Laserfiche WebLink
OPW 6150 OVERFILL PREVENTION VALVES <br />OPW 61S0-1000 and <br />61S0-100C Grooved Tube <br />The OPW 61S0-1000 and <br />61S0-100C Overfill Prevention <br />Valves feature a grooved tube design <br />eor use in two-point applications with <br />gauging probes. The 61S0-100C <br />is CARB approved. <br />These valves have a slotted section <br />that runs through both the tube and the <br />valve body to allow the installation of <br />most manufacturer's gauging systems - <br />with only a negligible effect on product <br />delivery time. <br />Assembly <br />All OPW 6 !SO series valves are <br />furnished with complete instructions <br />and all of the necessary hardware for <br />field or shop assembly. <br />For complete assembly and <br />installation instructions, refer to: <br />H-11764M: 61S0 and 61SOM <br />H-13791M: 61S0 and 61SOM-CARB <br />C-3634PA: 61SOC <br />H-13792M: 61S0P <br />H-11964M: 61SOR <br />H-11764M: 61S0 (3") <br />C-4081M: 61S0-1000 (Grooved) <br />Materials <br />Valve body: cast aluminum <br />Float nitrile rubber, dosed cell foam <br />Valve: aluminum <br />Seals: viton <br />Upper & lower Drop Tube: aluminum <br />Plastic parts: Acetal <br />Hardware: Stainless Steel <br />Replacement Parts <br />Part No. Description <br />O000l Aoat <br />C03899M :Ivo point inlet tube <br />C03632M Coaxial inlet tube <br />NY city Fire <br />CARB Department <br />Important <br />In order to prevent product spillage <br />from the Underground Storage Tank <br />(UST), properly maintained delivery <br />equipment and a proper connection at <br />the tight fill adaptor are essential_ <br />Delivery personnel should be managed <br />and trained to inspect delivery elbows <br />and hoses for damaged and missing <br />parts. They should always make certain <br />there is a positive connection between <br />the adaptor and elbow. If delivery <br />equipment is not properly maintained, <br />or the elbow is not securely coupled to <br />the adaptor, a serious spill may result <br />when the OPW 61S0 closes, causing <br />a hazard, and environmental contamina- <br />tion. <br />Note: The OPW 6130 Overfill <br />Prevention Valve is not to be used in <br />pumping applications. The 61S0 is <br />designed only for tight fill, gravity <br />drop applications. <br />Information <br />For additional useful information on <br />the specification, assembly, installation <br />and use of the OPW 61S0, refer to <br />Technical Bulletin TB-61S0. <br />OPW 61S0 Overfill Prevention <br />Valves are covered under the following <br />patent: 4,986,320. Re 33,555 and <br />Canadian patent 1,287,546. Other <br />patents pending. <br />Certifications <br />and Listings <br />i1SO Series Initial Approval <br />Certification #4902 <br />Letter Oct 88 <br />Updated Approval <br />Letter #97-04 <br />l.etter #90-S <br />ifcar <br />61SOP Approval <br />Latter #92-8 <br />IMPORTANT: OPw pteducts should be used in <br />compliance with applicable federal. state and local laws <br />and regulations. Product selection should be based on <br />physical spa:A:anon and limitations and compatibility <br />with the environment and materials to be handled. <br />OPW MARES NO WARRANTY OF FTTNESS <br />FORA PARTICULAR USE. All Monti= and <br />specifications in this lin:mune VIZ based on the haat <br />mina intimation available at the time of publication. <br />OPW reserves the tight to make changes at any time in <br />prices, materials. specifications and models and to <br />iliscotoinue mcdels without notice or obligation. <br />SO/170 <br /> <br />6E:TI 000E-6T—nON