My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 9:33:30 AM
Creation date
5/31/2022 1:10:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0518288
PE
2351
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ARID PERMEATOR INSTALLATION NOTES PERMEATOR INSTALLATION TASKS: <br /> 1. MECHANICAL: PERMEATOR REQUIRES A 2 INCH LINE FOR FEED, RETENTATE(EXHAUST) AND PERMEATE RETURN LINES. ARID SUPPLIES 2, 6 INCH ANSI 125, 4-BOLT 1.MOUNT ELECTRICAL CONTROL CABINET WITHIN CONTROLLER ENCLOSURE. �p <br /> FLANGES; INSTALL CONTRACTOR PROVIDES THE MATING 6 INCH FLANGES.THE TWO(2)FEED AND PERMEATE LINES ARE PIPED TO THE VERTICAL VENT RISERS USING A"T' Z <br /> AND 90 DEGREE ELBOW AS A"SWING JOINT". ARID ALSO RECOMMENDS THAT LOW RESISTANCE, STRAIGHT THROUGH BALL VALVES BE INSTALLED BETWEEN THE FLANGES 2.ENSURE PRESENCE OF A DEDICATED TELEPHONE LINE JACK WITHIN 6 FEET OF ELECTRICAL CONTROL PANEL. F Q <br /> AND VENT RISERS ON THE FEED AND PERMEATE RETURN LINES.TYPICALLY,THE RETENTATE(EXHAUST)LINE IS RUN PARALLEL TO THE VENT RISERS AND SUPPORTED WITH 3.BRING MAIN POWER TO CONTROL PANEL AND POWER/CONTROL SIGNAL WIRING FROM CONTROL PANEL TO PERMEATOR aa rr <br /> UNI-STRUT.IN ADDITION,THE TOP OF THE RETENTATE LINE IS FITTED WITH A RAIN-CAP(NOT A P/V VALVE). J N Q t <br /> LOCATED ALONGSIDE VENT PIPES. POWER IS 208 V J <br /> a <br /> THE FOUR LEGS ON EACH PERMEATOR ARE FORMED WITH HOLES TO ACCOMMODATE RED-HEAD MOUNTING BOLTS TO THE CEMENT PAD LOCATED ADJACENT TO THE VENT WIRING IS / 60 HZ /24 VOLT DC (4-20 MA); SIGNAL WIRES SHOULD BE S3HIPHASE; 20 AMP SERVICE REQUIRED. CONTROL <br /> ELDED 18 OR 20 AWG CABLE; 1 PAIR, OR 2 <br /> PIPE RISERS. CONDUCTORS PER EACH SENSOR SIGNAL. PEREQUIPPED WITH DATA LOGGER REQUIRES 3 SIGNALS OR 6 Ul Z <br /> USED F Z un LL <br /> CONDUCTORS.SEPARATE CONDUITS SHOULD BE USED FOR POWER AND COMMUNICATION CABLES,RESPECTIVELY. ZZ 0 wa W <br /> 2.NON-HYDROCARBON SENSOR VERSION--ELECTRICAL: ARID RECOMMENDS USING TWO(2)RIGID CONDUITS.THE FIRST CONDUIT IS FOR RUNNING 3 PAIRS CONDUCTORS) Q Z k Z <br /> OF SHIELDED 16 GAUGE CABLE.THE CONTROL CIRCUIT VOLTAGE IS 24 V DC,AND CURRENT IS 4-20 MILLIAMPS.THE SECOND CONDUIT IS FOR RUNNING POWER <br /> ER WIRES: 208 4.POUR 5 FT. X 5 FT. CEMENT PAD ALONGSIDE VENT PIPES AND MOUNT PERMEATOR WITH 4 BOLTS THROUGH THE O 4 Q`V JJ <br /> V,3 PHASE,60 HZ, 20 AMPS; 3 CONDUCTORS(12 OR 14 AWG OR LOCAL CODE)PLUS ONE GROUND WIRE.THESE CONDUITS WILL RUN BETWEEN THE CONTROL PANEL EXISTING SUPPORT STAND LEGS. PERMEATOR MAIN CABINET WEIGHT IS APPROXIMATELY 750 LBS AND FOUR LEGGED Q y¢N O <br /> LOCATED IN THE CONTROLLER ENCLOSURE HOUSING THE SUBMERSIBLE TURBINE PUMP ELECTRONICS AND A JUNCTION BOX LOCATED ON THE PAD ADJACENT TO OR BASE MEASURES 36 INCHES X 36 INCHES. W J CS U N <br /> MOUNTED ON THE PERMEATOR. THE JUNCTION BOX ON THE PAD WILL COMMUNICATE WITH THE MOTOR OF THE PERMEATOR AND AN ADDITIONAL PERMEATOR MOUNTED <br /> JUNCTION BOX THROUGH A FLEXIBLE BRANCH CONDUIT OF 3/4 INCH DIAMETER. (TYPICALLY,THESE CONDUITS MAKING FINAL CONNECTIONS BETWEEN RIGID CONDUIT AND &CONNECT 2 INCH FEED AND RETURN PIPING TO VENT RISERS; PROVIDE LOW RESISTANCE("STRAIGHT-THROUGH")BALL WW p <br /> MOTOR/CONTROL WIRE JUNCTION BOXES ARE WATER-TIGHT FLEXIBLE CONDUITS,RATED FOR HAZARDOUS AREAS) VALVES FOR ISOLATION AND SHUT-OFF ON THE FEED AND PERMEATE RETURN LINES, AND PIPE VAPOR RETURN LINE a a 0 In 8 <br /> TO LOW GRADE PRODUCT VENT. PLACE A 2 INCH "T" BETWEEN THE FLANGE CONNECTION AND THE ISOLATION BALL O <br /> THE ELECTRICAL CONTROL PANELS ARE 18" WIDE X 20" LONG X B" DEEP AND ARE MOUNTED IN THE CONTROLLER ENCLOSURE HOUSING THE PUMP ELECTRONICS. THE VALVE ON THE RICH VAPOR RETURN LINE. ENSURE MINIMUM SLOPE OF 1/4 TO 1/8 INCH PER FOOT FROM b & 0 <br /> CONTROL PANEL HAS AN INTEGRAL POWER SUPPLY FOR THE CONTROL CIRCUITS, AND ACCEPTS THE 208 V,3 PHASE, 60 HE MAIN POWER. (PERMEATOR REQUIRES A 20 PERMEATOR TO VENT RISERS. Q C) <br /> AMP CIRCUIT). o <br /> 6.CONNECT EXHAUST VENT TO PERMEATOR AND SUPPORT BY RUNNING PARALLEL TO EXISTING VENT RISERS, AND CAP <br /> INSTALL RATED LOCAL DISCONNECT SWITCH LOCATED NOT WITHIN 18"HORIZONTALLY FROM THE UNIT AND AT LEAST 18"ABOVE GRADE FOR EQUIPMENT MAINTENANCE PURPOSES.INSTALL THE EXHAUST VENT WITH A FRESH AIR VENT CAP. <br /> ONLY IF REQUIRED BY AUTHORITY HAVING JURISDICTION. a F <br /> 7.ARID PERSONNEL TO OVERSEE WIRING TERMINATION CONNECTIONS WITH ELECTRICIAN IN THE FIELD. <br /> BE TOR UNIT CIRCUITRY SHALL BE TIO INTO THE EMERGENCY SHUTOFF SWITCH CIRCUITRY SUCH THAT IN THE EVENT OF AN EMERGENCY SHUTDOWN,POWER WILL BE CUT TO THE <br /> CONTROL <br /> 4 <br /> CONTROL PANEL IN THE CONTROLLER ENCLOSURE AND TO THE MOTORS AT THE PERMEATOR UNIT. <br /> SEE SHEET T6-1 <br /> FOR PIPING DETAILS <br /> OIL FILL CAP DPW 72N VENT CAP 21 VENT <br /> R <br /> INSTRUMENT OUNTINPEMCO WHEATON CAP 20 <br /> 25M'%13'%G 1/4'LATTHK.E PHEATR ATMOSPHERIC CAP 16 <br /> CLEAN AIR VALVE JRAUD-002 <br /> 'r,1 MEMBRANE MODULE <br /> 18 <br /> PRESSURE RELIEF VALVE n <br /> N <br /> REOOPOB VACUUM PUMP W <br /> / O <br /> - 3ym <br /> HP TEXP RELIANCE MOTOR O o 3 <br /> r ENCLOSUREW/LOCKABLE O AIR AN ?�QYQ= <br /> DOORS AND VENTS O OUTLEE, o Jq <br /> P NET N N O <br /> W N <br /> u V � <br /> 361n 4.51n <br /> 41.9]Sin OVERALL <br /> ,IN <br /> 31n <br /> + I <br /> 21 g 0 <br /> 0 5/8"THRU <br /> SECTION A-A O <br /> SCALE 1 4p O p <br /> FOOT PADDETAIIBOTH PIPES <br /> OIL FILL CAP 4 L- S O <br /> GROUND VS"EPER <br /> CONNECTION OT DOWN <br /> VENT <br /> o a <br /> ET(RIGS casouNE/alre b '. <br /> RETURN TOq ANK�,2'-1254 <br /> N81 .F.BY.G C, /. <br /> 2"BALL VALVE <br /> 62 < pdp <br /> (ttP.OF 2) INLET(LEAN II tq cAL14 5N <br /> OIL SIGHT G cASOUNENAIRSISS <br /> § u Y <br /> OIL DRAN 3RD 125# <br /> FANBI o 0 0 0 0 p k e <br /> F.F. <br /> Bv..c. <br /> w °a <br /> mmR <br /> e <br /> e � � <br /> 34m 1m - p <br /> 9.95]33i C <br /> 30]]16535IN DRIP P DRAIN O <br /> (PLUGGED) C '; <br /> NOTE: ARID TECHNOLOGIES ATO BE Y <br /> 3.330]OB]in LOCATED IN CONFORMANCE WITH IEH MANUFACTURE <br /> FACTURERS 3 ✓R <br /> NSN MANUAL,CARD EXECUTIVE ORDER AND <br /> ]1/8' ALLL AlPEI APPLICABLE STATE AND LOLL CODES. I■� <br /> MOTE'ADDITION&SCREEN WALL OR CONSTRUCTION m 8 <br /> R DUIRED LOCAL <br /> W//N'E'SP4% REQUIREMENTREQUIREM"'S PREHGHOWNTEN TTHISINpMUNML MOUNTING <br /> DRAIN(PLUGGED) <br /> MEMBRATOR'R RE0040B VACUUM PUMP L 3HP-DI MOTOR, <br /> S <br /> — 1A MEMBRANE MODULE HOUSING,&36'TALL STAND-DIMENSIONAL p <br /> 3m-11` I SIM �+\—'X0 <br /> 5/8" In N <br /> TURN {p <br /> r <br />