Laserfiche WebLink
Presto, Carol [EHD] <br /> From: Austen Downey <adowney@jonescovey.com> <br /> Sent: Wednesday,August 31, 2022 7:26 PM <br /> To: Ernest, Frederick [EHD];Joseph Malcolm <br /> Cc: Steven Nelson; Chris Wright; Alexia Inigues; Kayleen Burnett; <br /> environmental compliance@costco.com; Presto, Carol [EHD];jiovanny <br /> preciadoelectric.com;Jason Hermosillo;Jessica Brandi <br /> Subject: RE: 3250 W Grant Line New Install/Retrofit Questions <br /> Good evening Frederick. My apologies for the delayed response I just got back to my computer from the site. Below <br /> please find my responses to your questions in red. <br /> Thank you, <br /> ,4aJ&a Deaw ql <br /> C�� JONES COVEY GROUP, INS <br /> 9595 Lucas Ranch Road#100 <br /> Rancho Cucamonga,CA 91730 <br /> (888-)972-7581 Office <br /> (714)313-7633 Cell <br /> (909)484-0300 Fax <br /> ADowney@JonesCovey.com <br /> From: Ernest, Frederick [EHD] <fernest@sjgov.org> <br /> Sent: Wednesday,August 31, 2022 4:08 PM <br /> To:Austen Downey<adowney@jonescovey.com>;Joseph Malcolm <jmalcolm@jonescovey.com> <br /> Cc:Steven Nelson <snelson@barghausen.com>; Chris Wright<chris.wright@diamondzengineering.com>;Alexia Inigues <br /> <ainigues@barghausen.com>; Kayleen Burnett<kburnet@costco.com>; environmentalcompliance@costco.com; Presto, <br /> Carol [EHD] <cpresto@sjgov.org> <br /> Subject: 3250 W Grant Line New Install/Retrofit Questions <br /> Good afternoon, <br /> I had a couple of question concerning the onsite monitoring and operations for the tanks at 3250 W Grant Line in Tracy. <br /> Questions for the newly installed premium (91)fuel tank: <br /> • When was the fuel was placed in the tank? <br /> Fuel was transferred from the existing tank 3 ,previously premium tank, to the new tank 5 premium tank on Monday <br /> 8/29/2022. <br /> • How was fuel placed into the tank?Was a port used to receive fuel or was the spill bucket used to receive fuel? <br /> Fuel was purged from the dispenser via a purge hose through the spill bucket, down the drop tube, and into the tank. <br /> The purge hose was run into the tank itself. <br /> • When was the monitoring panel switched from the old panel to the new panel?What was the gap in monitoring <br /> between the changeover of the panel? <br /> The monitoring of the existing tanks was transferred from the existing Veeder Root to the new Veeder Roots on August <br /> 18th at which time the temporary wiring and conduit were removed and the sensors were connected via the permanent <br /> underground conduit and wiring.The interruption in monitoring was less than 30 minutes during the transition. <br /> • What sensors were being installed on 8/30?Were there any sensors that weren't already installed and <br /> operational by the time the fuel was transferred to the tank? <br /> 1 <br />