My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
134
>
1600 - Food Program
>
PR0547891
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:13:58 PM
Creation date
11/1/2022 2:41:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547891
PE
1624
FACILITY_ID
FA0027299
FACILITY_NAME
PHO RICE & ROLL'D
STREET_NUMBER
134
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
134 W YOSEMITE AVE
P_LOCATION
04
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLU E FAN COIL <br /> ROLL FLASHING OVER TOP <br /> THERMOMETERI EDGE FOR VENTS 3" AND COUNTER FLASHING AND SLOPE PIPING AS MUCH PROVIDE CLEANOUTS <br /> l � I GREATER. ALLOW CLEARANCE SEALANT FOR VENTS 2\" <br /> T CW FOR EXPANSION. AND SMALLER AS POSSIBLE TOWARD IN TURNS/ENDS OF VSAC DESIGN <br /> UNION TYP. I \ ) DISCHARGE, TYPICAL PIPE, TYPICAL <br /> P❑ Box 163686 <br /> U �, -HW 9» MIN Sacrarento, CA 95816 <br /> �. EXPANSION TANK INDIRECT WASTE CONDENSATE Tel,: 916,752,2022 <br /> LEAD FLASHING, TYPICAL LAP ROOFING OVER FLASHING PIPING PIPING PROVIDE VENTED <br /> FILL VOID WITH INSULATION WITH ROOFING SEALANT P—TRAP AT FAN <br /> PTRV "WATTS" 40XL RUN HARD FIN. FLOOR MIN 2" COIL, TYPICAL <br /> # MATERIAL, TYPICAL BUILT—UP ROOFING The use of these drawings and <br /> TEMPER COPPER DISCHARGE TO °° . ° ° ° ' ° .° o , specifications shall be restricted to <br /> G MOP SINK ° ° ROUTE PIPING INCONSPICUOUSLY the specific site for which they were <br /> '"' <br /> ° ° °' o o: prepared and publication thereof <br /> AND UNOBTRUSIVELY. HANG PIPE shall be expressly limited to such <br /> SECURE WATER HEATER TO WALL AS REQUIRED. DO NOT INSULATE usel Rei use, reproduction or <br /> publication by any method in whole <br /> FLOOR SINK INDIRECT DRAIN PIPE WHEN EX— or part is prohibited. Title to these <br /> WITH (2) 16 GA.x 2" WIDE STEEL STRAPS. POSED IN FOOD SERVICE FACILITYplans and specifications Shall remain <br /> GAS PIPING .SECURE STRAPS TO WALL WITH 3/8"� with VSAC Design without prejudice, <br /> ROOF STRUCTURE 2"I� MIN. and visual contact with them shall BOLTS THRU BLOCKING OR STUDS. constitute prima facie evidence of <br /> acceptance of these restrictions. <br /> © VSAC Design <br /> SHUT—OFF VALVE "P" TRAP <br /> 6" LONG DIRT LEG <br /> REVISIONS By <br /> WATER HEATER VENT THRU ROOF DETAIL 2 INDIRECT TO FLOOR SINK 3 <br /> SCALE: NONE SCALE: NONE SCALE: NONE <br /> FRAMED WALL <br /> 1/2" GV <br /> GAS PIPING EXPOSED ALONG BACK WALL BEHIND KITCHEN EQUIPMENT. <br /> TRAP PRIMER IN WALL <br /> BOX. SECURE TO SHUTOFFVALVE-TYPICAL, 0 <br /> FLUE cAI= <br /> WALL FRAMING ®° <br /> DRIP LEG-TYPICAL.TYPE '5" "LOCKABLE" ACCESS CONNECT TO CW <br /> OR EQUAL PANEL PIPE IN WALL SWIVEL 360°ROTATION FITTING. \\ <br /> COUNTER FLASHING \\ I \\ <br /> ----21-011 MIN. UNION � <br /> GAS PRESSURE REGULATOR- <br /> 1=LASHIhI3 - SEE TYPICAL. <br /> SFEGIFICATI©NS FIN. ROOF 1/2" CWD PROVIDE BLOCKING BEHIND <br /> FLOOR DRAIN W/TRAP WALLTO SECURE- ®Q„� ®q� q ®® <br /> PRIMER CONNECTION UJ�® 9 ®� 0 <br /> ate <br /> FIN FLOOR RESTRAINING CABLE-TYPICAL. 7 > <br /> MAINTAIN 2" MIN. <br /> HOSE GAS CONNECTOR,HEAVY DUTY, <br /> GEAR AL L AROUND a s a I I FLEXIBLE,CORRUGATED TYPE 304 <br /> a s a I I a d STAINLESS STEEL TUBING WITH STAINLESS O V <br /> O cin ° 4a d I ° L STEEL BRAID AND ANTIMICROBIAL PVC <br /> 4" FLUEa COATING-TYPICAL. <br /> -- 2" WIDE X 20 GA.GALV. <br /> 5HEE7 METAL SECURELY ® TYPICAL GAS FIRED KITCHEN U <br /> CL.AMFED TO FLUE: AMC) " SAFETY-SET POSITIONING SYSTEM EQUIPMENT. Q W <br /> OVERHEAD CONSTRUCTION. 1/2 BELOW FLOOR UNDER EACH CASTER-TYPICAL. � ♦^ <br /> HARD—DRAWN COPPER �JJ UJ <br /> INSTALLED W/ CONTINUOUS SLOPE O <br /> Q � z <br /> 1/2" CW TO TRAP Q <br /> FLUE VENT DETAIL CONNECT AS REQ'D GAS EQUIPMENT CONNECTION UJ 3 <br /> SCALE: NONE <br /> 4 SCALE: NONE <br /> TRAP PRIMER TO FLOOR DRAIN <br /> SCALE: NONE <br /> SAWCUT (E) CONC SLAB TO INSTALL PIPE <br /> POUR (N) CONCRETE SLAB EXISTING CONCRETE FLOOR SLAB <br /> TO MATCH (E) SLAB THICKNESS TO REMAIN IN PLACE (TYP) <br /> Drawing <br /> d <br /> PLUMBING DETAILS <br /> r <br /> SUBBASE TO MATCH EXISTWG---" z <br /> Uz <br /> a- w <br /> IMPORTED SAND OR o <br /> APPROVED CLEAN GRANULAR U J <br /> 85% COMPACTION U <br /> 0 <br /> ;• QRpFESS/pti <br /> NtA D. <br /> w = m = <br /> NO. C 60696 <br /> EXP. 12/31/22 Q <br /> �F CM-\F <br /> D <br /> D+16 Proj. No. <br /> Drawn HDV <br /> Date 7/20/2021 0 <br /> Q <br /> PLUMBING TRENCH Scale <br /> 7 Sheet <br /> SCALE: NONE P - 2 <br /> Sheet No. of Total Sheets <br />
The URL can be used to link to this page
Your browser does not support the video tag.