My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0002397
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MICKE GROVE
>
11793
>
2600 - Land Use Program
>
UP-90-05
>
SU0002397
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2022 4:17:52 PM
Creation date
7/7/2022 9:51:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0002397
PE
2626
FACILITY_NAME
UP-90-05
STREET_NUMBER
11793
STREET_NAME
MICKE GROVE
STREET_TYPE
RD
City
LODI
ENTERED_DATE
10/26/2001 12:00:00 AM
SITE_LOCATION
11793 MICKE GROVE RD
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
154
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 - <br /> SCREENED INTAKE, y <br /> SEE DETAIL ` ¢ <br /> BACKFILL <br /> �• �' �IDWA <br /> PORT, I <br /> 1 I <br /> MPE -1 <br /> I I <br /> 15# TARPAPER <br /> 8-4•'X12'X14'DEEP <br /> SUMP PITS. REFER f = <br /> DETAIL THIS SHEET. I 4" PERFORATED <br /> ' LEACH LINE <br /> I ! <br /> , R <br /> 8--4" PERFORATED LEACH <br /> LINES AT 12'-0 Q.C. LINES <br /> f <br /> l i <br /> SMALL BE INSTALLED WITH _-! r�-4- <br /> 11"-2-1/2"0 _ : I <br /> MAX. DEPTH OF 42". "- <br /> SEWER ROCK 6 1 I I <br /> � F <br /> GREASE INTERCEPTOR ^�/ f <br /> SEE DETAIL, SHEET MPE-2 / <br /> ♦ � I <br /> SUMP PIT DETAIL <br /> 3'X3'X12"D SCALE: NONE <br /> DIST. BOX ! 1! r _ 1 � FIRE LINE '"NOT IN f <br /> THIS CONTIRACT" I <br /> 4" 3'X3'X12"p DIST. LINE BURIED X30"FIDEEP f <br /> BOX WITH SLIDE <br /> DAMPERS <br /> 1 <br /> 2000 GAL. SEPTIC <br /> TANK #2. REFER , 1 ; - .-_ -r -j--._ � _ ,_ 1 F .I . _ - -� -._ • I <br /> DETAIL THIS SHEET 1 CLUBHOUSE I <br /> 4" 4" 4 1 <br /> ii <br /> " , <br /> 4* GCO GCOC _ <br /> ccs � <br /> - {} I <br /> ZABBEL FILTER r � <br /> FF <br /> SYSTEM OR 2000 GAL. SEPTIC <br /> APPROVED # <br /> TANK 1. REFER <br /> - _ CART BARN <br /> 3'X3'X12"D EQUAL DETAIL THIS Sl-IFFY �; � ' �... . t__.. ....- � � I --.._ � ----�------� � <br /> DIST. BOX <br /> T71' <br /> ` - <br /> t- i <br /> I <br /> #4 diameter bars <br /> 4-" X 3" 1/4" angios -_� ;' ---w_- . _ . _ - -- --- -- ' - W _- -- - .. . _. . . .. A . . _.._ . _ _ <br /> , <br /> - <br /> r j �-= L wr-... . _.__ . � _ —w- - <br /> _ _ <br /> - ----------_- _ -- -- -- 7 _ <br /> � __ <br /> .. <br /> a <br /> I I . <br /> �.. <br /> Y f <br /> FIRE DEPARTMENT <br /> - - _-t <br /> T <br /> -- { »- - I � CONNECTION <br /> .ter 2, C„ I 0.1 �. -6p) �, r •, �I I <br /> . 2 -0 _..- - - - -- - ....- - <br /> } <br /> --� OPENING -, I I , / 1 , _- .. ! ;'--- ._ � ;� � � � t: <br /> fi <br /> 0 iNG <br /> ..`---- —J 1 , \I I L�--i— •f - _ t- 1 ! � I I 1 ', r I I � I , , F <br /> r <br /> t� I I6" SCH 40 <br /> , <br /> 3 <br /> , <br /> , <br /> I <br /> �...-----------------J <br /> STEEL <br /> i <br /> PIPE-- <br /> I <br /> _- 6" DRY STANDPIPE WITH <br /> T 6•, <br /> / 2" FIRE DEPARTMENT _.-.. <br /> PLAN <br /> ,._ CONNECTION, FIELD <br /> �' LOCATE I 2'X2'X1' CONCRETE BLOCK <br /> f F { { I a+ 5" SCH 4 AROUND RISER <br /> PVC PIPE <br /> NOTES: - <br /> 1. Concrete shall b psi J ® 28 days. <br /> 'f <br /> I' <br /> 2. Ail relnforcJngiall be covered with not less than 1-1/Z" of con rete- <br /> RISER DETAIL <br /> Cast iron manhole cover , I I I I <br /> f I SCALE: <br /> I I I I — I <br /> Flush with finish rade <br /> g <br /> 1 Cleanout port <br /> F Josh Grade 1 I ----------- 4' <br /> : 6"SCH 40 PV __TC <br /> CONCRETE EXE_.. /' �affile on septic �ank /`- ! I I I I I I —_- T___ -.� I I PIPE <br /> „ r I. <br /> RING LENGHT AS ...-_ Number 2 only. } I I SCREEN OVER <br /> REQUIRED ( TWO I f <br /> REQUIRED) �- f . I �� � � I <br /> . � r I I END OF PIPE <br /> c a T, creep I I I f I 1 I -.1 ._.T t---�-. \. <br /> 9' 1--Q k °E J / 4 S.S. STRAPS, 1/2 <br /> - _- i 1 I 2-1"X1 4" S.S. " <br /> Screen � , ; i I I i � .�_..._-Wt._. -�_ ---.-- � - _+--T STRAPS WITH 1/2" <br /> 4" inlet .�3 \ WIDTH TO SECURE SCREEN <br /> 4 out et <br /> \ , 'S.S. BOLTS PER TO PIPE <br /> _ I STRAP <br /> MAINTENANCE DING - - TOP VIEW <br /> 4" E <br /> •II { I ; ;. T <br /> 4 0 <br /> 1 I I • I _ -�.... I <br /> 4 ® 8" oc I _ 1. <br /> I I I <br /> b <br /> both ways 6 0 f <br /> ' el• �I eJ ` \ � � � I <br /> _._...._._ . t lCa{ all WaiIS, I . I- •I• <br /> _............... _. L.. - <br /> top and bottom pja #- ...: GA5 METERS FURNISHED <br /> - & INSTALLED BY S.S. SCREEN WITH 18 HOLES <br /> OTHERS I : . PER SQ. IN. (50�; OPEN AREA) <br /> r I -----;_,r•�.�_1-_---__-• Jr - - MIN. ;3' <br /> d <br /> - ----- ---_ 6 <br /> POND <br /> BOTTOM OF PO <br /> ' v._1 <br /> 1 I GAS LINE FURNISHED I •�` <br /> C ACITY - 00 GALLONS\ 1 ' F.- . ._ . ._ F& INSTALLED BY MIN. I3' i i CONCRETE SUPPORT <br /> SEC N 'A—A' <br /> -_ / / 1 OTHERS I WITH #4 BARS B" <br /> ----.._. 1 `� o.c.e.w. <br /> f <br /> r f <br /> f <br /> i <br /> - = I SIDE VIEW <br /> it - <br /> __ END VIEW <br /> _- - - f i <br /> ---FDRREFED MEWR TO SHEET: PE <br /> SEPTIC- TAW-NAIL _ _ - _ r ` I <br /> SCALE. NONE �_-- <br /> -LL FIRE SYSTEM POND INTAKE DETAIL <br /> SCALE. NONE <br /> f eC <br /> R ^t <br /> : <br /> t <br /> n <br /> �� APR 3 V'n <br /> SITE PLAN - MECHANICAL / PLUMBING I �.� _. - -- „ E <br /> _ , ' ..P I . <br /> ti � e -> <br /> - <br /> _ -__ _- <br />
The URL can be used to link to this page
Your browser does not support the video tag.