My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
6232
>
3600 - Recreational Health Program
>
PR0360430
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2022 4:46:08 PM
Creation date
7/6/2022 4:44:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0360430
PE
3611
FACILITY_ID
FA0002351
FACILITY_NAME
PATMON ASHLEY PARK LP
STREET_NUMBER
6232
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09755002
CURRENT_STATUS
01
SITE_LOCATION
6232 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Facility Name and Address: PATMON ASHLEY PARK LP, 6232 N PERSHING AVE, STOCKTON 95207 <br />Swimming Pool Official Inspection Report <br /> #23 Pool Inlets and Outlets <br />OBSERVATIONS: One of the pool inlet cover is broken. Replace and maintain today. <br />CALCODE DESCRIPTION: Inlet fitting shall not protrude greater than 1 inch into the pool and shall be rounded and smooth. Wall inlets <br />shall be capable of adjusting the direction of flow. Each pool shall be provided with a main drain submerged suction outlet typically located <br />at the bottom of the pool. (CBC 3137B) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: The electrical breaker for the recirculating system sparks when turn on/off. Repair/replace today. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 30 <br />7.6 <br />3.6 <br /><30 Combined chlorine:ppm <br />NOTES <br />Routine inspection for pool. The followings were noted. <br />Influent: 5 psi. <br />Effluent: 10 psi. <br />The life-ring was on the floor/deck. <br />The rescue pole with the body hook was on the ground. <br />A loose rope was on the deck area. <br />Unable to test/verify the GFCI for the underwater pool light. <br />The breaker for the recirculating system sparks when turn on/off. <br />The inspection report was discussed with Samuel Diaz, pool operator, and Neil Royel, community director. <br />Inspection report will be email to Neil royel and Samuel Diaz. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: <br />EH Specialist:Phone:(209) 616-3051 <br />, <br />TOM HOANG <br />Page 2 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002351 PR0360430 SC001 07/05/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.