Laserfiche WebLink
50mm min — ULTRAGARD PVC GLAD METAL COPING OR <br /> TYP. <br /> a PJER PRESTO <br /> REQUIREMENTSCf 'FASTENED <br /> SEALANT ON UNDERSIDE - <br /> _ (N) LIGHTING ELEMENT I ULTRA"Fd:)P,�-_MEMBRANE FLASI-Im'G DURO-LAST TWO-WAY VENT <br /> (N) LED PARAPET - BY OTHERS WITH PREFABRICATED SKIRL <br /> LIGHT BAND, BY ' q �g Ar 1'TA INTERMEDIATE ATTACHMENT <br /> Mq <br /> OTHERS / WITH <br /> i ACCEPTABLE <br /> ' 5 degree slope FASTENERS NOTES 9 fiND TJUTE. <br /> (N) METAL / I 1/2' (40w)MINIMUM <br /> FLASHING (N) SHIM CONTINUOUS UELD FACTORY A-TOR <br /> SYSTEM TO / \ Is'(41�) cF RE �`Pp` er"E VENT SKIRT <br /> MATCH MG-2 1 100mm min 50mm min MAX FULTR44ARD PVC MEMBRANE <br /> UALpTRAG�ARDp pP�VC MEM15RANE - <br /> I 2ETAIL OF FLASHING SADDLE Sf'ECrelCATIONB oA°NL <br /> I I ATI DECK <br /> ` i� FRAMING <br /> \ fl <br /> (N) SEALANT \ / °$cL3 )'o MA ° <br /> ARCHITECT <br /> FLEXIBLE FLASHING TAPE NOTES: <br /> FLEXIBLE FLASHING TAPE COVEREIWG A MINIMUM OF 1. DETAILS TO BE USED IN CONJUNCTION WITH GUIDE SPECIFICATIONS CONTAINING REQUIREMENTS FOR SCOTT GIBBON ARCHITECT INC. <br /> (N) GEMENT [DRESSED UP AND SECURELY 200mm OF THE BLAUSTRADE NAILER5, INSULATION,SLIPSHEETS, ETC. NOTE l: INSTALL ONE VENT FDR EVERY 1000 SQUARE FEET OF SINGLE PLY DECK 2540 ZANELLA WAY SUITE#60 <br /> PLASTER EXTERIOR N �� ADHERED TO Bl11LDER5 WRAP 2. ULTRACsARD i'VG SEALANT IS REQUIRED ON ALL CUT OR NON-ENCAPSULATED EDGES OF MEMBRANE. VENTS SHALL BE EVENLY SPACED BETWEEN ROWS OF FASTENING TABS <br /> FINISH, TVP. AT REAR OF CAVITY REINFORCED MEMBRANE. THIS INCLUDES FACTORY CUT MEMBRANE. CHICO, CA 95928 <br /> � � _ ACROSS THE ROOF. <br /> ` TIMBER PACKER 3. IN NEW CONSTRUCTION ACCEPTABLE SUBSTRATES INCLUDE EXTERIOR GRADE PLYWOOD, POURED <br /> OR PRECA5T CONCRETE,CEMENT BLOCK OR MASONRY WALLS. NOTE 2: GUT A l-INCH HOLE THROUGH DURO-LAST MEMBRANE FOR VENT P: 530 / 343-7557 <br /> CAPPING d,ON REROOFING PROJECTS AN ACCEPTABLE ASPHALT BARRIER MUST BE INSTALLED OVER THE INSTALLATION AND INSTALL FEET UNDER MEMBRANE. DO NOT FASTEN VENT TO F: 530 / 343-7447 <br /> FLASHING EXISTINCs FLASHINGS To FULLY DIVORCE THE ULTRAGARD PVC FLASHING MEMBRANE FROM ANY DECK- <br /> BUILD <br /> ING WRAP INCOMPATIBLE MATERIALS. <br /> (N) FALSE PARAPET CAVITY BATTEN A� <br /> � IV CAP TO MATCH MEMBRANE WALL COVERING TWO-WAY BREATHER VENT NOT USED ���� <br /> BUIDINC� WRAP g ,1 .... � ,I 5 11 - H <br /> SCOTT <br /> (N) LIGHTING ELEMENT DETAIL N.T.S. TYPICAL SCALE. 6 - 1 -0 - SCALE: 314 - 1 -0 * GIBS N <br /> - BY OTHERS CAVITY BATTEN <br /> REFER TO DETAIL 6010 FOR TAB SPACING- BLDG. PAPER 4 No. 8327 <br /> (N) HOUSING <br /> Zd RE .: 1 0' <br /> (N) ADJUSTMENT CEMENT PLASTER ROUGH SAWN PLYWOOD 7 <br /> EXTERIOR FIN15H PER t. <br /> mV- N <br /> BRACKET 16 GA. STEEL LEVATIONS <br /> (N) SCREWS FOR SCALE: N.T.S. ROOFING MATERIAL UP <br /> - SETTING VERTICAL DURO-LAST FACE OF WALL <br /> — i PARAPET & BALUSTRADE - SADDLE INSTALL PREF4BRiGATED <br /> � � � 4 STACK FLASHING REVISIONS <br /> TYPICAL FLASHING AT PARAPET TO VERTICAL WALL <br /> 8 INCHES 4' MIN CHECK <br /> SINGLE PLY PARAPET MIN, <br /> PLAN <br /> REVDATE: A05/06/2016 <br /> I GROMMETTED WALL FLASHING. DECK 4 CANT STRIP REVDATE: <br /> ` FASTENER NOTE: DIFFERENT USES FOR THE 6X6 INSIDE 1 PAIR OF COMPOSITE <br /> AND OUTSIDE CORNERS. REMEMBER TO KEEP DRAIN RINGS PLACED DURO-LAST SEALANT PLYWOOD SHEATHING OVER <br /> THE EMBOSSED SIDE OUT ON TAN AND THE F <br /> / AS LOW INTO DRAIN SHAPED 2x ID 16 O.G. - OR REVDATE: <br /> SMOOTH SIDE OUT ON WHITE AND CRAY. PIPE AS POSSIBLE SHAPED CONTINUOUS FOAM <br /> (N) 2x WOOD (N) 2x TOP PLATE, BUTTERFLY CORNERS ARE SPECIAL ORDER BLOCKING. <br /> BLOCKING, TYP. i SEE STRL. p° p tQi / ONLY. REVDATE: <br /> 6X6 BUTTERFLY CIER 6X6 Nsip %' (N) SINGLE PLY ROOFING SYSTEM <br /> (SPECIAL ORDER ONLY) COI�JER <br /> (N) GEMENT PLASTER 6x6 OUTSIDE TYPICAL <br /> ' COWER(TYP REVDATE: <br /> EXTERIOR FINISH � -=- - <br /> ROOF SHEATHING <br /> NOTE 1: MEMBRANE MUST BE FASTENED AROUND THE PERIMETER OF THE DRAIN <br /> . - 1 <br /> l <br /> MAY USED IN ACE OF PATTERN AS THE FI MEMBRANE, NO SS THAN ONE <br /> NOT I: FASCIA A AN COYER BE ED PL WITH THE SAME FASTENING P ERN E ELD LE <br /> E BAR D E -- .-... <br /> EXTERIOR GRADE .'� <br /> TERMINATE SAME AS THE TERMINATION BAR. FASTENER PER DRAIN. <br /> r PLYWOOD SHEATHING <br /> PARAPET FLASHINGS. NOTE 2: THE SUBSTRATE MUST BE FREE AND CLEAR OF DEBRIS AT AND NOTE 2: THE OPENINGS IN THE DRAIN RINGS MUST FACE IN OPPOSITE DIRECTIONS. FILL ALL CRICKETS AND BRACED <br /> SEE DTL. 20/A32 AREAS W/BLOWN INSULATION <br /> BELOW THE TERMINATION POINT. SEALANT AND DRAIN RINGS ARE TO MATCH LOCATIONS. <br /> PARAPET LIGHT BAND 17 INSIDE WALL TERMINATION OVERFLOW DRAIN CRICKET FLASHING 2 <br /> LAPS � FACTORY ,I _ I „ lo <br /> ++ _ + +, � " _ '_ <br /> REFER TO EXTERIOR ELEVATIONS SCALE: N,T,S, WELDS. TYPICAL IF REQ'D <br /> SCALE: 6 - 1 -0 TYPICAL SCALE: 6 - 1 -0 TYPICAL SCALE: 3 1 0 <br /> NOTE: THE DECK <br /> NOTE: Take EDGE OF BUILDING MEMBRANE MAY BE USED 1 PLATES t FASTENERS BLDG. PAPER <br /> extra care not FOR FLASKING WHICH ARE PER MFG SPECS. BLDG. STRUCTURE <br /> to place tab 6' Factory tab PERPENDICULAR TO THE <br /> sea ler where LAP DIRECTION. 15 EXT_ GEMENT PLASTER / EXTERIOR ROUGH <br /> Held welds WI,� 9'Min. x FASTEN INTO DEcK INTO - I ` SAWN PLY. WOOD AS OCCURS, TYPICAL ` p �, Lu C'4 <br /> need to be _6 Longq� WALL TIGHT TO CORNER <br /> Roll GoOZys r------------- <br /> done. ,------------- I - FLASHING oe L4r <br /> � 6" Factory Tab <br /> DECK-TO-WALL EXPANSION JOINT <br /> I; zx STUD WALL <br /> COPING 111 <br /> ROOFING MATERIAL UP <br /> TYPICAL SCALE: 6" = V-0" <br /> 4' MIN FACE OF WALL <br /> �' FOAM CORNICE <br /> QCANT STRIP v <br /> (N) NEOPRENE 24 GA. GAL FLASHING PAINT ; d MULTIPLE-PLY BASE FLASHING, EXTEN 4' CANT STRIP 3 GOAT CEMENT PLASTER I' I 0 o) <br /> COMPRESSION SLOPE '---- -+ z UP AND OVER PARAPET PER MANUFR J� <br /> STRENGTHENING BEAD I FOLD FLAP OF COPINGZ <br /> 1. DOWN THE CENTER OF 3 WIDE (MIN.) ROLL GOODS,MECHANICALLY FASTEN 3 SQUARE METAL P,QD. AS W INTO JOINT 0 END. 0 q <br /> 70o) <br /> Q <br /> PLATES WITH A DURO-LAST FASTENER FASTENER FREQUENCY WILL BE DETERMINED BY THE PULL occuRS I �t ! t PLYWOOD SHEATHING OVER 2x4 WOOD EDGE STIFFENER <br /> RESISTANCE CHARTS FOR THE ROOF SYSTEM, I I; SHAPED 2x 16 O.G. 0 <br /> ' `~ MULTIPLE-PLY BUR 5Y5TEM 'I' BLOCKING 9 MID POINT. '° 6' WIDE G.SM. GOPING/ROOPG <br /> 2. POSITION THE DECKSHEET TO ITS LOCATION AND BEGIN TO ATTACH IT ACCORDING TO THE ROOF[ SITION FLASHING. U <br /> m = _ , ,` TAPERED EDGE INSULATION <br /> SPECIFICATIONS. - , 3 I'' <br /> r„ I AS OCCURS, TYP. <br /> 3. APPLY THE TAB SEALER OVER THE MECHANICALLY ATTACHED ROLL GOODS AND THE BOTTOM � BUILT-UP ROOFING (a �- ff � � <br /> SIDE OF THE DECK SHEET WHERE THE ROLL CaOOD WILL COME INTO CONTACT WITH THE BACKSIDE OF DONT. 20GA GAL <br /> THE DECKSHEET. METAL CLEAT W/2' - I --�-�- e <br /> - 4' 4' .;. ROUGH SAWN PLY. WD. <br /> FASTENERS THRU OR CEMENT PLASTER, SEE SPEC'S <br /> •4. SMOOTH THE MEMBRANE INTO THE ROLL GOODS, BE[W:s SURE TO MOVE ALL AIR POCKETS. + ---- __ <br /> _��yfi_ _- y�.-._.--.y_._-_r_�_r <br /> CONTINUE THIS PROCESS FOR EACH ADDITIONAL STRIP OF ROLL GOODS INSTALLED. NEOPRENE WASHERX (N) 2X NAILER <br /> I <br /> iE E <br /> - A <br /> C" N ICU A 16 O.G. BOTH SIDE ,- (N) ROOFING ' <br /> - SHE <br /> t METAL (G.S.MJ END WALL CAP <br /> Y WH THE FASTENING TABS OF THE DECK5HEET RUN PERPENDICULAR L R ' <br /> 5. THIS IS TO BE USED ONLY ERE <br /> -v TO A ROOF EDGE. '' 1^L,4SHINC-c �------- � .....................................................�,.�........................ {_ .�. <br /> c�I OPTION FOR EDCLaE RE 'MNtS(1�'-TABS) SEALANT TYP. ROOF SHEATHING SCALE: 3" 1'-0° <br /> BOTH SIDES ALSO 8 <br /> �I SINGLE PLY ROOF- EDGE DETAIL 2x STUD WALL REFER To _ PARAPET FLASHING EXTERIOR WALL CRICKET FLASHING COPING END DETAIL <br /> Q <br /> IF- <br /> 18 PROVIDE EXPANSION JOINTS W/OVERLAPS d SEALANT AS " - 1'- PLASTER 1 PLY.WD. TERMINATION TYPICAL SCALE: 314" = 1'-0" O <br /> o 11 7 <br /> DETAIL N.T.S. RECOMMENDED BY S.M.A.CN.A. TYPICAL SCALE. 1 112 0 FLASHING AT CEM. S <br /> �I 'GAF' WHITE SINGLE PLY ROOFING SYSTEM, <br /> COPING DETAIL AT PARAPET CAP ATTACH PER MFR SPECIFICATIONS, TYP. CUTTING <br /> DING ALSO <br /> cnI _________ _______ _ REFER TO _ v <br /> i TYPICAL SCALE: 3" = 1'-0" <br /> 15 <br /> d' x 8' INSULATION 4' x 4` INSULATION PONDING ADHESIVE <br /> c PER MFR SPEC'S <br /> - Folded-back <br /> PVC ° 0 O 0 0 0 o TYP. --------- + , _ ' - <br /> I�I membran 0 0 0 0 0 0 ----- -- --------- <br /> C) o o ° 6' 0 0 0 0 �' STANDING SEAM Z <br /> o O <br /> I o 0 0 <br /> 0 <br /> Caj Sealer (2-Side 0 <br /> I Application - F' Per 6' 6' <br /> o ga on) Item 01119 V <br /> 9' wide generic 2' x 4' INSULATION 4'X8' GYPSUM OR DENS-DECK@ <br /> Lu paint roller °' Q <br /> 01 O O O O .;:w FF, <br /> Y 6' Fastenin tab attached <br /> Wlth a 3' S care Metal 0 0 0 0 6, 0 0 <br /> CF) a� '`• ___ <br /> � Plate and L Fastener o 0 0 0 � o 0 <br /> m 2' Installed on center of tab. o 0 o FASTENERS AND <br /> I <br /> CD Approved J0 PLATES PER MFR :;` �IvlO ,. 0 DATE: 12/02/2015 <br /> C° Insulation or I7" 6' SPECS, TYP. <br /> �I re-cover board. <br /> CN NOTE l: STAGGER SHEETS 50% FROM ROW TO ROW FOR EFFECTIVE ROOFDEGK / DENSDECK 14 1�0 1-1 1 cB JOB N O. -15.086 <br /> N �, FASTENING. TYP. _ _ _ _ EXTERIOR � }{::`f} ROOF WELL <br /> NOTE 2: THESE FASTENING PATTERNS ARE TO BE USED WITH <br /> c- 04 SINGLE PLY ROOF- SYSTEM MECHANICALLY FASTENED SYSTEMS ONLY. ROOF INSULATION AS OCCURS ROOF DETAILS Q <br /> Q SIM. TYP, AS OCCURS SINGLE PLY ROOFING A <br /> ADHESIVE APPLICATION <br /> Co <br /> -0 '57 A3 SINGLE PLY ROOF ADHES1 <br /> IVE DETAIL INSULATION & RECOVERY BOARD SINGLE PLY ROOFING SYSTEM PARAPET TOP CAP FLASHING NOT USED • <br /> 16 „ III 12 _ 8 _ III 4 <br /> 1 " - I_ " = 1 - JOINTS SCALE: 3" - 1'-0 - SCALE: 1 1/2" - 11-01, <br /> DETAIL N.T.S. FASTENING TYPICAL SCALE. 6 1 0 TYPICAL SCALE. 314 0 TYPICAL AT LAP JO N S <br /> ALL DRAWINGS&WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT&THE SAME MAY NOT BE DUPLICATED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHT"SCOTT GIBSON ARCHITECTS"ALL RIGHTS RESERVED. <br />