Laserfiche WebLink
AA��_�NCONSTRUCTION <br /> TESTING SERVICES <br /> October 18,2021 <br /> Paul Schneider <br /> President and Managing Principal <br /> Siegfried <br /> 3428 Brookside Road <br /> Stockton, CA 95219 <br /> Subject: Percolation Test Summary Report <br /> Holly Commerce Center <br /> 20500 Holly Drive,Tracy,California 95376 <br /> Dear Mr. Schneider, <br /> Construction Testing Services (CTS) is pleased to present the results of the percolation testing performed <br /> on October 12,2021,at Holly Commerce Center located at 20500 Holly Drive in Tracy, California. Based <br /> on discussions with you and outlined in our Proposal for Percolation Testing, Holly Commerce Center, <br /> P20472, dated September 10, 2021, we performed percolation testing for two future buildings at the <br /> proposed Holly Commerce Center. The tests were performed in general compliance with the San Joaquin <br /> County Environmental Health Department(SJCEHD)guidelines for permitting and performing percolation <br /> testing for commercial structures,EHD 42-01-002 Revised 5/24/2021. <br /> Based on our review of the design layout for the Holly Commerce Center, Buildings H&I, prepared by <br /> Phelan Development, dated September 28, 2021, four(4)potential leach fields are identified and range in <br /> size from between 1,542.56 square feet.to 2,015.55 square feet. <br /> At each proposed leach field location one (1) percolation test was performed for a total of 4 tests at the <br /> project site. See Plate 1 for site vicinity and Plate 2 for test location details. <br /> Percolation Testing <br /> The field percolation test locations were selected by you, identified as PT-1, PT-2, PT-3 and PT-4, were <br /> each dug using a 3.5-inch diameter hand auger and drilled to target depths of approximately 48-inches <br /> below the existing ground surface.Following the drilling,the sidewalls of each test hole were scarified with <br /> a wire brush to remove any smearing of the walls which occurred during drilling. The depth of each test <br /> location was extended a few inches to allow space for the placement of a coarse sand bedding. The soil <br /> cuttings were visually inspected by a Certified Engineering Geologist and included approximately 1 to 2- <br /> 1/2 feet of coarse gravel and aggregate base and generally underlain by sandy lean clay and sandy silt. <br /> The test holes were drilled and constructed on October 11,2021. Twenty-four hours prior to testing the test <br /> holes were hydrated to ensure saturated conditions for testing. <br /> On October 12,2021,eight(8)test readings were taken at thirty-minute intervals at each of the four(4)test <br /> locations. Percolation rates of the subsurface soils were calculated from the field percolation readings. <br /> 4400 Yankee Hill Road,Rocklin,CA 95677•Phone(916)419-4747•Fax(916)419-4774 <br /> 2118 Rheem Drive,Pleasanton,CA 94588•Phone(925)462-5151•Fax(925)462-5183 <br />