My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MOUNTAIN HOUSE
>
19533
>
1600 - Food Program
>
PR0547980
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2023 12:53:22 PM
Creation date
11/1/2022 2:14:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547980
PE
1617
FACILITY_ID
FA0027360
FACILITY_NAME
SAFEWAY FUEL #5816
STREET_NUMBER
19533
Direction
S
STREET_NAME
MOUNTAIN HOUSE
STREET_TYPE
PKWY
City
MOUNTAIN HOUSE
Zip
95391
CURRENT_STATUS
01
SITE_LOCATION
19533 S MOUNTAIN HOUSE PKWY
P_LOCATION
99
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AIR BALANCE SCHEDULEEXHAUST CALCULATIONZONE IDENTIFICATIONEXHAUSTAIRFLOWREQUIRED(CFM)EXHAUSTRATE(CFM/UNIT)TOTAL (900 CFM OF OUTDOOR AVAILABLE FOR EXHAUST)RESTROOMS702019 CALIFORNIA MECHANICAL CODEWATERCLOSETS ORURINALS(QUANTITY)2EXHAUSTAIRFLOWPROVIDED(CFM)140220EXHAUSTRATE(CFM/SF)-AREA(SF)-140NOTE:EXHAUST RATES PER TABLE 403.7.AIR DEVICE SCHEDULEMARKDEVICE TYPEMAKEMODELMODULE SIZEMATERIALMAX NCLEVELPATTERNDAMPERALAY-IN SUPPLYTITUSMCD24"X24"STEEL25PLAQUE FACENONEBSURFACE SUPPLYTITUSMCD12"X12"STEEL25PLAQUE FACENONEDSURFACE SUPPLYTITUSCT-48024"X4"STEEL25BAR GRILLENONEESURFACE RETURN/EXHAUSTTITUS50FSEE PLANSTEEL25EGGCRATENONEGSURFACE EXHAUSTTITUS350RL12"X6"STEEL25ROUND DIFFUSERNONEMECHANICAL SYMBOLS LEGENDSINGLE LINEDUCTWORKDOUBLE LINEDUCTWORKDESCRIPTIONRECTANGULAR AND ROUND DUCT. DUCT SIZES AREIN INCHES. DUCT SIZES REPRESENT INSIDEDIMENSIONS OF DUCTWORK.45° TAP USED AT BRANCH DUCTS ONLY.CONICAL TAP USED AT ROUND BRANCH DUCTS.90° ELBOW WITH SINGLE RADIUS TURNING VANESCURVED ELBOW (MIN. RADIUS R = 1.5 WIDTH)FLEXIBLE DUCT CONNECTIONSPIN-IN FLEX DUCT TAKE-OFF WITH MANUALBALANCE DAMPER. FLEX DUCT NOT TO EXCEED 6'-0"BALANCING DAMPER (USE ODB UNLESS OTHERWISENOTED)SMOKE DAMPER, FIRE DAMPER, AND COMBINATIONFIRE SMOKE DAMPER WITH ACCESS PANEL.DUCT SMOKE DETECTOR.DUCTWORK DOWN.DUCTWORK UP.RECTANGLE TO ROUND TRANSITION.PROGRAMMABLE THERMOSTAT, THERMOSTATLOCKING GUARD, TEMPERATURE SENSOR,HUMIDSTAT & CO2 SENSORPOINT OF CONNECTION.EXISTING TO REMAIN.EXISTING TO BE DEMOLISHED.GRILLES REGISTERS AND DIFFUSERS.WXDWXDW"ØW"ØWXDWXDWXDWXDWXDX"Ø <br />EQUIPMENTEQUIPMENTWXDROUND DUCTWORK.WXDWXDX"ØX"Ø*** ALL SYMBOLS ON LEGEND MAY NOT APPLY TO DRAWING(S). ***SUPPLYRETURNEXHAUSTROUNDSIDEWALLLINEARACCESS PANEL.MOTORIZED DAMPER.SUPPLYRETURNEXHAUSTSUPPLYRETURNEXHAUSTSUPPLYRETURNEXHAUSTSUPPLYRETURNEXHAUSTUPDOWNUPDOWNFDFDFSDEXHAUST FAN SCHEDULEPACKAGED SPLIT SYSTEM SCHEDULENOTES: 1.PROVIDE WITH SECONDARY DRAIN PAN.2.SUSPEND FROM STRUCTURE WITH 3/8" THREADED RODS WITH VIBRATION ISOLATORS.3.PROVIDE WITH CONDENSATE BASIN AND EXTERNAL PUMP WHERE SLOPE IS INSUFFICIENT TO ROUTE TO NEAREST APPROVED RECEPTOR.4.OUTSIDE AMBIENT TEMPERATURES: (SUMMER = 100° F DB: 70° F WB) (WINTER = 31° F.)5.NO EQUIPMENT WITH LESS THAN 98 % OF LISTED CAPACITIES OR FACE AREA WILL BE APPROVED. COOLING COIL CAPACITY INCLUDES FAN MOTOR HEAT. MAXIMUM FACE VELOCITY = 500 FPM. MAXIMUM FIN SPACING = 12 FPI.6.ACTUAL FAN BHP AT DESIGN CFM AND STATIC PRESSURE MUST NOT EXCEED 102% OF LISTED BHP.7.MOTOR HP AT 1.0 SERVICE FACTOR MUST BE A MINIMUM OF 10% GREATER THAN ACTUAL FAN MOTOR BHP.8.UNIT SHALL HAVE LOW AMBIENT COMPRESSOR LOCK-OUT THERMOSTAT.9.EXTERNAL STATIC PRESSURE SHALL INCLUDE DUCT AND DUCT-MOUNTED COMPONENTS SHOWN ON DRAWINGS ONLY. VENDOR= SHALL CALCULATE INTERNAL STATIC PRESSURE FOR SUCH ACCESSORIES AS FILTERS, DAMPERS, HEAT EXCHANGERS OR COILS, DOWNFLOW OR DISCHARGE/PLEMUMS, ETC., WHEN SPECIFIEDAS PART OF UNIT.10.FILTER ATMOSPHERIC EFFICIENCY (500 FPM MAXIMUM VELOCITY) = 30%. FILTER DEPTH = 2"11.PROVIDE UNITS WITH FILTER HOUSING, GASKETED PANELS, (ODP) MOTOR, ENCLOSED BELT GUARD WITH TACH OPENING, PAINTED CASING FINISH FOR ADDITIONAL REQUIREMENTS.12.SEE MANUFACTURER'S WRITTEN SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.CSPIRAL DUCT SUPPLYTITUSS300FS12"X4"STEEL25LOUVEREDNONEVENTILATION CALCULATIONZONE IDENTIFICATIONOCCUPANCY CATEGORYAREA(SF)PEOPLEOUTDOOR RATE(CFM/PERSON)AREA OUTDOORAIR RATE(CFM/SF)OCCUPANTDENSITY(#/1000 SF)BREATHINGZONE OUTDOORAIR FLOWVBZ/(CFM)TABLE 6-2ZONE AIRDISTRIBUTIONEFFECTIVENESSZONE OUTDOORAIR FLOWVOZ/(CFM)TABLE 6-3SYSTEMVENTILATIONEFFICIENCYOUTDOOR AIRINTAKE FLOWVOT/(CFM)OUTDOOR AIRINTAKE FLOW(CFM)ZONE PRIMARYAIR FLOWFRACTIONVPZ/(CFM)PRIMARYOUTDOOR AIRFLOW FRACTIONZP=VOZ/VPZ2019 California Mechanical CodeRETAILSALES802157.5.12186.5.80233.1TOTALFC-1233.11.00233.12331600.15VENTILATION CALCULATIONZONE IDENTIFICATIONOCCUPANCY CATEGORYAREA(SF)PEOPLEOUTDOOR RATE(CFM/PERSON)AREA OUTDOORAIR RATE(CFM/SF)OCCUPANTDENSITY(#/1000 SF)BREATHINGZONE OUTDOORAIR FLOWVBZ/(CFM)TABLE 6-2ZONE AIRDISTRIBUTIONEFFECTIVENESSZONE OUTDOORAIR FLOWVOZ/(CFM)TABLE 6-3SYSTEMVENTILATIONEFFICIENCYOUTDOOR AIRINTAKE FLOWVOT/(CFM)OUTDOOR AIRINTAKE FLOW(CFM)ZONE PRIMARYAIR FLOWFRACTIONVPZ/(CFM)PRIMARYOUTDOOR AIRFLOW FRACTIONZP=VOZ/VPZ2019 California Mechanical CodePREP AREAMEAT PROCESSING4031015.0.0060.5.8075.6RETAILSALES552157.5.12128.3.80160.4TOTALFC-2236.01.00236.02361600.15VENTILATION CALCULATIONZONE IDENTIFICATIONOCCUPANCY CATEGORYAREA(SF)PEOPLEOUTDOOR RATE(CFM/PERSON)AREA OUTDOORAIR RATE(CFM/SF)OCCUPANTDENSITY(#/1000 SF)BREATHINGZONE OUTDOORAIR FLOWVBZ/(CFM)TABLE 6-2ZONE AIRDISTRIBUTIONEFFECTIVENESSZONE OUTDOORAIR FLOWVOZ/(CFM)TABLE 6-3SYSTEMVENTILATIONEFFICIENCYOUTDOOR AIRINTAKE FLOWVOT/(CFM)OUTDOOR AIRINTAKE FLOW(CFM)ZONE PRIMARYAIR FLOWFRACTIONVPZ/(CFM)PRIMARYOUTDOOR AIRFLOW FRACTIONZP=VOZ/VPZ2019 California Mechanical CodeRETAILSALES552157.5.12128.3.80160.4PREP AREAMEAT PROCESSING2821015.0.0042.3.8052.9TOTALFC-3213.31.00213.32131600.13FLAY-IN RETURN/EXHAUSTTITUS50F24"X24"STEEL25EGGCRATENONENOTESA.DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL ARRANGEMENT OF EQUIPMENT AND SYSTEMS.THEY ARE NOT INTENDED TO SHOW EVERY OFFSET, FITTING, AND COMPONENT. DO NOT USE THE PLANS FOREXACT LOCATION OF EQUIPMENT, FIXTURES, OR ARCHITECTURAL ITEMS SUCH AS WALLS, WINDOWS, SOFFITS,ETC. SPECIFIC LOCATIONS, MOUNTING HEIGHTS, AND OVERALL DIMENSIONS OF DEVICES AND FIXTURESSHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS AND DETAILS WHEN AVAILABLE.B.DRAWINGS SPECIFIC TO THIS TRADE DO NOT LIMIT THE RESPONSIBILITY OR WORK REQUIRED BY THECONTRACT DOCUMENTS. REFER TO DRAWINGS AND SPECIFICATION OF OTHER TRADES FOR COMPLETEINFORMATION PRIOR TO BID.C.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS, LABOR, PERMITS, INSPECTIONS, FEES, QUALITYOF MATERIALS AND WORKMANSHIP, AND FINAL CLEAN-UP PERTAINING TO THEIR WORK.REGISTERS, GRILLES AND DIFFUSERS. DUCT REGISTERS, GRILLES AND DIFFUSERS SHALL BE INSTALLED INACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTIONS. VOLUME DAMPERS OR OTHERMEANS OF SUPPLY AIR ADJUSTMENT SHALL BE PROVIDED IN THE BRANCH DUCTS OR AT EACH INDIVIDUAL DUCTREGISTER, GRILLE OR DIFFUSER. EACH VOLUME DAMPER OR OTHER MEANS OF SUPPLY AIR ADJUSTMENT USEDIN BALANCING SHALL BE PROVIDED WITH ACCESS.ENERGY COMPLIANCE NOTESAIR BALANCE AIRFLOW DIAGRAMAIR CURTAIN SCHEDULEM1.0MECHANICALSCHEDULES--www.stantec.com <br />TEL. <br />1383 North McDowell Blvd. Suite 250 <br />Petaluma, CA 94954 <br />707.765.1660 <br />Architecture Inc.RENGINEERING, INCOBISON19401 40TH AVE W., SUITE 302LYNNWOOD, WA 98036206-364-3343 telCONTACT: MARK MANGLICMOT5/14/21-
The URL can be used to link to this page
Your browser does not support the video tag.