Laserfiche WebLink
kn KLEIN FELDER <br /> 5.3 LEACHATE ASSESSMENT <br /> One slant boring will be drilled through the waste at the southeast comer of WMU B (as <br /> shown on Plate 5-1) to assess whether leachate exists at the soil/waste interface. If pooled <br /> leachate is encountered, the depth of leachate will be estimated. A leachate sample will be <br /> collected with a bailer or down-hole water sampling device and will be analyzed for the <br /> constituents listed on Table 5-2. If leachate is not encountered, a soil sample will be <br /> collected from immediately below the soil/waste interface and will be analyzed for the <br /> constituents in Table 5-1. The sampling plan is summarized in Table 5-3. Additionally, a <br /> waste sample will be collected and analyzed for percent saturation or moisture content. <br /> The soil sampling protocol is described in Appendix B. The analytical protocol is described <br /> in Appendix C. <br /> C7-90-99 11 <br />