Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:30 am <br />10:00 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 478-0175 Owner/Operator: GERA, MARKO <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 8600 N WEST LN, STOCKTON 95210 <br />Date: 07/26/2022Name of Facility: FRIENDLY VILLAGE MHP <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #1 Pool Gates MAJOR <br />OBSERVATIONS: Gate door near pool equipment room was not fully self-closing. Provide fully self-closing and self-latching <br />gate door. Corrected on site. <br />CALCODE DESCRIPTION: Gates and doors leading into the pool area shall be equipped with self-closing self-latching devices. <br />Self-latching devices shall be designed to keep the gate or door securely closed. Gates and doors shall open outward from the pool area <br />except where otherwise prohibited by law. (CBC 3119B) Pool operator shall keep gates and doors leading into the pool area well <br />maintained. (CCR 65535) <br /> #7 Pool Deck <br />OBSERVATIONS: Observed large gap in pool deck between concrete pads. Seal gap within 2 weeks. <br />Observed raised pool deck areas around coping. Resurface/shave pool deck so that it is free of tripping hazards. Correct <br />within 2 weeks. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Skimmer near ladder was lacking o-ring. Provide o-ring within 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 65 <br />7.8 <br />2.2 <br />35 Combined chlorine:ppm <br />NOTES <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002581 PR0360047 SC001 07/26/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD