Laserfiche WebLink
1.G.C.TO ALWAYS FOLLOW THE MANUFACTURER'S INSTRUCTIONS THAT COME WITH THEHARDWARE.2.NOT EVERY INSTALLATION METHOD CAN BE DOCUMENTED. G.C IS EXPECTED TO KNOW HOW TOATTACH TO ANY TYPE OF CEILING STRUCTURE. THESE INSTRUCTIONS WILL ASSUME THAT G.C ISATTACHING UNISTRUT TO THE STRUCTURE ABOVE THE CEILING. PLEASE REFER TO DETAILS 1/A7.2& 2/A7.2 FOR MORE DETAILS.3.THE SCREENS SHOULD BE CENTRED 6‐24” BEHIND THE BACK EDGE OF THE PIZZA AND HOT DOGWARMING STATION AND NOT INTERFERE WITH THE SECURITY CAMERAS. THE SCREENS ENDUP 6” IN FRONT OF THE POLE, SO PLACE THE POLE 12‐30” BEHIND THE BACK EDGE OF THECOUNTER. CAMERAS ARE 360° AND LOOK AT THE CUSTOMER, CASH DRAWER AND CIGARETTERACK.4.TRIPLE SCREEN MOUNT - HARDWARE4.1.SCREEN MOUNT ‐ CHIEF LCM3X1U4.2.UNISTRUT ADAPTOR CHIEF CMA3724.3.COLUMN - CHIEF CPA0724.4.COLUMN TO UNISTRUT CONNECTOR - CHIEF CPA262GENERAL NOTESTRIPLE MENU BOARD - CEILING MOUNT:5.TRIPLE MENUBOARD MOUNT - INSTALLATION INSTRUCTIONPLEASE READ ALL INSTRUCTION INCLUDING THE TIPS SECTION BELOW!5.1.INSTALL THE UNISTRUT OR THE REQUIRED CEILING STRUCTURE IN THE CEILING ABOVE THEWARMING STATION SO THAT THE CENTER OF THE TWO COLUMNS WILLBE 57”‐60” APART. GREATER WIDTHS MAY BE USED BUT COULD INTERFERE WITH MEDIA ENGINEPLACEMENT.5.2.BUILD AND ASSEMBLE CEILING MOUNT AS PER MANUFACTURER'S INSTRUCTIONSGENERAL NOTESSINGLE PROMO SCREEN - CEILING MOUNT:1.WHEN INSTALLING G.C TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS THAT COME WITH THEHARDWARE.2.NOT EVERY INSTALLATION METHOD CAN BE DOCUMENTED. G.C IS EXPECTED TO KNOW HOW TOATTACH TO ANY TYPE OF CEILING STRUCTURE. THESE INSTRUCTIONS WILL ASSUME THAT G.C ISATTACHING UNISTRUT TO THE STRUCTURE ABOVE THE CEILING.3.IN A PERFECT SITUATION THE SCREEN SHOULD BE CENTERED OVER THE BACK EDGE OF THECOUNTER, IN LINE WITH THE 3 MENU BOARDS SCREENS, AND NOT INTERFERE WITH THE SECURITYCAMERAS. CAMERAS ARE 360° AND LOOK AT THE CUSTOMER, CASH DRAWER AND CIGARETTE RACK.IF NECESSARY, THE SCREEN CAN BE LOCATED BACK FROM THE EDGE OF THE COUNTER.4.PROMO SCREEN MOUNT - HARDWARE4.1.SCREEN MOUNT ‐ CHIEF MCM1U4.2.UNISTRUT ADAPTOR CHIEF CMA3724.3.COLUMN - CHIEF CPA0724.4.COLUMN TO UNISTRUT CONNECTOR - CHIEF CPA2625.PROMO SCREEN MOUNT - INSTALLATION INSTRUCTIONS5.1.BUILD AND ASSEMBLE CEILING MOUNT AS PER MANUFACTURER'S INSTRUCTIONS.5.2.THE SCREEN MUST NOT INTERFERE WITH ANY WINDOW SHADES.5.3.DO NOT MIX UP THE FASTENERS FROM EACH OF THE COMPONENTS. MANY LOOK THE SAME.5.4.SET THE TILT ON THE SCREEN MOUNT TO 10 DEGREES5.5.MAKE SURE THE MOUNT IS LEVEL6.PIPE CUTTING6.1.ATTACH THE CPA262 COUPLER TO ONE END OF THE COLUMN AND SCREW INTO THEUNISTRUT ADAPTOR.6.2.DZ<d,,K>d,d/^dKZKsϵϬ͟Ksd,&>KKZ͘/&d,W/WK^EKdydEKtEdKϵϬ͟h^d,DKhEd/E'WK/Ed/^sZz,/',Ksd,/>/E'͕zKhE'K^,/',^ϵϴ͘͟6.3.MARK THE TOP EDGE OF THE HOLE BELOW AND CUT THE PIPE OFF AT THIS MARK.6.TRIPLE SCREEN MOUNT - INSTALLATION TIPS6.1.DO NOT MIX UP THE FASTENERS FROM EACH OF THE COMPONENTS. MANY LOOK THESAME.6.2.IF ANY OF THE INSTRUCTIONS GIVE YOU THE OPTION OF USING SECURITYVS. NON‐SECURITYSCREWS, CHOOSE THE NON‐SECURITY SCREWS.6.3.CENTER THE COLUMNS ON THE WARMING STATION. FIND THE MID‐POINT BETWEEN THEOUTER EDGE OF THE PIZZA WARMER AND THE LAST HOT DOG ROLLER AND MARK THEMIDDLE WITH MASKING TAPE OR SOMETHING SIMILAR. MARK UP IN THE CEILING OR ON THEUNISTRUT WHERE THIS IS AND INSTALL THE COLUMNS.6.4.CUT A HOLE IN THE CEILING TILE FOR THE COLUMNS, DO NOT CUT THE CEILING TILES INHALF.6.5.TO CENTER THE RAIL BETWEEN THE COLUMNS, MARK THE CENTRE OF THERAIL (54”), MEASURE THE MID‐POINT BETWEEN THE COLUMNS AND LINE UP YOUR MARK.6.6.IT IS NOT 100% CRITICAL TO HAVE THE COLUMNS CENTERED ON THE WARMINGEQUIPMENT AS THE RAIL CAN BE OFFSET SLIGHTLY.6.7.DO NOT FULLY TIGHTEN THE SET SCREWS ON THE ARRAY HEADS UNTIL THE HORIZONTALRAIL HAS BEEN INSTALLED AND LEVELED.ROOF TRUSSUNISTRUT ATTACHED TO BOTTOMCORD OF ROOF TRUSS WITH 14 GACLIP ANGLE ATTACHED TO THROUGHUNISTRUT USING THRU BOLTS ANDATTACHED TO TRUSS USING (2)#10TEK SCREWS (TYP.)UNISTRUT P1100DETAIL 5/A7.3SAMSUNG PREMIUMTIZEN POWEREDDISPLAY # PM49HCHIEF CPA SERIESCOLUMNCHIEF MEDIUM FLATPANEL CEILINGMOUNTTRIM THE END PIECESOF THE UNISTRUTP1100 CROSS BAR SOTHE ENDS OF THEUNISTRUT CROSS BARARE AS CLOSE TO THESTORE TRUSSES ASPOSSIBLE AND EVENON BOTH ENDSROOF TRUSSSAMSUNG PREMIUMTIZEN POWEREDDISPLAY # PM49HSAMSUNG PREMIUMTIZEN POWEREDDISPLAY # PM49H1GENERAL SINGLE OR MULTIPLE MENUBOARDS/PROMO SCREEN CEILING MOUNTING DETAIL3/4" = 1'-0"-22SIM.TYP.ROOF TRUSS14 GA. CLIP ANGLEUNISTRUT ATTACHED TOBOTTOM CORD OF ROOFTRUSSBOTTOM CHORD OFROOF TRUSS(2)#10 TEK SCREWS(TYP.)BOLTS2UNISTRUT TO TRUSS CHORD MOUNTING DETAIL3" = 1'-0"3883 Ruffin Road Suite B <br />San Diego, CA 92123 <br />p: 714/560/8200 <br />f: 714/560/8211 <br />www.tait.com <br />Since 1964 Los Angeles <br />Anaheim <br />Ontario <br />Sacramento <br />San Diego <br />Boise <br />Dallas <br />Denver <br />Seattle <br />©"TAIT & ASSOCIATES" 2020 ALL RIGHTS RESERVED <br />Job#: <br />Scale: <br />Date: <br />Drawn By: <br />Checked By: <br />Rev. #Date DescriptionSHEET:7-ELEVEN, INC. <br />3200 HACKBERRY, IRVING, TEXAS 75063 <br />SE1237 <br />7-ELEVEN 1046249 <br />1110 N. MAIN ST <br />MANTECA, CA 95336 <br />TICOFALCC 1 9 0 9 1L <br />11 / 21EXPIRESETSTAFOIA <br />NR SNI <br />C <br />E <br />EDCHRAIETA <br />EN <br />FR <br />JR.EK <br />ALLPNSIA7.2DIGITAL MENU BOARD INSTALLATION <br />GUIDE AND DETAILS