Laserfiche WebLink
Case Narrative C <br /> Client: Union Pacific RR Operations eProcurement Job ID: 440-248216-1 <br /> Project/Site: UPRR-Sludge Bin Stockton- New Profile <br /> Job ID: 440-248216-1 <br /> Laboratory: Eurofins TestAmerica, Irvine <br /> Narrative <br /> Job Narrative <br /> 440-248216-1 <br /> Comments <br /> No additional comments. <br /> Receipt <br /> The sample was received on 8/16/2019 2:09 PM; the sample arrived in good condition, properly preserved and,where required, on ice. <br /> The temperature of the cooler at receipt was 2.6°C. <br /> GC/MS VOA <br /> No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br /> GC/MS Semi VOA <br /> Method(s)8270C:The laboratory control sample and/or the laboratory control sample duplicate(LCS/LCSD)for preparation batch <br /> 440-564322 and analytical batch 440-564438 recovered outside control limits for the following analyte(s):4-Chloroaniline. This analyte <br /> has been identified as a poor performing analyte when analyzed using this method;therefore, re-extraction/re-analysis was not performed. <br /> The affected samples are reported with possible low bias for the failing analyte. <br /> Method(s)8270C:The laboratory control sample(LCS)for preparation batch 440-564322 and analytical batch 440-564438 recovered <br /> outside control limits for the following analytes: Benzo[a]pyrene. These analytes were biased high in the LCS and were not detected in the <br /> associated samples;therefore,the data have been reported. <br /> No additional analytical or quality issues were noted,other than those described above or in the Definitions/Glossary page. <br /> GC VOA <br /> No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br /> Metals <br /> Method(s)601013:The matrix spike/matrix spike duplicate(MS/MSD)recoveries of Antimony for preparation batch 440-565089 and <br /> analytical batch 440-565295 were outside control limits. Sample matrix interference and/or non-homogeneity are suspected because the <br /> associated laboratory control sample(LCS)recovery was within acceptance limits. <br /> No additional analytical or quality issues were noted,other than those described above or in the Definitions/Glossary page. <br /> Organic Prep <br /> No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br /> VOA Prep <br /> No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br /> Subcontract Work <br /> Method Fish Bioassay: This method was subcontracted to Aquatic Testing Laboratories. The subcontract laboratory certification is <br /> different from that of the facility issuing the final report. <br /> Eurofins TestAmerica Irvine <br /> Page 4 of 32 8/36/2019 <br />