My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0085186_SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
5774
>
2600 - Land Use Program
>
SR0085186_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2022 2:33:48 PM
Creation date
5/17/2022 2:52:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0085186
PE
2602
STREET_NUMBER
5774
Direction
E
STREET_NAME
CHEROKEE
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
08715035
ENTERED_DATE
4/22/2022 12:00:00 AM
SITE_LOCATION
5774 E CHEROKEE RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />LOGE 2211 Page 6 <br /> <br />feet. When necessary after measuring the water level, the hole was refilled with water <br />to a level of approximately six inches above the bottom of the hole. <br />Percolation Test Results <br />The completed percolation test form is included in Appendix 3 of this report. The form <br />was signed by Mr. Ahmed and indicates a percolation rate for the hole based on the <br />final water drop observed. <br />Per San Joaquin County Environmental Health Department’s definition, a shallow <br />percolation test hole has a depth between 18 and 42 inches; a satisfactory percolation <br />rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br />or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br />percolation test hole must demonstrate a satisfactory percolation rate within the <br />proposed septic system disposal field. <br />Details and results of the percolation testing are summarized in the following table. <br />Table 2. Percolation Test Summary <br />Test No., <br />Date Tested <br />Percolation Test <br />Depth (ft.) <br />Percolation Rate <br />(minutes/inch) <br />Test Duration Comments <br />(see notes) <br />P1, <br />4/7/2022 <br />Shallow Test <br />2.51 31.25 4 hr. Satisfactory perc. <br />rate1 <br />Note: A satisfactory percolation rate for a “shallow” test is greater than 1 but less than or equal to 60 minutes per <br />inch. <br /> <br /> <br />Discussion of Percolation Test Results <br />The soils near the proposed sewage disposal areas of the Site have demonstrated a <br />satisfactory percolation rate for the use of septic systems in accordance with the <br />requirements of the San Joaquin County Environmental Health Department. This <br />percolation test is considered representative of soils within a 100-foot radius of the test <br />location. <br />Discussion of Septic System Sizing <br />Septic system construction utilizing leach lines with seepage pits should follow the San <br />Joaquin County On-Site Wastewater Treatment Systems Standards (2017) where <br />applicable.
The URL can be used to link to this page
Your browser does not support the video tag.