Laserfiche WebLink
RESTRICTED MATERIALS PERMIT#39-18-3900248 Page 8 of 9 <br /> LOMBARDI FARMS, J Expires: 12/31/2018 <br /> 3. Unless specifically named as a dust on this permit, NO DUST FORMULATIONS are allowed. <br /> 4.Apply pesticides covered by SLN(s)and Section 18(s) in conformance with the SLN(s)and Section 18(s), <br /> 5.A flagger is required at the application site for all AIR applications of Zinc Phosphide bait. <br /> Revised 10/90 <br /> Q Dicamba& Phenoxy Herbfclde CV <br /> CONDITION-Q-DICAMBA AND PHENOXY HERBICIDES-CENTRAL <br /> VALLEY/ <br /> In addition to all applicable laws, regulations and label restrictions,the CONDITIONS CHECKED BELOW APPLY to <br /> applications covered by this permit, <br /> [X] 1. No ester formulation applications allowed. <br /> [X] 2. Do not discharge material more than 10 feet above the crop or target. <br /> [X] 3.A drift reducing agent shall be added to the spray mixture at label rates. <br /> [X] 4. Maximum wind velocity for Phenoxy herbicides-10 m.p.h. <br /> [X] 5. Maximum wind velocity for Dicamba-10 m.p.h, EXCEPT when wind is moving in direction of sensitive crops,the <br /> maximum wind velocity-5 m.p.h. <br /> Revised 11/15 <br /> W Tree Hole-1,3-D and Chloropic <br /> CONDITION W Tree Hole Fumigation using 1,3-D and Chloropicrin <br /> In addition to labeling and California regulation requirements,these conditions apply in San Joaquin Co, <br /> A. For All Tree Hole Fumigations: <br /> 1. Notice of Intent: Required 48 hours before the start of the application. Waiver of the 48 hours must be requested and <br /> confirmed by the Commissioner before the start of the application. <br /> 2. Minimum buffer zone distance of 25 feet. <br /> 3. Certified Applicator Training <br /> Qualified Applicator Licensees(QAL)and Qualified Applicator Certificates(QAC)with subcategory"O"meet the labeled <br /> training requirement for Certified Applicators in charge of fumigations. If the QAC or QAL does not have subcategory"O"then <br /> training may be provided by the fumigant registrant(specific to active ingredient)and/or available online at <br /> www.epa.gov/fumiganttraining. Training must be renewed every 3 years and recorded on the Fumigation Management Plan <br /> priorto fumigant use. A Private Applicator Certificate does NOT meet this requirement and must complete the registrant <br /> training prior to fumigant use. <br /> 4. Fumigant Safe Handling Information <br /> Fumigant Safe Handling Information is required for all handlers involved in fumigation, in a manner that the handler can <br /> understand,and must be renewed every 12 months. Safe handling information includes: respiratory protection,signs and <br /> symptoms of exposure and emergency preparedness. The Certified Applicator must confirm handlers have received the <br /> Fumigant Safe Handling Information. Fumigant Safe Handling Information can be found where the fumigant product is <br /> purchased or at www2.epa.gov/soil-fumigants/safety-information-fumigant-handlers. <br /> 5. Fumigant Management Plan (FMP) <br /> A complete FMP must be available for review at the application site at the start of the fumigation. <br /> B. Chloropicrin 100% and in Combination with Other Products <br /> 1. Maximum number of tree holes and acreage allowed in a 24 hour period: <br /> Max. Holes/Ac Max.Ac <br /> 50 40 <br /> 75 10 <br /> 100 5 <br /> 200 1 <br />