Laserfiche WebLink
Additional Site Assessment Report and Human Health Risk Screening Evaluation <br />www.arcadis.com <br /> 8 <br />• Naphthalene was detected in one of the eight primary samples at a concentration of 0.0634 mg/kg (B-16 from <br />5.5 to 6.0 feet bgs). <br />All reported TPH-g, TPH-d, BTEX, and naphthalene concentrations in soil were less than the applicable LTCP <br />(SWRCB 2012) residential screening levels and SFBRWQCB residential soil ESLs (SFBRWQB 2019), with the <br />exception of TPH-d. Concentrations of TPH-d exceeded the SFBRWQCB residential soil ESL (260 mg/kg) in five <br />of the eight primary soil samples. The exceedances are further addressed in Section 7. <br />5.2 Soil Vapor Analytical Results <br />The following section discusses the analytical results for TPH, VOCs, and fixed gases for soil vapor collected in <br />January 2020 and April 2022. <br />5.2.1 Total Petroleum Hydrocarbons and Volatile Organic Compounds <br />The TPH-g and VOC concentrations in soil vapor are summarized below: <br />• TPH-g was detected in both analyzed samples at concentrations of 140,000 micrograms per cubic meter <br />(µg/m3; B-13 at 5 feet bgs) and 14,000,000 µg/m3 (B-13 at 8 feet bgs). <br />• Benzene was detected in one of the three primary samples at a concentration of 2.1 J µg/m3 (B-16 at 5 feet <br />bgs). <br />• Ethylbenzene, toluene, and xylenes were not detected in any of the soil vapor samples. <br />• A total of 14 other VOCs were detected in the soil vapor samples. <br />All reported TPH-g and VOC concentrations in soil vapor were less than the applicable LTCP (SWRCB 2012) <br />residential screening levels and SFBRWQCB residential ESLs (SFBRWQCB 2019), with the exception of TPH-g. <br />Concentrations of TPH-g exceeded the SFBRWQCB residential ESL in both samples. The exceedances are <br />further addressed in Section 7. <br />5.2.2 Fixed Gases <br />Oxygen concentrations in soil vapor ranged from 0.85 percent (B-13 at 8 feet bgs) to 21 percent (B-16 at 5 feet <br />bgs and the associated duplicate). Nitrogen concentrations in soil vapor ranged from 9.3 percent (B-13 at 8 feet <br />bgs) to 96 percent (B-13 at 5 feet bgs). <br />Methane concentrations in soil vapor ranged from 0.040 percent (B-13 at 5 f eet bgs) to 80 percent (B-13 at 8 feet <br />bgs). Carbon dioxide concentrations in soil vapor parent samples ranged from 0.098 percent (B-16 at 5 feet bgs) <br />to 9.8 percent (B-13 at 8 feet bgs). Carbon dioxide was also detected in the duplicate sample. Helium was not <br />detected in any of the soil vapor samples; helium concentrations were within the acceptable leak limit of 5 percent <br />(refer to Section 3.2.3 for more detail on the helium leak test).