My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2000-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
CORRESPONDENCE_2000-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2023 4:14:05 PM
Creation date
10/21/2022 10:00:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2000-2002
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
500
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM NO. 8 <br /> FORWARD INC. AND ALLIED INDUSTRIES <br /> FOR OPERATION OF <br /> FORWARD CLASS H LANDFILL <br /> SAN JOAQUIN COUNTY <br /> *Proposed new wells or new well pairs. <br /> Note that a suffix A was added to previous Austin Road well names to prevent <br /> confusion with old Forward wells. <br /> Hydrographs of each well shall be submitted showing the elevation of <br /> groundwater with respect to the elevations of the top and bottom of the screened <br /> interval and the elevation of the pump intake. Hydrographs of each well shall be <br /> prepared quarterly and submitted annually. <br /> Groundwater samples shall be collected from the point-of-compliance wells, <br /> evaluation wells,background wells, and any additional wells added as part of the <br /> approved groundwater monitoring system. Samples shall be collected and <br /> analyzed for the monitoring parameters in accordance with the methods and <br /> frequency specified in Table I. <br /> The monitoring parameters shall also be evaluated annually with regards to the <br /> cation/anion balance, and the results shall be graphically presented using a Stiff <br /> diagram, a Piper graph, or a Schueller plot. Samples for the constituents of <br /> concern specified in Table I shall be collected and analyzed in accordance with the <br /> methods listed in Table VI every five years. <br /> 2. Unsaturated Zone Monitoring <br /> The Discharger shall operate and maintain an unsaturated zone detection <br /> monitoring system that complies with the applicable provisions of§20415 and <br /> §20420 of Title 27 in accordance with a detection monitoring plan approved by <br /> the Executive Officer. The Discharger shall collect,preserve, and transport <br /> samples in accordance with the quality assurance/quality control standards <br /> contained in the approved Sample Collection and Analysis Plan. <br /> Unsaturated zone samples shall be collected from the monitoring devices (either <br /> suction lysimeters or pan lysimeters) and background monitoring devices of the <br /> approved unsaturated zone monitoring system. The collected samples shall be <br /> analyzed for the listed constituents in accordance with the methods and frequency <br /> specified in Table H. All monitoring parameters shall be graphed so as to show <br /> historical trends at each monitoring point. Samples for the constituents of concern <br /> specified in Table II shall be collected and analyzed in accordance with the <br /> methods listed in Table VI every five years. <br /> The pan lysimeters shall be checked monthly for liquid and monitoring shall also <br />
The URL can be used to link to this page
Your browser does not support the video tag.