Laserfiche WebLink
r MJOA(1111 Environmental Health Department <br /> COUNTY I <br /> Gf$oLIS@SS 5rws hemTime In: 10.47 am <br /> Time Out: 11:09 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: COURTYARD VILLAGE Date: 08/08/2022 <br /> Address: 1690 TRACY BLVD,TRACY 95376 <br /> Owner/Operator: L&M PUTNAM DEVELOPMENT INC Telephone: (415)342-4220 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: INSPECTION/REINSPECTION (Chargeable) <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #2 Pool Enclosure <br /> OBSERVATIONS:Some of the bottom rails on the pool enclosure fence are rusty and loose(west side). Take action by <br /> next pool season to properly secure the loose rails. <br /> CALCODE DESCRIPTION:Pool area shall be enclosed by one or more of the following:a fence,portion of a building, wall, or other <br /> approved durable enclosure.Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br /> installed no more than 2 inches above the finished grade. Holes,gaps,or openings in the enclosure shall not allow the passage of a <br /> 4-inch diameter sphere.Doors, openable windows,or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br /> 31196) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br /> perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children.Horizontal members shall be spaced <br /> at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br /> arc. Chain link openings shall not be larger than 1314 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br /> are allowed if the enclosure was constructed prior to July 1994. (CBC 31196) <br /> #13 Cyanuric Acid Concentration <br /> OBSERVATIONS:The cyanuric acid level of the pool is greater than 100 ppm. Reduce the CYA level to less than 100 ppm <br /> by next pool season. <br /> A cyanuric acid reducer product may be used (use per label instructions).These may be found at pool supply locations. <br /> The cyanuric acid level may also be reduced by draining the pool, scrubbing the pool plaster, and refilling the pool with new <br /> water. <br /> CALCODE DESCRIPTION:Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: 6.0 ppm Temp: ° F <br /> Cyanuric acid: >100 ppm pH: 7.4 Combined chlorine: ppm <br /> NOTES <br /> FA0002959 PR0360402 SC333 08/08/2022 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />