Laserfiche WebLink
r I �,r Environmental Health Department <br /> SANJOAQUCUfT I� <br /> Greotness grows here Time In: 10.50 am <br /> Time Out: 11:46 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: ECONO LODGE Date: 07/27/2022 <br /> Address: 1625 E FRENCH CAMP TPKE, STOCKTON 95206 <br /> Owner/Operator: STOCKTON HOTEL GROUP LLC Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The hand rail on pool side is loose. Properly tighten and secure prior to resuming pool operations. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool.Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step.Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 311 1B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #35 Flow Meters <br /> OBSERVATIONS:The indicator on the flow meter is currently not functioning properly. Repair or replace to ensure flow <br /> meter is functioning and easily readable. Correct within 30 days. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 31256) <br /> #36 Pressure and Vacuum Gauges <br /> OBSERVATIONS:The effluent gauge is lacking on the filtration system. Obtain for the proper reading of effluent pressure. <br /> Correct by next routine inspection.. <br /> CALCODE DESCRIPTION:Pressure and vacuum gauges shall be provided for each pump system. (CBC 31256) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: 8.5 ppm Temp: ° F <br /> Cyanuric acid: 80 ppm pH: 7.2 Combined chlorine: .5 ppm <br /> NOTES <br /> FA0001722 PR0360086 SCO01 07/27/2022 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />