ELECTRICAL SPECIFICATIONS <br /> 0 <br /> A. GENERAL REQUIREMEN <br /> lA <br /> 1. ELECTRICAL INSTALLATION SHALL COMPLY WITH TITLE 24, CALIFORNIA �. <br /> CODE OF REGULATIONS, INCLUDING THE FOLLOWING: CHRISTY N16 PULLBOX D' ,� 0 <br /> ` -- --�� <br /> TITLE 24, CCR, PART 2, 2007 CBCSEE ELECTRICAL SITET <br /> TITLE 24, CCR, PART 3, 2007 CEC P83 PLAN FOR CONTINUATION ��.. <br /> TITLE 24, CCR, PART 4, 2007 CMC <br /> TITLE 24, CCR, PART 9, 2007 CFC <br /> ALL APPLICABLE LOCAL CODES SEE ONE LINE PB4 <br /> DIAGRAM <br /> 2. ELECTRICAL CONTRACTOR SHALL VERIFY POWER, TELEPHONE AND CABLE TV ..-- <br /> SERVICES AT THE SITE PRIOR TO BIDDING. SERVICES TO CONFORM TO UTILITY COMPANY <br /> REQUIREMENTS. THE ELECTRICAL CONTRACTOR SHALL CONTACT THE UTILITY µ 0 "" 10 <br /> 0 �� <br /> COMPANIES IN A TIMELY FASHION TO ARRANGE FOR SERVICE INSTALLATIONOF <br /> ° __ �°` �` <br /> _r. <br /> PER UTILITY COMPANY REQUIREMENTS SO AS NOT TO DELAY THE INSTALLATION ���-- �" _m'm � �.� <br /> OF SERVICES AND PAY ALL CUSTOMER CHARGED SERVICE COSTS. _ "D o3. <br /> }� <br /> CONTRACTOR SHALL PROCURE AND PAY FOR ALL LICENSES, ETC. REQUIRED <br /> _W '-.. <br /> TO CARRY ON AND COMPLETE THE WORK. COUNTY TO PAY FOR PERMITS. — <br /> 4. PROVIDE ALL LABOR, MATERIALS, TOOLS, PLANT EQUIPMENT, <br /> AREA OF WORK <br /> TRANSPORTATION AND PERFORM ALL OPERATIONS NECESSARY FOR ANY REASONABLE "�-• ------ <br /> INCIDENTAL TO PROPER EXECUTION AND COMPLETION OF ALL "ELECTRICAL WORK" NORTH ! <br /> WHETHER SPECIFICALLY MENTIONED OR NOT; ALL AS INDICATED, SPECIFIED <br /> HEREIN, AND/OR IMPLIED THEREBY TO CARRY OUT THE APPARENT INTENT NORTH <br /> ENLARGEDTHEREOF. PUMP ELECTRICAL PLAN 5. ALL MATERIALS SHALL BE NEW AND LISTED WITH THE UNDERWRITERSSCALE I/16"={'-0" KEY PLAN <br /> LABORATORIES, INC., SHALL MEET THEIR REQUIREMENTS AND SHALL BEAR <br /> THEIR LABEL WHEREVER STANDARDS HAVE BEEN ESTABLISHED AND LABEL NTS <br /> SERVICE IS REGULARLY FURNISHED BY THAT AGENCY. <br /> 6. ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH X \ f <br /> THE SIZE AND LOCATIONS OF EQUIPMENT ARE SHOWN TO SCALE WHEREVER <br /> POSSIBLE, CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL CONTRACT -� <br /> DOCUMENTS AND VERIFY THIS INFORMATION AT THE SITE. CONTRACTOR SHALL EXISTING DISTRIBUTION <br /> BE RESPONSIBLE FOR LAYING OUT AND INSTALLING HIS WORK TO AVOID PANEL "A" <br /> INTERFERENCE WITH OTHER TRADES. . <br /> 8, __RACEWAYS & WIRING SYSTEMS <br /> 1. ALL LINE VOLTAGE WIRING SHALL BE INSTALLED IN RACEWAYS. RACEWAYS <br /> SHALL BE PVC TYPE DB-120 UNDERGROUND WITH PVC SCHEDULE 40 BENDS. <br /> CONDUIT STUB-UPS THROUGH SLAB SHALL BE PVC SCH. 40. LIQUID TIGHT <br /> FLEXIBLE CONDUIT FOR FINAL OUTDOOR CONNECTIONS. <br /> 2. CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE THHN/ EXISTING CONDUITSTHWN, �---� <br /> 600V, 90'/75' UNLESS OTHERWISE NOTED OR REQUIRED BY CODE. NEW CABLES SEE <br /> ONE LINE DIAGRAM f <br /> 3. WORK SHOWN ON THE DRAWINGS TO BE INSTALLED UNDERGROUND SHALL f <br /> BE INSTALLED AT LEAST 24" BELOW GRADE UNLESS OTHERWISE NOTED. BACKFILL EXISTING CONDUITS ,T <br /> IN 6" THICK, PROPERLY MOISTENED LAYERS, SOLIDLY PACKED AND IRON TAMPED " <br /> TO A DENSITY NOT LESS THAN THAT OF ADJACENT, UNDISTURBED EARTH. RESTORE NEW CABLES SEE <br /> SURFACES, ROADWAYS, WALKS, CURBS, WALLS AND EXISTING UNDERGROUND ONE LINE DIAGRAM P LLBOX <br /> INSTALLATIONS TO ORIGINAL CONDITION IN AN ACCEPTABLE MANNER. <br /> NAMEPLATES & IDENTIFICATION <br /> 1. INSTALL ENGRAVED NAMEPLATES FOR EACH PANELBOARD, CABINET, DISCONNECT, <br /> ETC. NAMEPLATES SHALL BE SECURELY FASTENED TO THE EQUIPMENT WITH #4 <br /> PHILLIPS ROUND HEAD CADMIUM PLATED SELF-TAPPING SCREWS. <br /> D. SUEPORTS <br /> 1. FURNISH ALL NECESSARY FOUNDATIONS, SUPPORTS, BACKING, ETC., FOR zoo B D G <br /> ALL ELECTRICAL ENCLOSURES, CONDUITS AND EQUIPMENT. <br /> 2. ATTACH ALL BOXES, CABINETS, ETC. TO WOOD WITH WOOD OR LAG SCREWS, <br /> TO METAL WITH MACHINE SCREWS OR BOLTS AND TO CONCRETE WITH EXPANSION f / EXISTING <br /> ANCHORS AND MACHINE SCREWS OR BOLTS. / <br /> / PULLBOX <br /> E. GROUNDING <br /> / P <br /> 1. GROUND AND BOND ALL EQUIPMENT AS REQUIRED BY GOVERNING CODES AND / <br /> SPECIFICALLY INCLUDING SWITCHBOARD, PANELBOARDS, TRANSFORMERS, MOTOR CASES, / <br /> ETC. <br /> SEE ONE LINE <br /> -. RV PEDESTAL DIAGRAM <br /> 1. PEDESTAL FOR SITE FOR LOT LIGHTS AND RECEPTACLES SHALL BE NEMA 3R, <br /> FREE STANDING, AS MANUFACTURED BY MILLBANK, TYPE U5200-XL--75 OR APPROVED 4w / <br /> EQUAL WITH DISTRIBUTION SECTION WITH BRANCH CIRCUIT BREAKERS AND INTEGRAL / <br /> RECEPTACLES AS SHOWN ON THE PLANS. ETC. FINISH TO BE STANDARD. ALARM HORN WITH / <br /> 2. SWITCHBOARD SHALL BE WEATHERPROOF, AS SPECIFIED ON THE SIGN NEXT TO <br /> / <br /> PLANS, FREE STANDING WITH LOCK PROVISIONS FOR LOCKING BY THE OWNER (e)PUMP PANEL LEACH / <br /> 3. UNIT SHALL BE MANUFACTURED FOR DIRECT BURIALFIELD .. AGROUND PULLBOX SCHEDULE. ALARM / <br /> 4. ALL BUSSING SHALL BE COPPER INCLUDING GROUND BUS. TAG PULL BOX TYPE <br /> � ���' ^_ / PB1 CHRISTY N16 <br /> 5. DISTRIBUTION SECTION SHALL BE OF CIRCUIT BREAKER TYPE UTILIZING -...�._� '�--// <br /> THERMAL MAGNETIC TYPE CIRCUIT BREAKERS WITH FRAME SIZES AS SHOWN ON P62 CHRISTY N16 <br /> / PB3 CHRISTY N16 <br /> SINGLE LINE DIAGRAM. � <br /> 6. ALL CIRCUIT BREAKERS SHALL BE IDENTIFIED WITH BAKELITE ENGRAVED /%i/ �zd� �, • <br /> PB4 CHRISTY N 16 <br /> NAMEPLATES. ca � � .- -� A�f'ACH!TO SIDE <br /> 7. SPACES FOR FUTURE CIRCUIT BREAKERS SHALL INCLUDE ALL HARDWARE, BUS "` -- ( BRIDGE. <br /> TAPS, ETC. NECESSARY TO PERMIT THE FIELD INSTALLATION OF BREAKER UNITS. '~ <br /> THE HARDWARE SHALL BE EQUIPPED WITH INSULATING TUBE OR BOOT. No,, s !H. PITS <br /> SITE LIGHTING 3�0� C0 ROL CABLE` <br /> .. FOR LEACH FIELD <br /> 1. PROVIDE POLE MOUNT, POST TOP SITE LIGHTING, COMPLETE WITH INTEGRAL 'S .ALARM SEE ONE <br /> PHOTOCELL CONTROLS AS SHOWN ON THE PLANS. LINE DIAGRAM. <br /> 2. MINIMUM CONDUIT FOR SITE LIGHTING SHALL BE 3/4" WITH MINIMUM WIRE SIZE TO - - P132i � C _ ---" <br /> BE #10, COPPER. P81 BEST F,0 - _ <br /> I. TESTING / <br /> r! �� <br /> 1. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE FREE FROM SHORT CIRCUITS <br /> AND IMPROPER GROUNDS. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND 6 B _ # 5KVA TRANSFbRME <br /> GROUNDS BEFORE ANY FIXTURES OR EQUIPMENT ARE CONNECTED AND WHETHER SUCH SEE ENLARGED PUMP i \ PAEL "P <br /> THIS SHEET " <br /> TESTS INDICATE FAULTY INSULATION OR OTHER DEFECTS, THEY SHALL BE LOCATED, ELECTRICAL PLAN -- <br /> REPAIRED AND RETESTED AT THE CONTRACTOR'S EXPENSE. ROTATION OF ALL MOTORS f t J \ / <br /> . - i j PUMP CONTRO <br /> SHALL BE CHECKED AND CORRECTED, IF NECESSARY, AFTER FINAL CONNECTIONS ARE ( i \\ PANEL CPL1 <br /> / <br /> MADE. 1 <br /> 2. DEMONSTRATE TO THE OWNER THAT THE ENTIRE INSTALLATION IS COMPLETE <br /> ' It ,/ •_` - 'e SEE ONE <br /> IN PROPER OPERATING CONDITION AND THAT THE CONTRACT HAS BEEN PROPERLY , / , LINE DIAGRAM \ _ � <br /> AND FULLY EXECUTED. PROVIDE ALL INSTRUMENTS TO MAKE SUCH TESTS. / ,� s \ e <br /> — / _.�..__.mol <br /> J. PULLBOXES __.._. ...� Y ,/ .� � �, r-' .,�4--�--" �' \ � <br /> 1. PROVIDE PULLBOXES WHERE SHOWN OR REQUIRED BY CODE. 1 I PB3d/ , i �" _ L <br /> 2. SIZE PULLBOX PER CODE. `"� I " <br /> • <br /> 3. 0 () 0 <br /> 00 <br /> PROVIDE FULL VEHICULAR RATED TRAFFIC COVERPLATE WHERE PULLBOXES <br /> ARE LOCATED IN AREAS WHICH COULD HAVE VEHICULAR TRAFFIC. - NORTH <br /> \ <br /> - �. , HCS ENGINEERING, INC. <br /> ELECTRICAL SITE PLAN_ <br /> E14W3 CONSULTING ELECTRICAL ENGINEERS <br /> p. 6--30-09 4512 FEATHER RIVER DRIVE SUITE '°F" <br /> SCALE I"=30-0" �'9r�FCTR►CP�� STOCKTON, CA 95219 (209)478-8270 <br /> tnpFCA1-�F� E—MAIL ADDRESS — BIIIOhcs--eng.com <br /> CA:000-227-2600 REVISION S <br /> PROJ.—_ 200$122--DES.. _ WDW—ENG.` IRKS -„ <br /> O NO. D E S C R I P T 1 0 N DATE I BY JOB NO. 07160 MICKE GROVE ZOO BACKWATER AND SEWAGE DISPOSAL SYSTEM SHEET <br /> ° BENCH MARK: . Civil Engineering <br /> CHISELED CROSS ON CONCRETE AT <br /> �....—... .................mew.......................Res......................, . Land <br /> Surveying DATE 05/23/08 <br /> WEST SIDE EXISTING AVIARY AS a Structural Engineering DESIGN WDW ELECTRICALESHOWN ON THIS PLAN. ELEVATION . Planning SITE PLAN <br /> 37.06 ' DRAWN WDW <br /> 4045 Coronado Avenue • Stockton, CA 95204 <br /> NV:800-227-2600 209 943-2021 • Fax: 209 942-0214 CHECKED RCS 11793 M I C K E GROVE ROAD OF 3 SHEETS <br /> E N G I N E E R I N G . INC. E—Mail: mailOslegfriedeng.com DRAWING FILE NO. <br /> F.B. NO. LODI , CALIFORNIA G <br />