My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 6:03:07 PM
Creation date
7/18/2022 8:43:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
UNFI GROCERS DISTRIBUTION, INC (STOCKTON)
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Overfill Prevention Equipment Inspection Report <br />B. OVERFILL PREVENTION EQUIPMENT DETAILS <br />Tank ID (one OPE per column) <br />Diesel <br />F1 Yes <br />® Yes <br />® Yes <br />M Yes <br />Are both vent and tank riser piping <br />secondarily contained? <br />® No <br />r] No <br />Ej No <br />® No <br />OPE Model C)-P'a <br />71SO <br />What is the OPE response when <br />El Shut off <br />Shut off <br />M Shut off <br />E] Shut off <br />activated? <br />Flow <br />Flow <br />Flow <br />Flow <br />(Check all that apply.) <br />® Restricts <br />MRestricts <br />® Restricts <br />[j Restricts <br />Flow <br />Flow <br />Flow <br />Flow <br />® Audible <br />El Audible <br />Fn Audible <br />M Audible <br />Alarm <br />Alarm <br />Alarm <br />Alarm <br />Visual <br />® Visual <br />® Visual <br />® Visual <br />Alarm <br />Alarm <br />Alarm <br />Alarm <br />Are flow restrictors installed on vent piping <br />Yes* <br />® Yes* <br />Yes* <br />® Yes* <br />that may interfere with the OPE operation? <br />F1 No <br />® No <br />® No <br />® No <br />At what level in the tank is the OPE set to <br />100.75 <br />activate? Inches from bottom of tank <br />What is the percent capacity of the tank at <br />93.5% <br />which the OPE activates? <br />Is the OPE in proper operating condition to <br />E] Yes <br />117 Yes* <br />® Yes* <br />® Yes* <br />respond when the stored substance <br />F No <br />rl No <br />rl No <br />® No <br />reaches the designated regulatory level? <br />7. SUMMARY OF TESTING RESULTS <br />Pass <br />El Pass ® Pass <br />® <br />Pass <br />OPE Inspection Results <br />Fail <br />Fail Fail <br />® <br />Fail <br />8. COMMENTS <br />Describe all answers marked "No" or "Fail" and proposed remedy. <br />List all monitoring equipment either replaced or repaired. <br />Inspection completed SR0085482 <br />* Mark here if: <br />® Flow restrictors interfere with overfill prevention and equipment repairs required. <br />Additional copies of this page may be attached. <br />Attach tank chart(s), measurements, calculations, and In -Tank Setup report(s) <br />Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.