Laserfiche WebLink
Design Manual — Onsite Wastewater and Disposal Systems is required for each parcel . The fee <br /> will be based on the current schedule at the time of payment . <br /> b . The existing private water wells shall be tested for nitrates with the results submitted to the EHD <br /> prior to issuance of building permit ( s ) . Samples are to be taken and analyzed by a State - approved <br /> laboratory . ( San Joaquin County Development Title , Section 9 . 1115 . 7 ) . <br /> c . Prior to issuance of building permit , submit to the EHD revised site plans showing the location and <br /> configuration of any existing and proposed sewage disposal systems , along with the area required <br /> to be reserved for future sewage disposal repair/ replacement ( Area for 100 % sewage disposal <br /> replacement ) . The plans shall include the design calculations , including the maximum number of <br /> persons the sewage disposal system is proposed to serve . In addition , show on revised plans that <br /> the disposal field area will be barricaded so it cannot be driven over , parked on , or used as a <br /> storage area . This disposal field area must be used for that specific purpose only , and it cannot <br /> contain any underground utility lines ( San Joaquin County Development Title , Section 9 - <br /> 1110 . 4 [ c] [ 5 ] ) . <br /> d . An application for Waste Discharge Requirements must be submitted to the Central Valley regional <br /> Water Quality Control Board prior to development ( California Water Code , Article 4 , Section 13260 ) . <br /> e . Submit Water Provision Declaration form to the EHD for review . <br /> f. Any geotechnical drilling shall be conducted under permit and inspection by the EHD ( San Joaquin <br /> County Development Title , Section 9 - 1115 . 3 and 9 - 1115 . 6 ) . <br /> g . Before any hazardous materials/waste can be stored or used onsite , the owner/operator must <br /> report the use or storage of these hazardous materials in the California Environmental Reporting <br /> System ( CERS ) at cers . calepa . ca . gov/ and comply with the laws and regulations for the programs <br /> listed below ( based on quantity of hazardous material in some cases ) . The applicant may contact <br /> the Program Coordinator of the Certified Unified Program Agencies ( CUPA ) program , Melissa <br /> Nissim ( 209 ) 468 . 3168 , with any questions . <br /> 1 . Any amount but not limited to the following hazardous waste : hazardous material spills , used <br /> oil , used oil filters , used oil - contaminated absorbent/debris , waste antifreeze , used batteries or <br /> other universal waste , etc . — Hazardous Waste Program ( Health & Safety Code ( HSC ) Sections <br /> 25404 & 25180 et sec . ) <br /> 2 . Onsite Treatment of hazardous waste — Hazardous Waste Treatment Tiered Permitting <br /> Program ( HSC Sections 25404 & 25200 et sec . & California Code of Regulations ( CCR ) , Title <br /> 22 , Section 67450 . 1 et sec . ) . <br /> 3 . Reportable quantities of hazardous materials — reportable quantities are 55 gallons or more of <br /> liquids , 500 pounds for solids , or 200 cubic feet for compressed gases , with some exceptions . <br /> 4 . Carbon dioxide is a regulated substance and is required to be reported as a hazardous material <br /> if storing 1 , 200 cubic feet ( 137 pounds ) or more onsite in San Joaquin County — Hazardous <br /> Materials Business Plan Program ( HSC Sections 25508 & 25500 et sec . ) . <br /> 5 . Any amount of hazardous material stored in an Underground Storage Tank — Underground <br /> Storage Tank Program ( HSC Sections 25286 & 25280 et sec . ) . <br /> • If an underground storage tank ( UST ) system will be installed , a permit is required to be <br /> submitted to , and approved by , the EHD before any UST installation work can begin . <br /> • Additionally , an EHD UST permit to operate is required once the approved UST system is <br /> installed . <br /> PA- 2100164 & PA - 2200028 — Conditions of Approval 4 <br />