Laserfiche WebLink
2WORKSTATION WIRING-LOW VOLTAGEN.T.S.TYPICAL WORKSTATION ELEVATION. MAY NEEDMODIFICATION PER ACTUAL CONDITIONS.SWITCH10"x10" J-BOX IN SPACEABOVE WORKSTATION(1) 3"C TOTELEPHONE BOARD(1) 3"C TO 10"x10" J-BOX ABOVESALES COUNTER. STUB OUT (2)2"C INTO SALES COUNTER3" CONDUIT TOJ-BOX BELOW(1) 1"C TO ACCESSPOINT- WALK INCOOLER(1) 1"C TO ACCESSPOINT-SALES FLOOR(1) 1"C TO ATM(1) 1"C TOMANAGER'S OFFICE(1) 1"C TO ATG(FUELING ONLY)CEILING11D-1,D-2 &D-8(IF USED)T-49/50 T-30T-3910"x10" J-BOXFOR DATA &PHONE LINESD-4D-6D-7D-5 (FUELINGONLY)INSTALL LIGHTINGOVERRIDE SWITCHPROVIDED BY EMS.REF EMS1.0VEEDERROOTROUTER12132'-10" <br />TYP. <br />4'-0" <br />5'-8"16AA.1B1234BUN DRAWERWASTECIG'SCIG'SITPOTPFEM - CHIPS <br />MAGNUSHSSMAGNUSHSSMAGNUSHSS141E1.4335D-1D-3D-2D-4ROUTERPV LINKD-6667741LOW VOLTAGE PLAN1/4" = 1'-0"JJJ+144"+144"8T-30T-49/50ENHANCEDDISPENSER HUB911A11B11CD-7 &T-39101414V-6CLGMTDV-6CLGMTDV-6CLGMTDV-6CLGMTDJJ4J15CLGMTD152J4J4E1.41517LOW VOLTAGE NOTES:1.ALL WIRING IS COPPER. REFER TO ELECTRICAL SPECIFICATIONS FORFURTHER INFORMATION.2.E.C. TO INSTALL DATA LINES IN CONDUIT TO BOXES INSTALLED BY LOWVOLTAGE CONTRACTOR LTCG PRIOR TO TYCO CAMERA INSTALLATION.3.CONDUITS THAT ARE EXPOSED TO WIDELY DIFFERENT TEMPERATURES,SUCH AS COOLERS, FREEZERS OR SERVICE ENTRANCE CONDUCTORS,SHALL BE SEALED TO PREVENT CIRCULATION OF AIR AND/OR MOISTURE. REF2011 NEC (300.7 (A))4.CONDUIT AND WIRING IN AREAS WHERE EXPOSED SHALL BE ROUTED AT 90DEGREE ANGLES PERPENDICULAR OR PARALLEL TO JOISTS. COORDINATEPAINTING OF CONDUIT WITH ARCHITECTURAL FINISHES.5.UNLESS OTHERWISE DICTATED BY APPLICABLE CODES OR AHJ, ALL MATERIALS WITHIN RETURN AIR PLENUM MUST BE NON COMBUSTIBLE AND/OR HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX NOT MORE THAN 50 IN ACCORDANCE WITH ASTME 84 TESTING.KEYNOTES - LOW VOLTAGE1ENERGY MANAGEMENT ENCLOSURE PROVIDED BY OTHERS.2VIEW MONITOR: ROUTE CONDUIT BACK TO VIDEO RECORDINGEQUIPMENT LOCATED IN MANAGER'S OFFICE. COORDINATE LOCATIONWITH SECURITY SYSTEM INSTALLER. REFER TO LOW VOLTAGE RISERDIAGRAM FOR WIRING REQUIREMENTS.34SECURITY CAMERA:ROUTE CONDUIT BACK TO VIDEO RECORDINGEQUIPMENT LOCATED IN MANAGER'S OFFICE. COORDINATE LOCATIONWITH SECURITY SYSTEM INSTALLER.5VEEDER ROOT: COORDINATE INSTALLATION WITH FUELING PLANS.INSTALL IN ACCESSIBLE LOCATION. MOUNT AT 48" A.F.F. TO BOTTOM.6ROUTE WIRING FOR DATA DEVICES UNDER SLAB, RE: 1/E1.27MOUNT +12'AFF, ROUTE CONDUIT BACK TO VIDEO RECORDINGEQUIPMENT LOCATED IN MANAGER'S OFFICE. COORDINATE LOCATIONWITH CONSTRUCTION MANAGER AND SECURITY SYSTEM INSTALLER.8TELEPHONE BOARD: 4'X4'X3/4" PLYWOOD WITH (1) #6 CU.GROUND FOR FUTURE USE MOUNTED ABOVE 4'X4'X3/4"PLYWOOD WITH (1) #6 CU. GROUND PER TELE. CO.REQUIREMENTS.MOUNT RECEPTACLE ADJACENT TO ORABOVE TELEPHONE BOARD, DO NOT MOUNT BELOW.LOW VOLTAGE AND LINE VOLTAGE WIRING IN OPEN CEILING AREASSHALL BE ROUTED THROUGH A NONMETALLIC RACEWAY SYSTEM ATTHE STOREFRONT AND DOWN TRUSSES AS NEEDED. THERE SHALL BENO EXPOSED WIRING IN THE SALES AREA. OWNER TO PROVIDELEGRAND 400 SERIES SYSTEM WITH ALL FITTINGS AND DEVICE BOXESREQUIRED FOR CONNECTION TO EXIT SIGN. OWNER TO ALSO PROVIDEPANDUIT 2X2 FIBERRUNNER ROUTING SYSTEM FOR ALL LOW VOLTAGECABLING. RE:1/E1.4 FOR LOW VOLTAGE ROUTING.9CRADLEPOINT WIRELESS INTERNET CONNECTION. THIS WILL BE THELAST ISP RELATED DEVICE TO BE INSTALLED. THE LOCATION IN THESTORE WILL BE BASED ON THE STRONGEST SIGNAL WITHIN THE STORE.GUIDELINES FOR THE LOCATION OF THE CP ARE AS FOLLOWS:·AS FAR AWAY AS POSSIBLE FROM THE ELECTROMAGNETICINTERFERENCE (MOTORS)·AS CLOSE TO THE CEILING AS POSSIBLE·POSITIONED SO THE LED LIGHTING SIGNALS ARE VISIBLE FORTROUBLE SHOOTING / MAINTENANCE PURPOSES·MAXIMUM OF 4-6" OF PATCH CABLE VISIBLE ON THE WALL (COLOR:WHITE)10RJ11 FLUSH MOUNT FACE PLATE FOR ATM DATA LINE TO RISCOMPUTER WITH JACK TO BE LABELED 'ATM'. DATA LINEIDENTIFIER. D-711ACCESS POINT EXTENDED ANTENNA CABLES, FOUR CAT 6 CABLES,RJ45 FEMALE IN A 4-PLEX, COVER PLATE LABELED TO 3 LOCATIONSBELOW:A. CAT6 RJ45 FEMALE JACK CENTER OF SALES FLOORSUSPENDED ABOVE CEILING TILE (MAY NEED TO MOVE LATER).100' IN TOTAL LENGTH WITH EXTRA COILED AT FEMALE JACKB. CAT6 RJ45 FEMALE JACK CENTER OF SALES FLOORSUSPENDED ABOVE CEILING TILE (MAY NEED TO MOVE LATER).100' IN TOTAL LENGTH WITH EXTRA COILED AT FEMALE JACK.C. CAT6 RJ45 FEMALE JACK IN RECEPTACLE 84" ABOVE FLOOR- CENTER OF WALK-IN COOLER.12DATA TELEPHONE CABLING PROVIDED BY LTCG. CONTACTGREGORY LEVALDS (972) 801-9950. CONDUIT AND BOXES TO BEFURNISHED BY OWNER AND INSTALLED BY G.C.1324"x36" FIRE RETARDANT U-TECK BACKBOARD SHALL BE PLACEDBEHIND RIS MONITOR AND ABOVE WORKSTATION RECEPTACLES.BACKBOARD WILL SUPPLY MOUNTING FOR SRX ROUTER AND RISSWITCH. PROVIDED AND INSTALLED BY LTCG.14FOUR DIGITAL MENU BOARDS (DMB) WITH MEDIA PLAYERS.INCLUDED IN ALL U.S. NEW STORE PROJECTS AND ALL U.S.REVITALIZATION PROJECTS (REBUILD, RELOCATION, MAJORREMODEL) EFFECTIVE 1/01/2018. HARDWARE SEI SUPPLIEDTHROUGH CONTACT WITH AT&T (CONSOLIDATED PO TO AT&TTHROUGH TURNKEY RESOURCES). ELECTRICAL POWER AND LOWVOLTAGE POWER BY GC. COMMISSIONING IS SEI SUPPLIEDTHROUGH CONTRACT AT&T (DIRECT PO TO AT&T). SUBSCRIPTIONAND SERVICE AGREEMENT(S) BILLED DIRECT TO SEI ITDEPARTMENT SEPARATE FROM CONSTRUCTION PROJECTS.1516QSIC DATA AND SPEAKER WIRE TO COME OUT OF 6 WAY DATAOUTLET (DATA TO BE TERMINATED, BLANKS LEFT FOR SPEAKERAND AVA WIRE TO COME OUT).17AVA WIRE TO TERMINATE IN BACK OF AVA SENSOR. MOUNT INCEILING.QSIC MUSIC SERVICE 3 SPEAKERS WITH CAT6 TERMINATED TOFEMAILE RJ45. DATA JACKS FOR SPEAKER TO BE FLUSH MOUNTEDDIRECTLY BEHIND SPEAKER. VERIFY EXACT HEIGHT AND LOCATIONWITH ARCHITECTURAL DRAWINGS. INSTALLER TO HIDE DATA CABLEBEHIND THE SPEAKER USING CABLE TIES.(1) 2"CT-49/50T-39 (FAX)(1) 1"C TO TELEPHONEBOARD(1) 1"C TO VIDEO CAMERAS(1) 2"C TO SALES COUNTER(1) 1"C TO WORKSTATION(1) 1"CREFER TO ARCH INTERIOR OFFICEELEVATIONS FOR EXACT DIMENSIONS3MGR'S OFFICE WIRING-LOW VOLTAGEN.T.S.DESKSECURITY ALARM PANELCEILINGNETWORK SWITCH FORDIGITAL MENU BOARD4WALL SECTION AT STOREFRONTN.T.S.8ROUTE PANDUITRACEWAY ALONGBOTTOM CHORD OFJOIST. PAINT TO MATCHSURROUNDINGCONDITIONS(3) #12 TO EXIT SIGNABOVE ENTRY DOOR. INLEGRAND 400 SERIESRACEWAY. PAINT TOMATCH SURROUNDINGCONDITIONS.(6) CAT. 6 CABLES, (1)TO EACH SECURITYCAMERA AND (1) TOVIEW MONITOR AND (1)TO EACH ANTENNALOCATION.EXIT SIGNLEGRAND 400 SERIESRACEWAY TURNEDDOWN TO EXIT SIGNRE: SOFFIT LIGHTWIRING DETAIL ONSHEET E2.0.PHONESDESIGNATIONLINECONDUITSIZEFROMTOT-49/50STORE VOICE LINE,LOCATED AT SALESAREA, MGR'S OFFICE& RIS WORK STATION.THROUGHCONDUIT1"TELEPHONE BOARDBACK ROOM 10" X 10"J-BOX & THEN TOFRONT SALESCOUNTERT-30MONEY ORDER, LONGDISTANCE CARDS(LDC) AND EBT (FOODSTAMP PROGRAM)THROUGHCONDUIT1"TELEPHONE BOARD TORIS, FROM RIS 10" X 10"TO SALESFRONT SALESCOUNTERT-39FAX LINE AT RISWORKSTATIONTHROUGHCONDUIT1"TELEPHONE BOARD ABOVECLG TO RIS 10" X 10"WORKSTATIONT-75V-COM LINETHROUGHCONDUIT1"TELEPHONE BOARDATM LOCATIONNOTE: ALL PHONE LINES TRAVEL FROM DEMARC THROUGH 3" CONDUIT TO 10" X 10" J-BOX MOUNTED ABOVE ISP.DATADESIGNATIONLINECONDUITSIZEFROMTOD-1COMPUTER ATREGISTER #1IN SLAB1"10" X 10" J-BOX @WORKSTATION AREASALES AREAD-2COMPUTER ATREGISTER #2IN SLAB1"SALES AREAD-3HOLD-UP BUTTONIN SLAB1"SALES AREA -REGISTER #1D-4MONEY ORDERIN SLAB1"D-5ATG1"(ELECTRIC ROOM)FUEL TANKSD-6LOTTO1"SALES AREATHROUGH CONDUITIN SLABNOTE: ALL DATA LINES TRAVEL FROM DEMARC THROUGH 3" CONDUIT TO 10" X 10" J-BOX IN CEILING, DOWNTHROUGH WALL INTO 10" X 10" J-BOX BEHIND RIS DESK.D-7ATM1"VCOM WALLTHROUGH OVERHEADCONDUITCAMERA SIGNALTHROUGH CEILINGTHROUGH CONDUITTO ELECTRIC ROOM10" X 10" J-BOX @WORKSTATION AREAMGRS OFFICE10" X 10" J-BOX @WORKSTATION AREA10" X 10" J-BOX @WORKSTATION AREAISP DESK - ATG MONITOR10" X 10" J-BOX @WORKSTATION AREA10" X 10" J-BOX @WORKSTATION AREASALES AREA -REGISTER #1SALES AREA -REGISTER #2Job#: <br />Scale: <br />Date: <br />Drawn By: <br />Checked By: <br />Rev. #Date DescriptionSHEET:7-ELEVEN, INC. <br />3200 HACKBERRY, IRVING, TEXAS 75063 <br />SE1237 <br />7-ELEVEN 1046249 <br />1110 MAIN ST <br />MANTECA, CA 95336 <br />MS <br />RES <br />10/29/2020E1.4LOW VOLTAGE FLOOR PLAN