My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 9:33:30 AM
Creation date
5/31/2022 1:10:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0518288
PE
2351
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TLS-350R Interface Modules <br /> The TLS-350R monitoring console contains three compartments in which individual interface modules can be installed.Interface modules may <br /> be factory-installed in the console upon initial ordering,or ordered separately as spare modules to expand an existing system. <br /> Low Power Compartment(Limit eight per console,unless otherwise noted) <br /> Foran No. <br /> Factory <br /> Installed <br /> Modules Description Feature Compatibility(Where Applicable) <br /> 329356-002 Four-Input Probe Interface Module Series 8473 0.1 GPH Magnetostrictive Probe <br /> (Maximum three per console. Includes terminal Series 8463 Mag Plus Probe <br /> connector for one ground temperature thermistor for <br /> the volumetric line leak detector). <br /> 329358-001 Eight-Input Interstitial/Liquid Sensor Series 7943 Interstitial Sensor for Fiberglass Tanks and <br /> Interstitial Sensor for Steel Tanks <br /> Series 7943 Piping Sump Sensor <br /> Series 7943 Hydrostatic Sensor <br /> 329357-001 Five-Input Vapor Sensor Interface Module Series 7943 Vapor Sensor <br /> 329399-001 Five-Input Groundwater Sensor Module Series 7943 Groundwater Sensor <br /> 329956-001 Eight-Input Type A Sensor Interface Module Series 7943 Solid State Discriminating Interstitial Sensor <br /> 329950-001 Six-Input Type B Sensor Interface Module Series 7943 Solid State Dispenser Pan and Containment Sensors <br /> 330843-001 Six-Input Pressurized Line Leak Interface Module Series 8484 Pressurised Line Leak Detection System Requires <br /> (one per console) TLS-350 Version 7.0 or higher software <br /> 329356-004 Eight-Input Smart Sensor Module Smart Sensors <br /> Requires TLS-350 Version 24.0 or higher software <br /> High Power Compartment(Limit eight per console,unless otherwise noted) <br /> Form No. <br /> Factory <br /> Installed <br /> Modules Description Feature Compatibility(Where Applicable) <br /> 329359-001 Four-Relay Output Interface Module — <br /> 329360-001 Two-Input/Two-Relay Output Interface Module — <br /> 329999-001 Pump Sense Interface Module Accepts up to four inputs <br /> 330374-001 Three-Output Pressurized Line Leak Controller Series 8484 Pressurized Line Leak Detection System <br /> Interface Module(Two per console) Requires TLS-350 Version 7.0 or higher software <br /> Communications Compartment(Limit three per console,unless otherwise noted) <br /> Form No. <br /> Factory <br /> Installed <br /> Modules Description Feature Compatibility(Where Applicable) <br /> 330149-002 SiteFax Interface Module Allows hookup to most remote facsimile,modem or teletype <br /> equipment. Requires TLS-350 Plus Version 3.0 or higher software <br /> 330586-001 RS-485/232 Dual Port Communications Module — <br /> (Slot 4 only) <br /> 330148-001 RS-232 Interface Module with Auxiliary Port Provides two 25-pin D-connectors for data transmission to P.O.S. <br /> (Slot 4 only) terminal,printing device or computer <br /> 329362-001 RS-232 Interface Module Provides a 25-pin D-connector for data transmission to PO.S. <br /> terminal,printing device,or computer <br /> 330000-001 Remote Printer Interface Module Provides a 25-pin D-connector for data transmission to a remote <br /> serial printer <br /> 330883-001 WPLLD Communications Module — <br /> 330020-425 Ethernet—TCP/IP Communications Module Provides connectivity to local and wide area networks(LAN/WANS) <br /> Temperature Range—Operating:32F to 118F(0°C to 45°C)Storage: 15°F to 118°F(10°C to 45°C) <br /> AO\ ©2004 Ueeder-Root Company • 125 Powder Forest Drive • Simsbury,CT 06070 • USA <br /> r► VEEDER-ROOT Telephone:860-651-2700 • Fax:860-651-2719 • www.veeder.com <br /> 1111111w;:� <br /> VR 13772 P/N 0576047-060 Rev.B VR 7/2004 Printed in USA <br />