Laserfiche WebLink
L <br /> J <br /> DIVISION 16 - GENERAL ELECTRICAL: smitty's <br /> STORAGE <br /> GENERAL Wings <br /> 1 . INSTALL ALL ELECTRICAL IN THIS WORK PER LATEST NEC AND CITY OF STOCKTON BUILDING DEPT. <br /> REQUIREMENTS. FLEXIBLE CONDUIT MAY BE USED BUT MUST CARRY GROUND WIRE TO BOX. 5654 N. PERSHING AVENUE <br /> SWITCH LIGHTING AS INDICATED ON DRAWINGS. ALL. CIRCUITS SHALL BE MARKED TO INDICATE STOCKTON, CA 95207 <br /> AREAS SERVED. PROVIDE ADDITIONAL CIRCUITS AS REQUIRED BY OTHER TRADES. GENERAL <br /> VV R /R WALK IN FREEZER ELECTRICAL MAYBE RUN IN FLEXIBLE METAL CONIDUIT, MC OR EMT, SETSCREW FITTINGS ON EMT. <br /> M R /R MC CABLE TO USED IN CONCEALED WALL OR CEIILING. INSTALL ALL FIXTURES PER MFG REQ. USE <br /> ONLY APPROVED AND LISTED EQUIPMENT. <br /> 2. CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE THWN/THHN. USE CONNECTORS APPROVED <br /> FOR RELATED WIRE SIZE. THE USE OF STRANDED OR SOLID APPROVED. USE STRANDED FOR SIZES <br /> �r #8 OR LARGER <br /> A B 3 ALL WORK SHALL CONFORM TO THE CEC 2016 EC)ITION AND TO THE APPLICABLE REQUIREMENTS <br /> KITCHEN AREA OF LOCAL, STATE, AND FEDERAL CODE(S) AND/OIR AGENCIES HAVING JURISDICTION, AND SHALL <br /> IT TAKE PRECEDENCE OVER WORK SHOWN. ANY DISCREPANCIES SHALL BE BROUGHT TO THE <br /> WH ATTENTIONQF THE DESIGNER PRIOR TO THE INSTALLATION OF VNORK, <br /> ANSUL 4, ELECTRICAL CONTRACTOR SHALL VFRII=Y DIAGRAMIMATIC LAYOUT OF ELECTRICAL WORK WITH <br /> OWNER PRIOR TO INSTALLATION. <br /> 5. SEE ELECTRICAL SYMBOLS, VERIFY ALL SYMBOLS AND CONDITIONS AS REQUIRED PRIOR TO <br /> ANSUL-2 � Ln <br /> INSTALLATION. <br /> JOB CONDITIONS <br /> ELECTRICAL DRAWINGS: THE ELECTRICAL DRAWINGS, AS CONTAINED, ARE ESSENTIALLY <br /> K �-� DIAGRAMMATIC AND ALTHOUGH THE SIZE AND LOCATION OF EQUIPMENT ARE SHOWN TO SCALE <br /> ANSUL-1 WHEREVER POSSIBLE CONTRACTOR SHALL MAKE USE OF ALL DATA AND VERIFY THIS INFORMATION <br /> AT THE BUILDING SITE. THE DATES INDICATED ONI THE DRAWINGS AND IN THE JOB CONDITIONS <br /> AND DECISIONS OF THE DESIGNER WILL GOVERN EXACT LOCATIONS, DISTANCES, LEVELS, AND <br /> OTHER CONDITIONS. <br /> z <br /> MA-1 > <br /> O 7. OPERATION : <br /> THE SYSTEM SHALL BE COMPLETE AND FULLY FUNCTIONING TO THE SATISFACTION OF THE <br /> DESIGNER AND THE OWNER. INSTALL ALL CIRCUITS, J-BOXFS, WIRING DISCONNECTS AND ANY <br /> OTHER EQUIPMENT NEEDED TO PROVIDE ELECTRICAL SERVICE FOR SIGNAGE. <br /> DUNG AREA <br /> 8. DRAWINGS: <br /> THE LAYOUT OF LIGHT FIXTURES ARE TO BE DIVIDED IN THE ROOM AS SHOWN ON THE PLANS. <br /> ANY Questions ABOUT LAYOUT SHOULD BE DIRECTED TO THE ENGINEER. UPON COMPLETION OF <br /> THE INSTALLATION, FURNISH A SET OF 'RECORD' (AS-BUILT) DRAWINGS TO THE DESIGNER <br /> CLEARLY MARKED WITH THE CHANGES AUTHORIZED DURING CONSTRUCTION, CUTTING NOTCHING <br /> DRILLING CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK HEREIN INCLUDING CUTTING, <br /> BORING, NOTCHING, FURRING AND DRILLING AS NECESSARY TO COMPLETE THIS PROJECT. "NOTE: <br /> NO CUTTING, BORING, NOTCHING, FURRING AND DRILLING OF TRUSS OR OTHER STRUCTURAL <br /> MEMBERS WILL BF ALLOWED, CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO ALLOW <br /> FOR GROUP RUNS AND ELIMINATE ANY OVERLAPPING OR OBSTRUCTION. <br /> 9. WORKING CLEARANCES <br /> WORKING CLEARANCE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT INCLUDING DISCONNECTS <br /> rC' <br /> -....._. <br /> WILL BE MAINTAINED AS PER CEC 2016 ARTICLE 110.26 c. cj 1"� ,-, F` .1 1- 1.7 <br /> f <br /> mer r' 1 ''. r. ,ustr'al <br /> /t <br /> lo. COMPLETION 0 F WORK AND TEST - David yL. da.- rsc�s , President w <br /> NORTH THE ENTIRE ELECTRICAL SYSTEM SHALL BE FREE FROM ANY SHORT CIRCUITS, AND IMPROPER DLJ 29 Davl-z�*. , X473883 <br /> 8839 Davi=�Road, Suite 8 <br /> W GROUNDS. DEMONSTRATE WITH THE OWNER AND DLSIGNER THAT THE ENTIRE INSTALLATION IS Stockton, CA 95208 <br /> 1/4" = V-Q" COMPLETE AND IN PROPER OPERATING CONDITION. (209) 473-2668 Fax 473-2671 <br /> Email: David*DIJElectric.com <br /> These drawings and specifications are the property and <br /> copyright of DLJ Electric and shall not be used or duplicated in <br /> part or in whole on any other work except by agreement with <br /> DLJ Electric. <br /> A B <br /> ROOM VOLTS 208Y/1 20V 3P 4W AIC 22,000 ROOM VOLTS 208 <br /> MOUNTING <br /> 3P �I-t`1 AIC 22.000 <br /> MOUNTING FLUSH BUS AMPS 200 MAIN BKR MLO MOUNTING FLUSH BUS AMPS 200 MAIN BKR MLO <br /> FED FROV UTILITY NEUTRAL 100% LUGS STANDARD FED FROM UTILITY NEUTRAL 100% BUGS STANDARD VAC JOB N0T H NOTE PANEL AND FEEDERS ARE EXISTING NOTE PANEL AND FEEDERS ARE EXISTING r 1 <br /> CKT CKT LOAD CKT CKT LOAD CKT CKT LOAD CKT CKT LOAD <br /> 1. ELECTRICAL PANEL �C RELATED FEEDERS ARE EXISTING BKR KVA CERCUIT DESCRIPTION BKR KVA CIRCUIT IJESCRIPTION BKR KVA CIRCUIT DESCRIPTION BKR KVA CIRCUIT DESCRIPTION POWER <br /> 1 20/1 1.2 LIGHTS a 2 20/1 1.5 TRACK LIGHTS 1 20/2 1.6 DOUGH ROLLER a 2 15/2 2.08 ICE MACHINE <br /> 2. INSTALL LLECTRICAL POWER TO HVAC UNITS KEF- 1 & MUA-1 3 20/1 X0.75 WALL SCONCES b 4 20/1 1.5 TRACK LIGHTS 3 1 b 4 I <br /> OF UNITS DURING 5 20/1 X1.1 SOFFET LIGHTS c 6 20/1 TRACK LIGHTS 5 20/3 1.4 EXHAUST FAN c 6 20/1 1.5 MAKE UP AIR <br /> 3. CONNECT UNITS TO EXIST{NG ANSUL SYSTEM WITH AUTOMATIC SEQUENCING PLAN <br /> 7 20/1 O 75 TV a 8 20/1 0 0-.72 RECEPTACLES 7 1 a 8 15/2 1.25 WALKIN COMPRESSOR <br /> ACTIVATION OF ANSUL SYSTEM 9 20/1 0.36 VIDEO GAMES b 10 20/1 0.72 RECEPTACLES 9 I b 10 I <br /> 11 20/1 0.36 VIDEO GAMES c 12 20/1 0.72 RECEPTACLES 11 20/1 0.18 RECEPT GFI ROOF c 12 20/1 1.2 AIRDOOR <br /> 4. INSTALL DISCONNECTS @ EACH UNIT <br /> I S WITHIN 25� oI UNITS 13 20/1 0.36 VIDEO GAMES a 14 20/1 1.3 SIGNAGE 13 20/1 1.6 LIGHTS a 14 20/1 0.18 RECEPTACLE NEXT TO DOUGH <br /> 5. CONFIRM GFI PROTECTED SERVICE OUTLET 15 20/1 0.36 VIDEO GAMES b 16 20/1 1.5 SHOW WINDOWS 15 20/1 0 SPACE b 16 20/1 1.5 WALKIN COOLER <br /> 17 20/1 ;0.86 RESTROOMs c 18 20/1 1.1 SALAD 17 20/1 o SPACE e 18 20/1 1.25 BEER DISPENSER <br /> 6, NO OTHER ELECTRICAL WORK IS BEING DONE WITHIN THIS SPACE <br /> 19 20/1 0 SPACE a 20 20/1 1.1 SODA 19 20/1 0 SPACE a 20 20/1 0 SPACE SUBMITTAL 02/27/19 <br /> 21 20/1 0 SPACE b 22 20/1 0.36 PREP TABLE 21 20/1 0 SPACE b 22 20/1 0 SPACE <br /> 7. UPDATE PANEL SCHEDULES 23 20/1 0 SPACE c 24 20/1 1.3 AIR DOOR 23 20/1 0 SPACE c 24 20/1 0 SPACE <br /> 25 20/1 0 SPACE a 26 20/1 1.5 DISHWASHER 25 20/1 0 SPACE a 26 50/3 14.4 ROHO-COUP <br /> 27 20/1 0 SPACE b 28 20/1 1.5 REFER FRONT COUNTER 27 20/1 0 SPACE b 28 I <br /> 29 20/1 0 SPACE c 30 20/1 1.5 REFER FRONT COUNTER 29 20/1 0 SPACE c 30 1 <br /> 31 20/1 0 SPACE a 32 20/1 1.2 POS FRONT COUNTER 31 20/1 0 SPACE a 32 40/3 10.8 A/C UNIT <br /> 33 20/1 0 SPACE b 34 20/1 0.6 POS FRONT COUNTER 33 20/1 0 SPACE b 34 1 <br /> 35 20/1 0 SPACE c 36 20/1 1.6 FREEZER 35 20/1 0.18 RECEPTACLE c 36 <br /> 37 20/1 O SPACE a 38 20/1 0.6 POS KITCHEN 37 40/3 10.8 A/C UNIT o 38 130/2 13.4 A/C UNIT <br /> HVAC SCHEDULE 3 30/2 3.1 PANEL ANSUL b 40 20/1 0 SPACE 3 I I b 40 I <br /> 411 I c 42 20/1 0 SPACE 411 I I c 42 20/1 0 SPARE <br /> CALLOUT SYMBOL VOLE'S AMT'S .SVA HP CIRCUIT <br /> CONN CALCI CONN CALL CONN CALCI CONN CALCI <br /> KVA KVA KVA KVA KVA KVA KVA KVA <br /> KEF-1 �- 120V 1 P 2W 9.8 1 .18 1/2 HP <br /> LIGHTING 9.35 11.7 (125%) RECEPTACLES 6.57 6.57 (50%>10) LIGHTING 1.6 2 (125%) KITCHEN 2.08 2.08 (100%) <br /> ST�� 1 HP LARGE (25%) KITCHEN 6.1 4.88 (8O%) LARGEST 14.4 3.6 (25%) EQUIPMENT <br /> MUA-1 120V 1 P 2W 1 6 MOTOR 1.92 0. <br /> EQUIPMENT MOTOR CONTINUOUS 2.75 3.44 (125%) <br /> MOTORS 4.4 4.4 (1 00 ) CONTINUOUS 1.7 2.13 (125%) MOTORS 21.4 21.4 (100%) HEATING 25 7.5 <br /> NONCONTINUOUS 2.9 2.9 (100%) RECEPTACLES 0.54 0.54 (50%>10) COOLING 25 0 (O%) E190 TOTAL LOAD 33 TOTALLOAD 58 <br /> BALANCED 3-PHASE BALANCED3-PHASE <br /> 161 <br /> AMPS 91.7 AMPS <br /> PHASE A 98.9% PHASE A 104% <br /> PHASE B 104% PHASE B 102% <br /> PHASE C 97.1% PHASE C 93.6% <br />