Environmental Health Department <br />Facility Name and Address: BEST WESTERN EXECUTIVE INN & SUITES, 1415 E YOSEMITE AVE, MANTECA 95336 <br />Swimming Pool Official Inspection Report <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Single hand rail and both the double hand rails are loose. Secure all hand rails in 1 week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Both skimmers are lacking weir gates. Provide weir gates in 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #27 Pool Equipment Room <br />OBSERVATIONS: I observe a hole in the wall by the pool pump in the equipment room. Seal the hole in 3 weeks. <br />CALCODE DESCRIPTION: Pool operator shall keep ancillary facilities well maintained. (CCR 65535) All filters, valves, pumps, strainers <br />and equipment shall be readily accessible for repair and replacement. (CBC 3123B) <br /> #30 Pool Equipment and Plumbing Maintained <br />OBSERVATIONS: <br />CALCODE DESCRIPTION: All equipment related to pool operations shall be installed and maintained in accordance with manufacturer's <br />specifications and shall comply with applicable requirements established by applicable NSF/ANSI-50 performance standards. (CBC <br />3123B) <br /> #35 Flow Meters <br />OBSERVATIONS: Flow meter is stuck. Repair/ replace flow meter in 1 week. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />7.2 <br />1.4 <br />>100 Combined chlorine:ppm <br />NOTES <br />Page 2 of 3EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0000926 PR0360588 SC001 07/07/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD