Laserfiche WebLink
Environmental Health Department <br />Time In: <br />12:15 pm <br />11:40 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 478-6607 Owner/Operator: CEDAR CREEK PROPERTIES, LP <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 9430 WESTMORA CT, STOCKTON 95210 <br />Date: 08/09/2022Name of Facility: CEDAR CREEK PROPERTIES LP <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #12 pH Level MAJOR <br />OBSERVATIONS: The pH was 7.0. Maintain pool pH between 7.2-7.8 when operating. Corrected on site, it was 7.4. <br />CALCODE DESCRIPTION: Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: The shallow end hand rail was loose. Secure hand rail today. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #37 Electrical Hazards <br />OBSERVATIONS: Pump was not bonded/grounded. Corrected on site. <br />CALCODE DESCRIPTION: Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br />California Electrical Code. (CEC 680.4) Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br />fault circuit interrupter. (CBC 3160B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 70 <br />7.4 <br />9 <br />50 Combined chlorine:ppm <br />NOTES <br />Routine inspection. <br />Influent: 19 PSI <br />Pool light, safety equipment, and safety signs ok. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002900 PR0360327 SC001 08/09/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD