Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> Q' <br /> "lI FCOUNTY Jasjit Kang , REHS , Director <br /> °14WO ��� Greatness grows dere . Muniappa Naidu , REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Michelle Henry , REHS <br /> Elena Manzo , REHS <br /> June 17 , 2022 <br /> James Otto <br /> LC Services <br /> 3887 N . Valentine Avenue <br /> Fresno , CA 93722 <br /> Re : Wine Country Station/7 - Eleven SR0085085 <br /> 1111 E . Kettleman Lane , Lodi , CA 95240 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Convert the diesel tank to E85 <br /> • Replace fill tube shut- off valve on the new E85 tank <br /> • Replace line leak detector on the new E85 tank <br /> • Replace the turbine pump and fill sump sensor on the new E85 tank <br /> • Replace the annular sensor for the new E85 tank <br /> • Replace the in -tank probe for the new E85 tank <br /> • Replace dispensers with conversion frames <br /> • Cold start the monitoring panel <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department , the San Joaquin Valley Air Pollution Control District , and the <br /> San Joaquin County Community Development Department for any applicable permits and <br /> requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust( slgov . org to arrange the following appointments ( a 48- hour <br /> notice is required for inspection appointments ) . <br /> a . Verification of the dispenser footprints contained by the under dispenser containment <br /> sumps ( UDCs ) . Any potential leaks from piping and fuel filters must drain directly into <br /> UDCs . <br /> b . Visual inspection of the piping within the dispensers <br /> c . Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume <br /> shut off. Verification of flapper functionality . Ensure that all pertinent tank charts and <br /> calculations are available for review at the time of inspection . <br /> d . Verification that ball float(s ) , if installed , do not interfere with the installed flapper valve . <br /> e . Leak detector test : leak detector must be tested to confirm that the device can detect a <br /> leak of 3 gallons per hour at 10psi . leak detector monitored line volumes shall be <br /> appropriate for the make and model of the installed leak detectors , and shall be verified <br /> at the time of installation . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468 -3420 F 209 464 -0138 1 www . sjgov . org/ehd <br />