Laserfiche WebLink
modern Mode, ii Welding Company, Inc <br /> PO Box 1450 - Owensboro, KY - 42302 <br /> Subsidiaries Nationwide - (502)685-4400 <br /> Installation Instructions - Glasteel II Jacketed Steel Tanks <br /> INTRODUCTION Using compatible, non-hardening pipe sealant, <br /> 1.0 Proper installation is essential to the expected product life install permanent metal plugs in all unused <br /> and performance on Moderns' Glasteel II Underground openings. <br /> Storage Tank. This tank must be installed in accordance 4.2 Refer to Modern Welding Company's publication, <br /> with these installation instructions,the latest issue of "Finishing Instructions"for proper installation of <br /> N.F.P.A. 30 and 31 pamphlet,the PEURP-100 and local permanent coverings for unused openings and <br /> authorities having jurisdiction over underground tank lifting lugs. <br /> installations and codes. 4.3 For Glasteel 11 tanks fabricated without <br /> 1.1 Although the instructions are clear and precise, dielectric isolation, (threaded nylon bushings or <br /> unexpected conditions often occur and thus flange isolation kits)this tank must use either: <br /> prudent thought,coupled with extreme care A)Non-metallic piping,or <br /> become the proper procedure. B)Conductive piping must be isolated from <br /> the backfill material and any other metal <br /> TANK HANDLING or grounding device. <br /> 2.0 Extreme caution shall be used when handling the <br /> tank. Do not drop or roll the tank. TESTING <br /> 2.1 Equipment to lift and lower the tank shall be of 5.0 Glasteel 11 tanks are shipped with a vacuum on <br /> sufficient capacity to do so without dragging or the annular space. If a minimum of 5.3 inches <br /> dropping the tank. Hg of vacuum is maintained for one hour,both the <br /> 2.2 The tank shall be lifted and lowered using the inner tanks and outer tank may be considered <br /> lifting lugs or lifting plugs provided. Cables or properly tested.Fluctuations in interstice vacuum <br /> chains used shall be of adequate length. No are caused by temperature and barometric <br /> circumstances warrant the use of chains or slings pressure changes. <br /> around the tank shell. Maximum angle of the NOTE:NFPA 30: 2-8.3:1 Secondary containment <br /> sling shall be 60 degrees. tanks shall have the interstitial(annulus)space <br /> tested using vacuum at 5.3 in-Hg. The vacuum <br /> TANK STORAGE shall be held for one hour. Care shall be taken <br /> 3.0 If tank is stored on site prior to installation, a to ensure that the interstitial space is not <br /> secure area shall be chosen. Special attention subjected to excessive vacuum. <br /> shall be placed in selecting the storage location to NFPA 30: 2-8.4: "Before the tank is initially <br /> assure the absence of rocks and foreign objects placed in service,all leaks or deformations shall <br /> that might cause damage to the tank exterior. be corrected in an acceptable-manner." <br /> CAUTION: Do Not Pressure Test Interstitial <br /> (Annular) Space. <br /> EXCAVATION AND BEDDING <br /> 6.0 The excavation shall be properly accomplished <br /> and free from any material or object that would <br /> cause damage to the tank exterior. <br /> 6.1 The bottom of the excavation shall be suitably <br /> graded and leveled. The foundation for the tank <br /> shall be a minimum of 6 inches of clean,inert, <br /> compacted sand,6 inches of pea gravel,the <br /> largest particle of which does not exceed 3/4 inch, <br /> or rounded-cdge gravel crushings,angular <br /> INSPECTION particle size required to be not less than 1/8" <br /> 4.0 Visually inspect the tank exterior for damage. or more than 1/2". See chart in`Backfill Section" <br /> Any extreme gouging or abrasion should be carefully 6.2 There shall be a minimum of 12 inches from the <br /> reviewed and appropriate action taken. outside edge of the tank to the inside edge of the <br /> excavation. This distance shall remain true for the <br /> 4.1 Remove thread protectors and shipping plugs entire perimeter surrounding the tank. Multiple <br /> from all openings(except vacuum gage location). tank installation will also require a minimum of <br />