My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 9:33:30 AM
Creation date
5/31/2022 1:10:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0518288
PE
2351
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br /> HL0 <br /> Cn W <br /> J 0 0 <br /> SHORE TANK EXCAVATION PER OSHA REQUIREMENTS AND TANK MANUFACTURE Q <br /> Q <br /> INSTALLATION INSTRUCTIONS. REFER TO PROJECT SOILS REPORT AND CIVIL 0 <br /> DRAWINGS FOR ANY ADDITIONAL RECOMMENDATIONS. ALL SHORING IF REQUIRED o W J <br /> TO BE ENGINEERED AND PERMITTED UNDER SEPARATE PERMIT BY CONTRACTOR. Q W N V <br /> REFER TO ARTICLE 13200B OF PROJECT MANUAL. Z J Z L <br /> 0) <br /> LL <br /> B ~ Cj ~ Q Z <br /> 18 WIDE X 2" ALL z O Z Q U J <br /> SEE CIVIL SHEETS FOR T3-1 CONCRETE CROWN REINFORCED CONCRETE SLAB o U_ z 0 <br /> ADJOINING CONDITIONS MIN. (TYP.) SEE STRUCTURAL DRAWING w 0 Z 0 Q Q <br /> FOR SPECIFICATIONS N Q <br /> ocr !� <br /> \J <br /> c a_ (Z (Z <br /> z cr C ) O O <br /> V) a w v ccn ccW v,n a U <br /> LLJ <br /> o INSTALL FILTER FABRIC Q Qco <br /> > o o BACKFILL AT TANK HOLE (TYP.) o >o o <br /> -1c <br /> Z <br /> - O <br /> � '� m EXTEND CONTINUOUS FILTER 0 <br /> COMPACTED ALL GASOLINE FABRIC TO SLAB m m m m W <br /> SOIL TANK TOPS TO � � m <br /> C <br /> Q0 BE SET LEVEL � N <br /> o <br /> 3'-9" 71'-4" o czD <br /> 01 1 <br /> REINFORCED CONCRETE SLAB ABOVE SEE w 5'-g» FOURTH LIFT OF <br /> CONSOLIDATED BACKFILL, <br /> CIVIL DRAWING FOR SPECIFICATIONS <br /> Q FILL TO TOP OF TANK <br /> 40,000 GALLON DOUBLE WALL <br /> x FIBERGLASS TANK <br /> i � 2'-O" UL 1316 LISTED AND 2'-0" <br /> OUTLINE OF CONCRETE CROWN a_ METHANOL COMPATIBLE. <br /> 18" MIN. (TYP.) O Q 10'-6" 0.D. <br /> O ° 2'-g»THIRD LIFT OF CONSOLIDATED BACKFILL, <br /> 39"x10 3/4" DEEP WATERTIGHT (-F ° ° 1 ° TAMP BACKFILL BENEATH TANK <br /> 37 MANHOLE/LID ASSEMBLY FOR TURBINE ID TAG RECESSE ° <br /> 12 FLUSH WITH 'r3_3 ° ° SECOND LIFT OF CONSOLIDATED <br /> AND FILL SUMP ENTRY (TYP.) CONCRETE ° �° l '-O"—BACKFILL, TAMP BACKFILL BENEATH TANK <br /> PREMIUM UNL. 91 OCTANE OBSERVATION ° ° ° <br /> 40,000 GALLON �; ;;�, PORT (TYP.) 1 ,_0„ FIRST LIFT OF CONSOLIDATED BACKFILL, <br /> 1111 TANK 5 TAMP BACKFILL BENEATH TANK <br /> CD <br /> 25" MANWAY ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ** 1 -0 BED OF CONSOLIDATED BACKFILL, TAMP _ <br /> „ 25" MANWAY / / / / / / / / / / / / / / / / / BACKFILL BENEATH TANKA <br /> 34 16 D ,� /\\ \\j�\�j\ \ \j\\\ \\, \\/\\/ J <br /> 24" MANHOLE N <br /> ACCESS TO ANNULAR C-14 <br /> MONITOR CONC. DEADMEN UNDISTURBED Q W O <br /> 18"x8" (TYP. OF 2) T3_Z INSTALL FILTER FABRIC AT <br /> A BOTTOM OF TANK HOLE (TYP.) SOIL W > OD <br /> NOTE. <br /> 0 T5-2 J a! <br /> NOTE: FOLLOW UST MANUFACTURERS COMPLETE CURRENT GROUNDWATER IS ENCOUNTERED DURING O 0 <br /> N ' EXCAVATION FOR TANK INSTALLATION OR IF = W <br /> INSTALLATION INSTRUCTIONS. OSHA TYPE "C" SIMPLE SLOPE POTENTIAL EXISTS FOR SURFACE RUN-OFF _ <br /> INTO TANK PIT, CONTRACTOR SHALL STRAP Q <br /> SHOWN IN THIS VIEW THE TANKS TO THE DEADMEN AND BACK FILL O J � <br /> TO TOP OF TANKS IMMEDIATELY AFTER TANK 00) <br /> Tank Burial (Shored Hole Method) 0 <br /> � PLACEMENT, THEN CONTRACTOR SHALL � O Q <br /> C ENTIRELY FILL TANKS WITH WATER. THE ABOVE, O � <br /> TV SCALE: 3/8"=1 '-0" (TANK BALLAST & PLACEMENT BY FILLING WITH V _ <br /> WATER) SHALL BE DONE IN ONE CONTINUOUS <br /> NOTE: PROCESS. TANKS SHALL BE PUMPED DRY <br /> FILTER FABRIC (US FABRICS US200 OR DUPONT SF 40) IS REQUIRED AT BOTTOM AND ONLY AFTER FINAL BACK FILL AND CONCRETE <br /> COVER IS IN PLACE. ** FOR WET-HOLE <br /> SIDES OF TANK HOLE EXCAVATIONS, FOR ALL INSTALLATIONS. FABRIC MAY BE PINNED INSTALLATION THE TANK BACKFILL BEDDING <br /> TO SIDE OF HOLE WITH WIRE, ETC. SEAMS MUST BE LAPPED 1 ' MINIMUM. SHALL BE INCREASED FROM 12" TO 18". SEE <br /> NOTE: MANUFACTURER INSTALLATION INSTRUCTIONS LL <br /> DEADMEN ARE TO BE PRE CAST ABOVE GROUND AND LOWERED INTO EXCAVATION. FOR ADDITIONAL CLARIFICATION. <br /> BACKFILL MEDIA SHALL CONSIST OF CLEAN NATURALLY-ROUNDED AGGREGATE WITH PARTICLE SIZES <br /> NO LARGER THAN 3/4" WITH NO MORE THAN 5% PASSING A #8 SIEVE OR WASHED CRUSHED <br /> 0 STONE OR GRAVEL, WITH ANGULAR PARTICLE SIZES NO LARGER THAN 1/" WITH NO MORE THAN 5% <br /> TANK(S): PASSING A #8 SIEVE. REFER TO TANK MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR <br /> A New Tank Field Layout Plan SHALL BE UNDERWRITERS LABORATORY LISTED (UL-1316) AS CALLED FOR ON THE SITE SPECIFIC DRAWING OR AS DESIGNATED ON THE SUPPLEMENTAL CONDITIONS AND ADDITIONAL INFORMATION. SIEVE ANALYSIS OF BACKFILL IS REQUIRED. SUBMIT TO ARCHITECT & <br /> SHALL BE DOUBLE WALL TANKS OF FIBERGLASS REINFORCED PLASTIC (FRP) AS MANUFACTURED BY "CONTAINMENT SOLUTIONS". INSTALLATION OF TANKS AND PIPING T3 PROVIDE TO FACILITY INSTALLATION OVERSIGHT AGENT AT TANK SET.-1 SCALE: 1/4"-1 '-0" SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE INSTALLATION SPECIFICATION AS PROVIDED BY COSTCO WHOLESALE, AND MANUFACTURER'S INSTRUCTIONS. <br /> As-BuiltCD <br /> 09//101/201/2022 <br /> 1�HE5[OYE7 GROII P,IH[. 7:34:29 AM <br /> FESS/0 <br /> B � TURBINE END TANK TANK TANK =��� <br /> ALL FILL END #1 #2 #3 c <br /> GASOLINE TANKS T5-1 TYP. T6-1 REINFORCED CONCRETE SLAB B �E� HJ 67814 HAL P. GRUBB <br /> 4" DIA. FRP OR SCH. SEE CIVIL DRAWINGS 2 HIGH CROWN TYP. AROUND <br /> 35 40 PVC RISER ALL OPENINGS (SEE NOTE #2) T4-1 T4-1 T4-1 /, <br /> .o o.. A,> .. ^ .e. pa o C Cee e e .. a d d .a d °d P•ekp <br /> e <br /> e <br /> u <br /> a <br /> < a <br /> a e • <br /> a � 9TF SIV <br /> BRINE HYDROSTATIC RESERVOIR x �F CALF 05/27/22 <br /> TO TLS-350R BRINE HYDROSTATIC RESERVOIR <br /> MONITORING SYSTEM <br /> 54" CONTAINMENT COLLAR W/ A HYDROSTATIC 54 CONTAINMENT 5'-0" MIN. TO w <br /> I �, 0 Z Z <br /> 25 FLGD. MANWAY w/2 (4 ) NPT 36 SENSOR 7 -0 MAX. TOTAL BURY COLLAR W A 25 0 > <br /> FTGS. AND 2 (2") NPT FTGS. BRINE HYDROSTATICFLGD. MANWAY w/5 z <br /> RESERVOIR 33 33 (4") NPT FTGS. � m > > N D <br /> 0 <br /> IILf <br /> o <br /> o NOTE: m <br /> U�� �� m <br /> 1 . THE TANK FILL END SHALL BE N 0 <br /> o a <br /> ' ' ' ' INSTALLED ONE INCH LOWER IN o o Q o <br /> ELEVATION THAN THE TANK TURBINE <br /> END. <br /> IN-TANK GAUGE PROBE W/90% 2. CONTRACTOR SHALL VERIFY EXACT p <br /> OVERFILL ALARM CALIBRATION. INSTALL 47 48 51 o STRAP SPACING WITH TANK 4 :2 <br /> 2' DROP TUBE W/ OVERFILL PER MFR'S REQMNT'S. o MANUFACTURER PRIOR TO HOLD DOWN <br /> CLR. PREVENTION VALVE SET 15 <br /> 1 1 1 h ii i h i _ CONSTRUCTION. U) <br /> nP @ 95% CAPACITY. FE-PETRO CD I 3 <br /> TERMINATE DROP TUBE 40,000 GALLON DOUBLE WALL SUBMERSIBLE PUMP 38 24"x1 /4" THICK STRIKER o +' N <br /> CONTAINMENT SOLUTIONS II II II II II II II II PLATE UNDER ALL 3. BACKFILL TO MEET CLEAN FILL .� o I <br /> MIN. 4", MAX. 6 ABOVE REQUIREMENTS PER MANUFACTURERS cn <br /> STRIKER PLATE <br /> UNDERGROUND FIBERGLASS FE-PETRO INTAKE 40 OPENINGS BY TANK RECOMMENDATIONS. <br /> 4" TO 6" MAX. STORAGE TANK FILTER SCREEN MANUFACTURER (TYP.) LU E <br /> TANK BOTTOM4. GEOMEMBRANE TO BE INSTALLED PER <br /> a�5° (SEE CRITICAL DIM NOTE) 4) 0 O <br /> PROTECTOR(84 6' 1,f) <br /> MANUFACTURERS RECOMMENDATIONS (A Q ap N o <br /> AND BY CERTIFIED INSTALLER. J }+ 0-) N <br /> 39 38 37 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 2 1 — Q <br /> N NOTE: ACTUAL BENCH AND SLOPE #AN T <br /> LO 4Sro <br /> CONDITIONS TO BE EVALUATED BY m O N- <br /> 0111 <br /> c <br /> 10" 10' 10" 10" CONTRACTOR'S COMPETENT PERSON IN m V °0 Y `r' <br /> 16-1 2" <br /> / 1 -8 1 -8 1 -8 1 -8„ ACCORDANCE WITH ALL APPLICABLE SAFETY <br /> TYP. ORDINANCES AND CODES. WHERE BENCH <br /> 5'-6 1 /4” 8'-3" 5'-9 1 /2" 6'-10 1/2" 7'-2" 481 /2" 7'-2" 6'-10 1/2" 7'-2" 6'-10 1 /2" 5'-6 1 /4)) <br /> IS NOT CONSTRUCTED AS SHOWN DUE TO <br /> UNSTABLE SOIL CONDITIONS OR SAFETY " <br /> w <br /> 71 '-4" CONSIDERATIONS, SIDEWALL CLEARANCE TO N <br /> �► THE TANKS MUST BE INCREASED FROMCD <br /> Oil- t INDICATES STRAP PLACEMENT ® INDICATES HOLD DOWN STRAP CLIP ' INDICATES LIFTING LUG LOCATION INDICATES LIFTING LUG LOCATION 2'-0" TO 5'-0" PER MANUFACTURER'S <br /> A Gasoline 40,000 Gallon Tank Section NOTE: DROP TUBE CRITICAL DIMENSION: INSTALLATION INSTRUCTIONS. <br /> THE TANK FILL END SHALL BE INSTALLED 4" TO 6" MAX. (FROM TOP OF CUT TO TANK BOTTOM) THIS DIMENSION IS CRITICAL AND NOTE: CONTRACTOR SHALL VERIFY EXACT <br /> T3-1 SCALE: 3/8"=1 '-0" ONE INCH LOWER IN ELEVATION THAN THE MUST BE ADHERED T0. CONTRACTOR WILL BE REQUIRED TO REINSTALL AT OWN EXPENSE OR STRAP SPACING WITH TANK MANUFACTURER <br /> CD <br /> TANK TURBINE END. WILL BE BACK CHARGED FOR EXPENSE TO CORRECT INCONSISTENCIES. PRIOR TO HOLD DOWN CONSTRUCTION. Ln <br /> o <br /> 0 <br /> o L0 T o <br /> � o <br /> Z O t o <br /> . a <br /> o T i <br />