Laserfiche WebLink
eIVEEDER ROOT Frr Pr Stainless Steel Mag Plus lnmTank Probe for Monitorin , Alternative <br /> �. FIF rev Fluids with No Water Detection in both USTs and ASTs <br /> Part # & Description Float Size Cable Min/Max <br /> Lengths Probe Length <br /> 846400-0X4 Mag Plus Alternative Fluids Float Kit - 4" (10 . 16cm) <br /> No Water Float <br /> Float Installation Kits 5' (1 . 5m), <br /> 846400 3X4 Mag Plus Alternative Fluids Float Kit 3" (762cm) 10' (3 . 05m), 48" (1 . <br /> . 2m) <br /> No Water Float 20' (6 . 1 m) 144" (3 . 66m) <br /> 846400-1 X4 Mag Plus Alternative Fluids Float Kit 2" (5. 08cm) <br /> No Water Float <br /> Other Installation Accessories 312020-952 4j' (1 Del 6cm) NPT Riser Cap and Ring Kit for In-Tank Probes <br /> 330020-282 4" (1Del 6cm) Threaded NPT Riser Cap for In-Tank Probes <br /> Specifications Product Water <br /> Measurement Accuracy +/- 0 . 0300" (0.762mm) N/A <br /> Resolution - One Sample Reading +/- 0. 002857" (0 . 072571 mm) N/A <br /> Minimum Measurement - 2" (5. 08cm) Float Kits 3 . 23" (8 .2cm) N/A <br /> Minimum Measurement - 3" (7. 62cm) Float Kits 3 . 04" (7 .72cm) N/A <br /> Minimum Measurement - 4" (10. 16cm) 3 . 04" (7.72cm) N/A <br /> Float Kits <br /> Operating (Working) Temperature Range -40 to +122• F (-40 to +500C) <br /> UL, cUL, ATEX, IECEx <br /> Third Party Evaluation / Agency Listings & Links <br /> http •//www. nwolde. org/evals/veeder root j . html <br /> Product Installation Guide Link https://www.yeeder. com/us/technical-documantALLary <br /> Example Installation <br /> 14 ' (35. 56cm) min. dia . manhole Probe cable Weatherproof junction box with 1 /2" (1 . 27cm) NPT <br /> threads (16 cubic inch (262.2cm3) minimum) <br /> Riser cap with cord grip Cord grip seals <br /> bushing and nut Neeeeee \ <br /> < . p r <br /> D . d D a <br /> Concrete slab or packed < P v <br /> earth per NFPA 80 Seal•off, epoxy seal per NFPA spec <br /> A 1 /2• (1 . 27cm) Rigid conduit (to Console) <br /> A = 10' (25.4cm) minimum for globalRiser pipe: 2- (5.08cm), 3- (7. 62cm), or 4" (10. 16cm) <br /> mag plus/mag plus probes. When �f API schedule 40 depending on probe type <br /> installing a probe longer than the the Note: Recommended distance between <br /> tank diameter, increase this minimum p probe and STP is at least 12" (30.48cm) <br /> dimension to compensate. / <br /> (Example: a 7' (2. 1m) - 6" (15. 24cm) Tank <br /> diameter tank will use an 8' (2.4m) _ Spiit•Ring Collar <br /> probe, in which case you must add 6 ' — — — — — (P/N 576008.617) TOP view <br /> (15, 24cm) to minimum riser length A). required if probe <br /> enters the riser. <br /> Mag Probe Side view 0 <br /> (rests on bottom) <br /> 878.13.eps <br /> www.veeder.com 125 Powder Forest Drive * PO Box 2003 Simsbury; CT 06070 a 02019 Veeder-Root & P/N 577014-449-08 Rev. A <br /> 1 68880561 o7942 All information contained in this document is subject to change without notice. <br />