Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
Environmental Health Department <br />Time In: <br />11:30 am <br />11:00 am <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: (209) 478-0175 Owner/Operator: GERA, MARKO <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 8600 N WEST LN, STOCKTON 95210 <br />Date: 07/26/2022Name of Facility: FRIENDLY VILLAGE MHP <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #3 Safety Signs <br />OBSERVATIONS: Both gate doors were lacking "Keep Gate Closed" signs. Provide signs today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #7 Pool Deck <br />OBSERVATIONS: Observed chairs within 4 ft of pool edge. Keep pool deck within 4 ft of pool edge unobstructed at all <br />times. Corrected on site. <br />Observed observed gaps and cracks in pool deck. Repair within 2 weeks. <br />Observed raised edges on pool deck near coping. Resurface/repair pool deck so that it is free of tripping hazards. Correct <br />within 2 weeks. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 70 <br />7.2 <br />3.6 <br /><30 Combined chlorine:ppm <br />NOTES <br />Routine inspection. <br />Back pool. <br />Influent: 16 PSI <br />Effluent: 15 PSI <br />Pool light and safety equipment ok. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002581 PR0360209 SC001 07/26/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD