Laserfiche WebLink
Flexible • • • • • • Manual environ <br /> 13.1 Coax Couplings & Fittings <br /> Coax couplings&fittings are a double wall design and are used to interconnect GeoFlex®-D,GeoFlex®-S and GeoVent-piping.These UL®listed <br /> composite couplings and fittings may be direct buried and are not necessarily required to be contained within containment sumps. Used with <br /> GeoFlex-D double wall piping,coax couplings and fittings permit the entire flexible piping system, including riser pipes and shear valves,to be <br /> secondarily contained,tested and monitored. The coax couplings&fittings are illustrated below. <br /> Air <br /> Shear Valves\ Shear Valves\ <br /> Fitting\ 1 <br /> Coax <br /> Shear Valve <br /> Steel Riser - Adapter <br /> Pipes Riser Coax Riser <br /> Jacket /Pipe Adapter <br /> Test Tube <br /> Coax Riser <br /> Riser Pipe Jacket <br /> Coax <br /> � Coax Pipe Adapter Shear Valve <br /> 1' Connector Adapter Kit Coax <br /> J Coax Male Riser <br /> Adapter Kit <br /> Coax Pipe Coax Tee <br /> Coupling Fittings <br /> Coax <br /> Elbow <br /> GeoFlex Piping Fitting <br /> 3.1.1 Coax Pipe Couplings 3.1.5 Coax Elbow Fitting <br /> These couplings provide a means of connection These elbow fittings may be used in two different <br /> from GeoFlex®piping to coax fittings and adapters. applications. The first application is to connect a <br /> Coaxial pipe couplings attach to a flexible pipe section of GeoFlex piping fitted with a coax <br /> section using the GeoF/ex Coupling Machine.Each coupling to a steel riser pipe.This application is 110 <br /> coupling assembly includes a stainless steel insert used to terminate a piping run with a standard <br /> threaded riser pipe.Connection to a threaded riser <br /> with two 0-rings, ferrule with one 0-ring, and a pipe requires the use of a coax riser adapter or riser jacket kit described <br /> swivel nut.Available for both single wall and double wall applications. later in this publication.The second application for coax elbow fittings is <br /> NOTE: Coax couplings require a different coupling machine to connect two sections of GeoFlex piping fitted with coax couplings. <br /> face plate than is used with the swivel couplings. <br /> This is useful when a sharp 90'degree turn is required. <br /> 3.1.2 Coax Pipe Adapters 3.1.6 Coax Riser Pipe Adapter <br /> These stainless steel adapters contain a female <br /> These adapters are designed to connect one end pipe thread on one side and a custom coaxial �. <br /> of a flexible pipe section fitted with a coax pipe <br /> coupling to a 2"NPT threaded female coupling or male face to accept coax fitting at the opposite R- <br /> end.These adapters are used with coax tee fittings <br /> fitting.The adapter has a 1/4" threaded and <br /> plugged test port for future installation of coax and coax elbow fittings where interfacing with a <br /> test tube for testing the interstitial space of the standard threaded riser pipe is required. <br /> GeoFlex-D piping. <br /> 3.1.7 Coax Riser Kit <br /> 3.1.3 Coax Connector Coupling The coax riser kit is used when isolation of a partial <br /> length of the riser pipe is required.The kit consists <br /> These connectors are designed to connect two of a coax riser pipe adapter,coax riser adapter,two <br /> flexible pipe sections fitted with coax pipe riser pipe nuts, coax riser plug w/0-rings, seals <br /> couplings. This is ideal when using extra-long and a 36"length of coax riserjacket.The coax riser <br /> piping runs and when connecting short lengths of jacket is a UL listed, nonmetallic stand-off jacket <br /> flexible piping together. They can be direct buried, that provides isolation from the environment as <br /> so containment sumps are not required. well as interstitial space for monitoring. <br /> 3.1.4 Coax Tee Fitting 3.1.8 Coax Shear Valve Kit <br /> These tee fittings may be used in two different The coax shear valve kit is used when the isolation <br /> applications.The first application is to connect two of the full length riser pipe is required in a direct <br /> sections of Geoflex piping fitted with coax burial application.The kit consists of a coax riser <br /> couplings to a steel riser pipe.This application is adapter,coax shear valve adapter,two riser pipe <br /> fused in any configuration where connection of a <br /> ;ee to a standard threaded riser pipe is needed. nuts,one extra long riser adapter nut,coax riser <br /> plug w/0-rings, seals and a 36" length of coax <br /> Connection to a threaded riser pipe requires the riser jacket. The coax riser jacket is a UL listed, <br /> use of a coax riser adapter or riser jacket kit described later in this nonmetallic stand-off jacket that provides isolation from ground <br /> publication. The second application for coax tee fittings is to connect environment as well as interstitial space for monitoring. 2" NPT base- <br /> three sections of GeoFlex piping fitted with coax couplings. threaded shear valves are required for the coax shear valve kit. <br /> 3 <br />