOT LESS <br />SLEEVE DIAMETERGREATER OF6" MIN OR1 <br />2 MIN1 <br />2 MIN <br />MIN6"4"MINBAR BEND DIAMETER: D = 6d FOR #8 & SMALLER <br />D = 8d FOR #9, #10, & 11 <br />D=10d FOR #14 & #18 <br />12 <br />2 <br />180° HOOK 90° HOOK <br />135° MIN <br />D6d AND 3"GREATER OFd <br />90° <br />d D12d FOR #6, #7, #8. <br />GREATER OF <br />4d AND 2å" <br />GENERAL NOTES <br />COVER PER <br />STIRRUP/TIE HOOKS <br />GREATER OF 6d <br />AND 3" FOR #3, <br />#4, & #5 <br />BAR BEND DIAMETER: D = 4d FOR #3, #4, & #5 <br /> D = 6d FOR #6, #7, & #8 <br />dUON12dTYPD <br />SC-1 PER PLAN <br />SUBBASE PREPARATION <br />SEE PLAN <br />REINFORCING <br />PER PLAN <br />SLAB PER <br />PLAN <br />å" x 2'-0" SMOOTH <br />GREASED DOWEL <br />w/ SAWCUT ENDS @ <br />MID-DEPTH @ 24" OC <br />#4 CONT EA SIDE <br />OF JT <br />DRAINAGE BASE <br />TOOL w/ á" RADIUS <br />EA SIDE <br />TOOLED JT OPTION <br />SOFF-CUT OPTION <br />2"2" <br />EQ EQ <br />VAPOR BARRIER <br />MIN DEPTH SOFF- <br />CUT: <br />1ß" @ 4" SLAB <br />1á" @ 5" SLAB <br />NOTE: <br />SEE UONS001 <br />16 <br />SC-2 PER PLANREINF CONT <br />THRU SC <br />CJ-1 PER PLAN <br />FULL DEPTH <br />TOOL w/ á" RADIUS <br />EA SIDE <br />NOTE: <br />SEE UON16 <br />S001 <br />CORNER INTERSECTION END <br />FTGS w/ (2) BARS IN HORIZONTAL PLANE SHOWN, <br />CONDITIONS w/ ADDITIONAL BARS SIMILAR. <br />CORNER INTERSECTION <br />1'-0" BEND <br />TYP <br />SINGLE/STACKED BAR FTG <br />FTG BARS SIDE BY SIDE <br />12" HK <br />TYP. UON <br />TYP <br />3" CLR <br />PLANSEE0" TYP0" TYPSTANDARD <br />HKPER PLAN.TYPPER PLAN.TYPANCHOR/DOWEL <br />PER DETAILS <br />ADHESIVE FILLED <br />DRILLED HOLE <br />PER SCHED <br />EMBED DEPTHPER SCHEDDRILL BIT øHDR ATTACHMENT <br />SAME AS WINDOW <br />FULL HT KING (K) <br />TYP-UON <br />2x @ 16" OC <br />2x JACK STUD (JS) <br />TYP. UON <br />HEADER <br />PER PLAN <br />LAMINATE STUDS <br />w/ 16d SINKERS <br />@ 12" OC UON <br />(2) 16d SINKER END NAILS EA ROW. <br /># OF ROWS = NOMINAL BM DPTH/2 <br />BUT NOT TO EXCEED 4 ROWS. <br />PROVIDE TOE NAILS @ 4x & 6x (K) <br />2x BLKG (4) LOC <br />FIN FLR <br />HEAD <br />PER ARCH <br />SILL <br />PER ARCH <br />A35 (A24 @ 2x4 WALL) T& B <br />EA END FOR HDR SPAN > <br />8'-0" <br />WINDOW <br />FULL HT <br />KING (K) <br />TYP-UON <br />2x @ 16" OC <br />2x JACK STUD (JS) <br />TYP-UON <br />HEADER <br />PER PLAN <br />LAMINATE STUDS <br />w/ 16d SINKERS <br />@ 12" OC UON <br />2x BLKG <br />(2) LOC <br />FIN FLR <br />HEAD <br />PER ARCH <br />DOOR <br />DBL SILL ð FOR <br />OPNG > 12'-0" UON <br />(2) 16d SINKER END <br />NAILS T& B OF (K). TYPNOTES: <br />1. SEE FOR BORED HOLES & NOTCHES IN STUDS. <br />2. SEE FOR BUILDING UTILITIES AT WALL TOP PLATES. <br />24 <br />S001 <br />23 <br />S001 <br />3.NAILING TO BE PER CBC TABLE <br />2304.10-1 UON. <br />4.WALL & OPGN LAYOUT DIMS TO BE <br />PER ARCH. <br />2X SILL ð w/ (2) <br />16d SINKER END <br />NAILS EA END. TYP <br />DBL TOP ƒ <br />WALL STUDS <br />@ 16" OC <br />(16) 16d SINKERS <br />STAGGERED <br />NOTE: <br />WHERE 4'-0" SPLICE IS NOT AVAILABLE PROVIDE CS16x24" w/ <br />8d EVERY OTHER HOLE EA SIDE <br />DBL TOP ð SPLICE, TYP UON <br />STUD w/ NOTCH <br />Dn 4DnMAXDEPTH <br />STUD <br />DO NOT OVERCUT <br />NOTCH @ CORNERS <br />STUD w/ BORED HOLE <br />DEPTH <br />STUD <br />D h ø <br />ç" <br />MIN <br />ç" <br />MIN" <br />NOTES: <br />1.STRUCTURAL WALLS - WALL FRAMING AS SHOWN ON STRUCTURAL DWGS. <br />2.NON-STRUCTURAL WALLS - WALL FRAMING NOT SHOWN ON STRUCTURAL DWGS UON. <br />3. BORED HOLES AND NOTCHES SHALL NOT BE LOCATED AT SAME SECTION. <br />4.6x POSTS SHALL NOT BE BORED OF NOTCHED. <br />5.4x STUDS SHALL NOT BE NOTCHED BUT MAY HAVE BORED HOLES SAME AS FOR <br />STRUCTURAL WALLS PROVIDED THE BORED HOLES ARE CENTERED ON THE 4X DEPTH. <br />6.MAX O F 1 NOTCH PER STUD. <br />7. STUDS WITH MULTIPLE BORED HOLES ALLOWED PROVIDED ADJACENT BORED HOLES <br />ARE A MINIMUM OF 4 HOLE DIAMETERS CLEAR OF EACH OTHER USING THE LARGER <br />DIAMETER OF ADJACENT HOLES. <br />8.STUDS WITH 1 NOTCH AND MULTIPLE BORED HOLES ALLOWED PROVIDED ADJACENT <br />HOLES AND HOLES ADJACENT TO NOTCHES ARE CLEAR OF EACH OTHER SAME AS ITEM <br />7. <br />9. STUDS IN STRUCTURAL WALLS MAY HAVE BORED HOLE DIAMETER SAME AS <br />NON-STRUCTURAL WALLS PROVIDED STUD IS DOUBLED AND NOT MORE THEN 2 SUCH <br />SUCCESSIVE DOUBLED STUDS ARE SO BORED. <br />10.SILL PLATES ANCHORED TO CONCRETE - BORED HOLES AND NOTCHES TO BE <br />TREATED SAME AS END OF PLATE CONDITION - PROVIDE MIN 2 ANCHORS PER PIECE w/ <br />5" MAX/12" MIN CLEAR OF BORED HOLES OR NOTCHES. <br />11. DBL TOP PLATES AND BOTT PLATES AT WOOD FRAMED FLOORS ARE NOT TO BE <br />BORED OR NOTCHED UNLESS SPECIFICALLY DETAILED/NOTED ON DWGS. <br />WALL FRMG <br />PER PLAN <br />ð HT <br />PER PLAN <br />ALL UTLILITES (PIPES, CONDUITS, <br />SPRINKLER,COMMUNICATION, <br />LINES, ETC) TO BE ROUTED AS <br />REQ TO NOT PENETRATE DBL <br />TOP PLATE. <br />SEE FOR RESTRICTIONS IN RUNNING <br />UNTILITIES THRU WALL FRMG. <br />24 <br />S001 <br />PLYWD BLKG PANELS <br />SHEAR BLKG OPTION <br />EN TYP <br />16d SINKERS <br />@ 6" OC STGD <br />2x FILLER @ <br />TRUSS <br />16d SINKERS <br />@ 6" OC <br />ã" PLY OR OSB <br />w/ 8d @ 6" OC EN, <br />12" OC FIELD <br />DBL TOP ƒ <br />ð HT <br />PER PLAN <br />ð HT <br />PER PLAN <br />EN TYP <br />16d SINKERS @ 6" <br />OC <br />2x FILLER @ TRUSS <br />16d SINKERS TOE <br />NAIL @ 6" OC <br />LTP4 @ 24" OC <br />(MIN 1 PER BLK) <br />PROVIDE MFR TRUSS BLKG. HORIZ SHEAR = 260 plf <br />DBL TOP ƒ <br />NOTE: <br />1. VERIFY LOCATION w/ MECH. <br />4x6 BLKG w/ HUS46TF OR <br />HUSC46TF <br />@ EDGES OF MECH UNIT. USE <br />HUS46TF & HUSC46TF ON <br />OPPOSITES SIDES OF SAME RT <br />RT PER PLAN <br />1/2" MAX ANCHOR (AB) PER DETAILS <br />STANDARD CUT WASHER <br />ð WASHER PER <br />SCHD <br />WALL FRMG <br />PER PLAN <br />EN <br />PT ƒ SPLICE @ <br />MID-POINT OF OPNG <br />OR 6'-0" MIN FROM JAMBS <br />EN @ (K) STUDS <br />FULL HT <br />2x4 MIN BLK <br />32" MIN BEYOND <br />OPNG @ CS16 <br />STRAPPING <br />SIMPSON CS16 w/ <br />8d EVERY OTHER <br />HOLE -TOP & BOTT <br />PROVIDE (2) STRAPS <br />TOP & BOTT AS <br />NOTED ON PLANS <br />HEADER PER PLAN <br />32" MIN <br />PER PLAN <br />OPNG <br />WINDOW <br />DBL 2x OPTION TO 3x MIN @ ADJOINING EDGES <br />(2) VERT ROWS OF <br />STITCH NAILING <br />PER SCHD <br />ADJOINING PANEL EDGE <br />DBL 2x MATCH DEPTH <br />OF WALL FRMG1"1"2x CONT w/ (2) 16d <br />SINKERS @ EA BLK <br />FRAMING <br />PER PLAN <br />BLKG PER PLAN <br />w/ HANGER EA END <br />SHEAR PER PLANFRMG PER PLAN <br />FRAMING <br />PER PLAN <br />2x BLKG CONT. <br />MATCH FRMG <br />DEPTH <br />2x CONT w/ 16d <br />SINKERS @ 12" OC <br />MIN (2) PER BLK <br />EN <br />FRMG PARALLEL TO FRAMING <br />FRMG PERPENDICULAR TO FRAMING <br />16d SINKERS @ <br />12" OC. TYP <br />HEADER SIZE PER <br />PLAN EA FACE FULL <br />LENGTH, NO SPLICES <br />2x MATCH WALL FRMG <br />MATERIAL & WIDTH <br />TOC +0'-0" <br />+0' -0" <br />* <br />HOLDOWN PER PLAN w/ <br />SDS SCREWS PER SCHD <br />(2)2x OR POST PER <br />PLAN. LAMINATE 2x's <br />PER <br />SIMPSON HOLDOWN <br />ANCHOR ROD PER <br />SCHDa-aNOTE: <br />SEE UON EMBDMT12" MIN32 <br />S001 <br />5 <br />S201 <br />PLAN a-a <br />(2) ROWS EN @ <br />TWICE EN SPACING <br />Checked By: <br />Drawn By: <br />Project No.: <br />LDA Partners, LLP <br />222 South Central Court <br />Stockton, CA 95204 <br />209.943.0405 <br />www.ldapartners.com <br />Consultant: <br />Project: <br />Architect: <br />jh lawder, inc. <br />structural engineers <br />717 16th Street, Ste. 4, Modesto, CA 95354 <br />(209) 521-1143 Fax: (209) 521-1581 <br />Client: <br /> 5/06/21 <br />5/6/2021 9:34:09 AMGENERAL NOTES & TYPICAL <br />DETAILS <br />S001 <br />Author <br />JL <br />727-01-18 <br />PERMIT SUBMITTAL <br />5/5/21 <br />MACHADO SPORTS COMPLEX <br />450 COMMERCE COURT, MANTECA, CA <br />95336 <br />1020 MARSH CREEK <br />EBMA INVESTMENTS <br />###.###.#### <br />MANTECA, CA 95336 <br />1/2" = 1'-0"11 PIPES & EXCAVATIONS <br />3/4" = 1'-0"13 TYP REINF BAR BENDS <br />12" = 1'-0"14 ABBREVIATIONS <br />3/4" = 1'-0"16 SLAB ON GRADE JT: SC-1 <br />3/4" = 1'-0"17 SOFF-CUT JT: SC-2 <br />3/4" = 1'-0"18 SLAB ON GRADE JT: CJ-1 <br />1/2" = 1'-0"19 TYP FTG REINF -PLAN VIEW <br />20 ADHESIVE DOWELS/ANCHORS <br />1/2" = 1'-0"26 FRAMED OPENING <br />1" = 1'-0"22 TOP ƒ SPLICE <br />1" = 1'-0"24 BORED HOLES & NOTCHES <br />3/4" = 1'-0"23 BLDG UTILTIES @ DBL TOP ð <br />1/2" = 1'-0"25 BLKG PANELS <br />1/4" = 1'-0"33 HVAC UNIT SUPPORT <br />1 1/2" = 1'-0"31 WD ð -SLOTTED ð WASHER <br />1/4" = 1'-0"27 SPECIAL SHEAR WALL <br />3/4" = 1'-0"32 DLB 2x STITCH NAILING <br />1/2" = 1'-0"28 FRAMING DETAIL <br />ADHESIVE DOWELS <br />ANCHOR/ <br />DOWEL <br />DRILL <br />BIT ø <br />EMBED <br />DEPTH MATERIAL PROOF LOAD <br />#4 DOWEL ç"ø 4á" CONCRETE 2000# TENSION <br />BORED HOLES & NOTCHES - <br />NON-STRUCTURAL WALLS <br />STUD <br />BORED HOLE <br />MAX Dh <br />NOTCH DEPTH <br />MAX Dn <br />2x4 2"ø 1ã" <br />2x6 3á"ø 2ß" <br />2x8 4á"ø 2ë" <br />BORED HOLES & NOTCHES - STRUCTURAL <br />WALLS <br />STUD <br />BORED HOLE <br />MAX Dh <br />NOTCH DEPTH <br />MAX Dn <br />2x4 1ã"ø ë" <br />2x6 2ß"ø 1ã" <br />2x8 2ë"ø 1é" <br />BORED HOLES & NOTCHES - STRUCTURAL <br />WALLS <br />STUD <br />BORED HOLE <br />MAX Dh <br />NOTCH DEPTH <br />MAX Dn <br />2x4 1ã"ø ë" <br />2x6 2ß"ø 1ã" <br />2x8 2ë"ø 1é" <br />ADJOINING EDGE DBL 2x STITCH NAILING <br /> EN 16d SINKER SPACING <br />8d @ 6" OC 2 ROWS @ 12" OC EA ROW <br />8d @ 4" OC 2 ROWS @ 8" OC EA ROW <br />8d @ 3" OC 2 ROWS @ 6" OC EA ROW <br />8d @ 2" OC 2 ROWS @ 4" OC EA ROW <br />10d @ 6" OC 2 ROWS @ 11' OC EA ROW <br />10d @ 4" OC 2 ROWS @ 7" OC EA ROW <br />10d @ 3" OC 2 ROWS @ 5" OC EA ROW <br />10d @ 2" OC 2 ROWS @ 4" OC EA ROW <br />12" = 1'-0"6 GENERAL NOTES <br />3/4" = 1'-0"5 WOOD BU HEADER <br />3/4" = 1'-0"35 HOLDOWN DETAIL <br />No. Descripotion Date By <br />6/8/2021, 1:58:25 PM <br />21-0396 <br />LUMEN ARCEO