Laserfiche WebLink
MONITORING AND REPORTING PROGRAM ORDER NO. R5-2015-0012 6 <br /> HUMAN SERVICES AGENCY, 145 SOUTH SUTTER STREET, STOCKTON, CA 95202 <br /> IN-SITU REMEDIATION OF PETROLEUM HYDROCARBONS <br /> SAN JOAQUIN COUNTY <br /> Each quarterly report shall include the following minimum information: <br /> (a) a description and discussion of the groundwater sampling event and results, including <br /> trends in the concentrations of pollutants and groundwater elevations in the wells, how <br /> and when samples were collected, and whether the pollutant plume(s) is delineated; <br /> (b) field logs that contain, at a minimum, water quality parameters measured before, <br /> during, and after purging, method of purging, depth of water, volume of water purged, <br /> etc.; <br /> (c) groundwater contour maps for all groundwater zones, if applicable; <br /> (d) pollutant concentration maps for all groundwater zones, if applicable; <br /> (e) a table showing well construction details such as well number, groundwater zone being <br /> monitored, coordinates (longitude and latitude), ground surface elevation, reference <br /> elevation, elevation of screen, elevation of bentonite, elevation of filter pack, and elevation <br /> of well bottom; <br /> (f) a table showing historical lateral and vertical (if applicable) flow directions and gradients; <br /> (g) cumulative data tables containing the water quality analytical results and depth to <br /> groundwater; <br /> (h) a copy of the laboratory analytical data reports; <br /> (i) the status of any ongoing remediation, including an estimate of the cumulative mass of <br /> pollutant removed from the subsurface, system operating time, the effectiveness of the <br /> remediation system, and any field notes pertaining to the operation and maintenance of the <br /> system; and <br /> (j) if applicable, the reasons for and duration of all interruptions in the operation of any <br /> remediation system, and actions planned or taken to correct and prevent interruptions. <br /> An Annual Report shall be submitted to the Central Valley Water Board by 1 February (1 <br /> November for semi-annual monitoring) of each year. This report shall contain an evaluation <br /> of the effectiveness and progress of the investigation and remediation. The Annual Report may <br /> be substituted for the fourth quarter (or second semi-annual) monitoring report as long as it <br /> contains all of the information required for that report plus that required for the Annual Report. <br /> The Annual Report shall contain the following minimum information: <br /> (a) both tabular and graphical summaries of all data obtained during the year; <br /> (b) groundwater contour maps and pollutant concentration maps containing all data obtained <br /> during the previous year; <br />