My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2023 11:27:54 AM
Creation date
8/5/2022 10:02:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQU I N Environmental Health Department <br /> CDUNT '� <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> Manteca Valero (209)623-7676 August 16,2022 <br /> Facility Address: CERS ID: <br /> 1700 E YOSEMITE AVE, MANTECA, CA 95336 10181431 <br /> Inspection Contact: Title: Phone: <br /> Sunny Bhullar Owner (408)230-8999 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 -UST FACILITY <br /> Consent For: Consent GivenllaBy: <br /> O Inspection 0 Photos ElSamples Sunny Bhur,Owner <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Brian Roth 11/15/2023 Renee JD Arnaiz 11/24/2022 <br /> Service Technician Manufacturer's Training: <br /> VR,09/11/23;VMI, 10/21123;OPW, 10/21/23 <br /> CCR=Title 23 Oaliforom Code of Regulations HSC=Health and Safety Code CFR=Cade of Federal Regulatlana EHD=Environmental Health Department <br /> V=Violation R=Repeat violator, COS=Connected on site during inspection <br /> 101 HSC d) ! <br /> Failure to obtain a permit to operate from the EHO including but not limited to unpaid permit fees R V n R e COS <br /> 2711 <br /> 102 CCR 2711 failure to submit a complete and accurate application for a permit to operate a UST �V R COS <br /> 103 CCR 261 2636(,)(2) Failure to submit the UST Certification of Installation/Modification o V -i R COS <br /> 104 CCR 2(1 Failure to submit a complete and accurate UST Monitoring Plan o V a R o COS <br /> 2634d) <br /> 105 CCR 2632(d)(2), Failure to submit a complete and accurate UST Response Plan o V o R o COS <br /> 2634(e) <br /> 106 CCR 2632(4),2641(h) Failure to submit and maintain a current facility plot plan/site.map u V n R n COS <br /> 107 HSC 25291 CCR Failure to submit and maintain complete and current financial responsibility documents e V D R c COS <br /> 2711(a)(11) <br /> 108 1 CCR 2620(b);HSC Failure to implement or maintain a written agreement between the UST owner and operator o V n R u COS <br /> 25284(a)(3) <br /> 109 CCR 2715(a)(1)(5), Failure to submit"Designated Underground Storage Tank Operator Identification Form"within 30 days o V n R n COS <br /> 2715(a)(3) <br /> 110 CCR 2715(a)(1)(A), Failure to submit the"Underground Storage Tank Statement of Understanding and Compliance Fame" o V u R u COS <br /> 2715(a)(2) <br /> 111 CCR 2637.2638(a). Failed to notify the EHO 48 hours priorto conducting testing n V o R o COS <br /> 2643(g) <br /> 112 CCR 2638,26410), Failure to have properly qualified service technician test leak detection equipment every 12 months e V •R o COS <br /> 2715(fl <br /> 113 CCR 2637(a-d),2712(b) Failure to conduct secondary containment testing in V o R o COS <br /> (1)(F) <br /> 114 CCR 2636(()(3),2643(,) Failure to perform line integrity test every 12 months or within 30 days of repair of primary pipe n V o R o COS <br /> 3) <br /> 115 CCR 2638(,),2838(4) Failure to submit"Monitoring System Certification Form"within 30 days or completion of the test o V u R u COS <br /> 116 CCR 2537.1(d), Failure to:submit the"Spill Container Testing Report Form"within 30 days o V o R n COS <br /> 2637.1(a) <br /> 117 CCR 2637(e),2637(1) Failed to submit"Secondary Containment Testing Report Form"within 30 days after the lest u V u R u COS <br /> 118 CCR 2637.2(d&e), Failure to submit the"Overfill Prevention Equipment Inspection Report Form"within 30 days u V o R c COS <br /> 2665(8&b) <br /> 119 CCR 2663, 2712(b)(6) Failure to comply with tank lining certification,testing,inspection,and record requirements n V n R n COS <br /> 120 CCR 2631,2640.1, Failure tosubmit and/or maintain documentation regarding compatibility for UST system components ci V u R o COS <br /> 2665,2711 <br /> FA0003796 PRO231454 SC001 M1612022 <br /> EHD 23-01 Rev.1X06,2021 Page 1 of 5 Urch rground Storage Took Program OR <br /> 1868 E.Hazelton Avenue I Stockton,California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.crg/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.