Laserfiche WebLink
Environmental Health Department <br />Time In: <br />11:36 am <br />10:43 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: RAYMUS, ANTONE <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1830 E YOSEMITE AVE, MANTECA 95336 <br />Date: 06/28/2022Name of Facility: EL RANCHO MOBILEHOME PARK <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #12 pH Level MAJOR <br />OBSERVATIONS: pH is more than 8. Provide 7.2 - 7.8 today. Corrected on site. pH is 7.4 now. <br />CALCODE DESCRIPTION: Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #3 Safety Signs <br />OBSERVATIONS: Pool capacity and address signs are not available. Provide capacity and address signs today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Right side of the pool double hand rail and the pool single hand rail are loose. Secure hand rails in 1 <br />week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: Difference between the influent and the effluent readings is more than 10 PSI. Back wash filter today. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 40 <br />>8 <br />6.4 <br /><30 Combined chlorine:ppm <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001016 PR0360038 SC001 06/28/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD