Data Qualifiers and Definitions <br />Qualifiers <br />A See Report Comments. <br />Analyte was present in an associated method blank. <br />B1 Analyte was present in a sample and associated method blank greater than MDL but less than DRL. <br />BQ1 No valid test replicates. Sample Toxicity is possible. Best result was reported. <br />BQ2 No valid test replicates. <br />BQ3 No valid test replicates. Final DO is less than 1.0 mg/L. Result may be greater. <br />Possible laboratory contamination. <br />RPD was not within control limits. The sample data was reported without further clarification. <br />D1 Lesser amount of sample was used due to insufficient amount of sample supplied. <br />D2 Reporting limit is elevated due to sample matrix. Target analyte was not detected above the elevated reporting <br />limit. <br />DW Sample result is calculated on a dry weigh basis. <br />Concentration is estimated because it exceeds the quantification limits of the method. <br />The sample was read outside of the method required incubation period. <br />Reported value is estimated <br />The laboratory control sample (LCS) or laboratory control sample duplicate (LCSD) was out of control limits. <br />Associated sample data was reported with qualifier. <br />The matrix spike (MS) or matrix spike duplicate (MSD) was not within control limits due to matrix interference. The <br />associated LCS and/or LCSD was within control limits and the sample data was reported without further <br />clarification. <br />M1 The matrix spike (MS) or matrix spike duplicate (MSD) is not within control limits due to matrix interference. <br />M2 The matrix spike (MS) or matrix spike duplicate (MSD) was not within control limits. The associated LCS and/or <br />LCSD was not within control limits. Sample result is estimated. <br />N1 Sample chromatography does not match the specified TPH standard pattern. <br />NC The analyte concentration in the sample exceeded the spike level by a factor of four or greater, spike recovery <br />and limits do not apply. <br />Sample was received without proper preservation according to EPA guidelines. <br />P1 Temperature of sample storage refrigerator was out of acceptance limits. <br />P2 The sample was preserved within 24 hours of collection in accordance with EPA 218.6. <br />01 Analyte Calibration Verification exceeds criteria. The result is estimated. <br />Q2 Analyte calibration was not verified and the result was estimated. <br />03 Analyte initial calibration was not available or exceeds criteria. The result was estimated. <br />04 Analyte result out of calibration range. Result was estimated. <br />The surrogate recovery was out of control limits due to matrix interference. The associated method blank <br />surrogate recovery was within control limits and the sample data was reported without further clarification. <br />S1 The associated surrogate recovery was out of control limits; result is estimated. <br />S2 The surrogate was diluted out due to the presence of high concentrations of target and/or non-target compounds. <br />Surrogate recoveries in the associated batch QC met recovery criteria. <br />Sample was extracted/analyzed past the holding time. <br />T1 Reanalysis was reported past hold time due to failing replicates in the original analysis (BOD only). <br />T2 Sample was analyzed ASAP but received and analyzed past the 15 minute holding time. <br />T3 Sample received and analyzed out of hold time per client's request. <br />T4 Sample was analyzed out of hold time per client's request. <br />T5 Reanalysis was reported past hold time. The original analysis was within hold time, but not reportable. <br />T6 Hold time is indeterminable due to unspecified sampling time. <br />T7 Sample was analyzed past hold time due to insufficient time remaining at time of receipt. <br />Definitions <br />DF Dilution Factor <br />MDL Method Detection Limit. Result is reported ND when it is less than or equal to MDL. <br />ND Analyte was not detected or was less than the detection limit. <br />NR Not Reported. See Report Comments. <br />RDL Reporting Detection Limit <br />TIC Tentatively Identified Compounds <br />Enthalpy <br />Analytical, Inc. <br />Analytical Results Report <br />56893-01 Lab Request 380652, Page 9 of 9