The primary filter bed, and ultimately the 100%replacement area filter bed will consist of Standard <br /> Infiltrator Chambers® SC (Shallow Cover). Six inch spacers must be used in-between the <br /> chambers. The pressure laterals will hang from the tops of the chambers with the effluent trickling <br /> down over the louvers. <br /> Backfill soil over the chambers must consist of a sandy loam material, with four to six inches of <br /> cover soil material over the chambers. A grass-type plant may be planted over the disposal area so <br /> that the plant roots can evapotranspire effluent from the louvers during favorable times of the year. <br /> Septic Tanks <br /> Influent from Mr. Rios' house will gravity flow into a 1,200 gallon, septic tank Effluent from this <br /> tank will level, or near-level gravity to the 2,000 gallon septic tank An Orenco Biofilter® will be <br /> installed in the be installed in the second compartment. Effluent from the Biofilter will be pumped <br /> to be equally distributed throughout the Infiltrator Chambers filter bed system. This 2,000 tank <br /> will provide preliminary treatment and trap paper, etc. The tank must be pumped on a prescribed <br /> interval basis depending on direct observations of paper and scum accumulation; e.g., every six <br /> months to every three years, depending on sludge/scum accumulation. <br /> Peaking factors for users on septic tanks vary with usage during the hour of the day, and day of the <br /> week. Peak hourly rates are associated with normal working hours. The ratio of the peak day to <br /> the average day can vary from 1.5 to >5, depending upon the usage. However,peaking factors are <br /> not as relevant since the effluent pump will dose on demand. A peaking factor of 2.5 (average <br /> between 0 and 5) will be used in the calculation below: <br /> Septic Tank Hydraulic Detention Time <br /> Detention Time= 1,200+2,000 izal septic tank capacity x 0.70(30%volume lost to sludge/scum accumulation) <br /> 2.5 (Peaking Factor)x 400 gals/day ADF <br /> Detention Time=2.2 days. The minimum acceptable detention time is 1.0 days. Therefore, a <br /> 1,200 gallon septic tank for the residential use and a 2,00 gallon tank for the winery is adequate. <br /> Primary and 100% Replacement Filter Bed Area <br /> The filter bed area is calculated in the procedure described in Section 8.7 of the San Joaquin <br /> County Sewage Standards and EHD Document 42-01-004: Calculation Requirements for Commercial <br /> Septic Systems: OP-4/1 <br /> Base Tank Capacity(BTC) = 1,200 gals / <br /> Lineal Feet of Leachline (LFLL) = 1,200 BTC +400 ADF x 0.225 Soil Factor based on a loam soil at <br /> 24 inches below grade where the soil-effluent interface will occur= 360 LFLL <br /> Filter Bed Area= 360 x 3 (Loam Soil Factor)= 1,080 square feet. The primary filter bed area is <br /> proposed to be rectangular in area: 25 ft wide x 43 ft long= 1,075 sq. ft. The manifold is to be at <br /> the northern end. QHS4ri.• All Y y <br /> Chesney Consulting <br />