Phelan Development Holly Master Plan - Buildings H & 1 <br /> 15188.000.006 Geotechnical Exploration <br /> seismic lateral earth pressure corresponding to an equivalent fluid pressure of 30 pcf for a yielding <br /> wall design. When considering seismic earth pressures for retaining walls, the recommended <br /> seismic earth pressure increment should be added to the active earth pressures provided above. <br /> Appropriate surcharge loads from buildings, hardscape, and vehicles should be incorporated when <br /> the surcharge loading is situated above a 1:1 (horizontal:vertical) line of projection extending up the <br /> rear base edge of the bottom of the footing. A uniform horizontal surcharge load of 50 percent of <br /> the vertical surcharge load should be assumed to act over the height of the wall. <br /> If adequate drainage is not provided, we recommend that an additional equivalent fluid pressure <br /> of 40 pcf be added to the values recommended above for both restrained and unrestrained walls. <br /> Damp-proofing of the walls should be included in areas where wall moisture would be problematic. <br /> Passive pressures acting on foundations may be assumed as 300 pounds per cubic foot (pcf) <br /> provided that the area in front of the retaining wall is level for a distance of at least 10 feet or three <br /> times the depth of foundation, whichever is greater. The friction factor for sliding resistance may <br /> be assumed as 0.25. The upper 1 foot of soil should be excluded from passive pressure <br /> computations unless it is confined by pavement or a concrete slab. Passive pressures should be <br /> reduced by 1/2 if used in combination with sliding friction. <br /> 8.2 RETAINING WALL DRAINAGE <br /> Construct either graded rock drains or geosynthetic drainage composites behind the retaining <br /> walls to reduce hydrostatic lateral forces. For rock drain construction, we recommend two types <br /> of rock drain alternatives. <br /> 1. A minimum 12-inch-thick layer of Class 2 Permeable Filter Material (Caltrans Specification <br /> 68-2.02F) placed directly behind the wall, or <br /> 2. A minimum 12-inch-thick layer of washed, crushed rock with 100 percent passing the %-inch <br /> sieve and less than 5 percent passing the No. 4 sieve. Envelop rock in a minimum 6-ounce, <br /> nonwoven geotextile filter fabric. <br /> For both types of rock drains: <br /> 1. Place the rock drain directly behind the walls of the structure. <br /> 2. Extend rock drains from the wall base to within 12 inches of the top of the wall. <br /> 3. Place a minimum of 4-inch-diameter perforated pipe (glued joints and end caps) at the base <br /> of the wall, inside the rock drain and fabric, with perforations placed down. <br /> 4. Place pipe at a gradient at least 1 percent to direct water away from the wall by gravity to a <br /> drainage facility. <br /> ENGEO should review and approve geosynthetic composite drainage systems prior to use. <br /> 8.3 BACKFILL <br /> Backfill behind retaining walls should be placed and compacted in accordance with Earthwork <br /> Recommendations contained in this report. Use light compaction equipment within 5 feet of the <br /> —NGE0 Page 120 December 13, 2021 <br /> Expect Excellence <br />