My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MOUNTAIN HOUSE
>
19533
>
2300 - Underground Storage Tank Program
>
PR0547762
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 2:55:46 PM
Creation date
9/1/2022 9:00:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0547762
PE
2351
FACILITY_ID
FA0027204
FACILITY_NAME
SAFEWAY FUEL CENTER #0055
STREET_NUMBER
19533
Direction
S
STREET_NAME
MOUNTAIN HOUSE
STREET_TYPE
PKWY
City
MOUNTAIN HOUSE
Zip
95391
CURRENT_STATUS
01
SITE_LOCATION
19533 S MOUNTAIN HOUSE PKWY
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Received by EHD via email from <br /> Glenn Paredes on: Underground Storage Tank <br /> 9/27/2022 III Prevention Equipment Inspection Report <br /> 6. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (one OPE per column) Tank 1 87 Tank 2 91 Base Tank 3 DSL End <br /> Are both vent and tank riser piping [M Yes © Yes Q Yes © Yes <br /> secondarily contained? r] No 0 No r] No 0 No <br /> OPE Model 71 SO 71 SO 71 SO <br /> What is the OPE response when El Shut off El Shut off © Shut off C Shut off <br /> activated? Flow Flow Flow Flow <br /> (Check all that apply.) 17 Restricts ORestricts © Restricts 0 Restricts <br /> Flow Flow Flow Flow <br /> © Audible 0 Audible FM Audible [M Audible <br /> Alarm Alarm Alarm Alarm <br /> ® Visual © Visual © Visual Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping © Yes* Q Yes* Yes* Yes* <br /> that may interfere with the OPE operation? ® No ® No ® No r] No <br /> At what level in the tank is the OPE set to <br /> 105-5/8" 105-5/8" 106-3/4" <br /> activate? Inches from bottom of tank <br /> What is the percent capacity of the tank at 95% 95%o <br /> 95% <br /> which the OPE activates? <br /> Is the OPE in proper operating condition to ✓] Yes ✓❑ Yes* F1 Yes* 0 Yes* <br /> respond when the stored substance ❑F No 0 No © No 0 No <br /> reaches the designated regulatory level? <br /> 7. SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results ® Pass 0 Pass ❑fT Pass 0 Pass <br /> Q Fail © Fail © Fail El Fail <br /> 8. COMMENTS <br /> Describe all answers marked "No"or "Fail"and proposed remedy. <br /> List all monitoring equipment either replaced or repaired. <br /> * Mark here if: <br /> Flow restrictors interfere with overfill prevention and equipment repairs required. <br /> Additional copies of this page may be attached. <br /> Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.