Laserfiche WebLink
Environmental Health Department <br />Time In: <br />12:12 pm <br />11:30 am <br />Time Out: <br />Program Element: 1614 - FOOD EST>1001 SQ FT W/O SEATING <br />Telephone: (209) 235-5555 Owner/Operator: RATTANACHANE, OUDOM <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 520 E YOSEMITE AVE, MANTECA 95336 <br />Date: 10/19/2022Name of Facility: PIZZA GUYS <br />Food Program Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7; <br />113700. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and have the potential to cause foodborne illness. All major violations must be corrected immediately. Non-compliance may warrant immediate closure of <br />the food facility. <br /> #38 Approved / Sufficient Ventilation and Lighting <br />OBSERVATIONS: All light boxes at the washing area, at the food prep area, are lacking covers or shatterproof. Provide <br />shatterproof or boxes covers in 2 weeks. <br />CALCODE DESCRIPTION: Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors and smoke and be approved by <br />the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation <br />to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a <br />light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas <br />to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed <br />shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #41 Plumbing Maintained; Approved Back Flow Device <br />OBSERVATIONS: Rest room hand sink drains slowly. Fix drainage in 1 week. <br />CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device, as required <br />by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br />ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose <br />used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171, <br />114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> #43 Toilet Facilites Clean/ Supplied/ Maintained <br />OBSERVATIONS: Rest room self closing door is kept open during my inspection. Keep the rest room door closed at all <br />times. <br />CALCODE DESCRIPTION: Toilet facilities shall be maintained clean, sanitary and in good repair. Toilet rooms shall be separated by a <br />well-fitting self-closing door. Toilet tissue shall be provided in a permanently installed dispenser at each toilet. The number of toilet <br />facilities shall be in accordance with local building and plumbing ordinances. Toilet facilities shall be provided for patrons: in <br />establishments with more than 20,000 sq ft. establishments offering on-site liquor consumption. (114250, 114250.1, 114276) <br />Page 1 of 2EHD 16-23 Rev. 09/16/2020 Food Program OIR <br />FA0001289 PR0161519 SC001 10/19/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD