ELECTRICAL SPECIFICATIONINTRODUCTIONTHE CONTRACTING FOR INSTALLATION OF THE ELECTRICAL SYSTEM WILL BE ACCOMPLISHED IN THE FIELD AT THEDIVISION LEVEL. THESE SPECIFICATIONS ARE TO AID IN PREPARATION OF DIVISION LEVEL STORE PLANS AND CONTRACTDOCUMENTS. IN CASE OF A CONFLICT BETWEEN THIS SPECIFICATION AND THE CONTRACT DOCUMENTS PROVIDED BYTHE DIVISION CONSTRUCTION MANAGER, THE DIVISION'S PLANS AND SPECIFICATIONS SHALL PREVAIL.DEFINITIONSTHE FOLLOWING DEFINITIONS APPLY TO THIS PROJECT.FURNISH - TO SUPPLY THE MATERIAL NECESSARY TO PERFORM THE TASK.INSTALL - TO SUPPLY THE LABOR NECESSARY TO COMPLETE THE TASK.PROVIDE - TO FURNISH AND INSTALL MATERIAL AND LABOR TO COMPLETE THE TASK.1. SCOPE2. INSTALLATION3. MATERIALS:1.11.21.31.41.51.61.72.12.22.32.42.52.62.7ALL MATERIALS AND DEVICES SHALL BE UL APPROVED AND SHALL CONFORM TO THE STANDARDS OF NEMA, NEC,AND IEEE.3.13.23.33.43.5E.C. TO PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT (U.N.O.) REQUIRED TO EXECUTE WORK PER NEC ANDALL APPLICABLE ELECTRICAL CODES IN FORCE AT THE TIME OF PROJECT COMPLETION.THIS WORK INCLUDES, BUT IS NOT LIMITED TO: ELECTRICAL SERVICE AND DISTRIBUTION SYSTEMS, PANELBOARDS,DISCONNECT SWITCHES, LIGHTING FIXTURES, POWER AND CONTROL WIRING WITH FINAL CONNECTIONS TO ALLEQUIPMENT REQUIRED FOR A COMPLETE SYSTEM.E.C. TO VERIFY TYPE OF POWER SERVICE AVAILABLE (UNDERGROUND OR OVERHEAD) ANDMAXIMUM SHORT CIRCUIT CURRENT PRIOR TO SUBMITTING A PROPOSAL.E.C. TO VERIFY TYPE OF TELEPHONE SERVICE AVAILABLE (UNDERGROUND OR OVERHEAD)PRIOR TO SUBMITTING A PROPOSAL.E.C. TO VERIFY METERING, IN ACCORDANCE WITH LOCAL ELECTRIC UTILITY COMPANY REQUIREMENTS, FORGENERAL SERVICE SCHEDULE.E.C. SHALL INSTALL 3-PHASE 4-WIRE 120/208V WYE SERVICE. IF FOR ANY REASON, THIS ISNOT AVAILABLE, THE E.C. SHALL NOTIFY 7-ELEVEN, IN WRITING PRIOR TO SUBMITTING OFPROPOSAL (U.N.O.).E.C. TO PROVIDE PANELBOARD NAMEPLATES. PROVIDE LAMINATED PLASTIC NAMEPLATES WITH 3/4 INCHMINIMUM CONTRASTING-COLOR ENGRAVED LETTERS IDENTIFYING EACH PANELBOARD.THE INSTALLATION SHALL COMPLY WITH ALL LAWS IN EFFECT AT THE TIME OF CONSTRUCTION APPLYING TOELECTRICAL INSTALLATION, AND WITH THE REGULATIONS OF THE NEC, WHERE SUCH REGULATIONS DO NOTCONFLICT WITH THE LAWS IN EFFECT, AND WITH THE PUBLIC UTILITY COMPANY FURNISHING THE SERVICE.2.1.1E.C. SHALL PROVIDE ALL REQUIRED ELECTRICAL CONDUIT AND WIRING FOR ALL MOTORS, MOTOR STARTERSAND ELECTRICAL CONTROLS, U.N.O. E.C. SHALL MAKE ALL LINE VOLTAGE ELECTRICAL CONNECTIONS ASREQUIRED FOR HVAC SYSTEMS.E.C. SHALL INSTALL THE CONNECTIONS TO ALL RECEPTACLES, SALES COUNTERS,GONDOLAS AND FINAL CONNECTIONS TO ALL FIXTURES AFTER FIXTURES ARE IN PLACE.E.C. SHALL VERIFY EXACT LOCATION OF ALL SIGNS WITH 7-ELEVEN REPRESENTATIVE. PROVIDE ALL CONDUITS ANDWIRES WITH STUB-UPS AS DIRECTED BY THE 7-ELEVEN CORPORATION AND INSTALL FINAL CONNECTIONS ASREQUIRED.WIRING2.5.12.5.22.5.32.5.42.5.52.5.62.5.72.5.8WHEN REQUIRED, E.C. TO ENSURE INTEGRITY OF FIRE RATED WALLS WHERE ELECTRICAL EQUIPMENTPENETRATES WALLS. SEAL PER SPECIFICATIONS FOR FIRE STOPPING.ALL PENETRATIONS THROUGH EXTERIOR WALLS ARE TO BE MADE WITH LB CONDULETS OF THE APPROPRIATESIZE PER NEC. ALL PENETRATIONS ARE TO BE SEALED PER NEC. HORIZONTAL OR VERTICAL SUPPORTS FORRACEWAYS ARE TO COMPLY WITH NEC. WIRE TIES ARE NOT TO BE USED, U.N.O.LIGHT FIXTURES: PER SCHEDULE ON ELECTRICAL PLAN.RACEWAYS: ALL CONDUIT SHALL BE EITHER RIGID STEEL OR ELECTRICAL METALLIC TUBING (EMT). FOR IN SLABAND UNDERGROUND INSTALLATIONS, PVC OR RIGID STEEL SHALL BE USED. REFER TO FUELING SHEETS FORAPPROVED FUELING SYSTEMS CONDUIT. INSTALL PER NEC.FITTINGS AND BUSHINGS:ALL REQUIRED BENDS, FITTINGS, JUNCTION BOXES, ETC., WHETHER OR NOT THEY ARESHOWN ON THE DRAWINGS, SHALL BE INSTALLED TO SATISFY ALL APPLICABLE ELECTRICAL CODES AND STANDARDSOF GOOD PRACTICE. ALL CONDUCTORS ENTERING/LEAVING A CONDUIT OR RACEWAY SHALL BE AFFORDEDABRASION PROTECTION BY AN ADEQUATE BUSHING OR OTHER APPROVED MEANS.OUTLET BOXES: SHALL BE STANDARD, STAMPED GALVANIZED STEEL BOXES; "J"-BOXES AND OUTLET BOXES USED ASA PULL BOX SHALL BE PROVIDED WITH A SUITABLE COVER OF SAME MATERIAL AS BOX.WIRING DEVICES:INSTALL ON EACH AND EVERY OUTLET BOX, A WIRING DEVICE AND/OR COVERPLATE, ALL AS INDICATED BY SYMBOLON THE DRAWINGS.3.5.1THE E.C. SHALL UPGRADE THESE SPECIFICATIONS AS REQUIRED TO MEET COMPLIANCE WITH ALLAPPLICABLE CODES IN EFFECT; HOWEVER, WHERE THESE SPECIFICATIONS MAKE STIPULATIONS OVER ANDABOVE THE MINIMUM REQUIREMENTS OF APPLICABLE CODES, THE CONTRACTOR SHALL NOT DOWN-GRADETHESE SPECIFICATIONS TO MINIMUM CODE REQUIREMENTS WITHOUT PRIOR WRITTEN APPROVAL FROM7-ELEVEN.ALL WORK SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. THE E.C. SHALLCONTACT THE 7-ELEVEN CORPORATION REPRESENTATIVE SHOULD THIS PLAN REQUIRE MODIFICATION TOCOMPLY WITH LOCAL CODES.ALL CONDUCTORS SHALL BE RUN IN APPROVED METALLIC RACEWAY OR CONDUIT AND SHALL BE UNIFORMLYCOLOR CODED THROUGHOUT THE ENTIRE SYSTEM. SPLICES, TAPS, AND TERMINALS SHALL BE MADE ONLY INJ BOXES, OUTLET BOXES AND PANELBOARDS.THE E.C. SHALL ENSURE THE CONDUCTORS UTILIZED ARE IN KEEPING WITH GOOD PRACTICE FOR THE CIRCUIT/PROTECTIVE DEVICES EMPLOYED. THE NEUTRAL CONDUCTOR (WHERE USED) SHALL HAVE THE SAME AMPACITY AS THE ASSOCIATED PHASE.THE E.C. SHALL ENSURE THAT CIRCUIT AMPACITY AND SHORT CIRCUIT/OVERLOAD PROTECTION ISAPPROPRIATE FOR THE EQUIPMENT BEING INSTALLED. UL LISTING CONDITIONS SHALL BE OBSERVED.TO COMPLY WITH NEC/UL LISTING CONDITIONS, ROOFTOP UNITS MAY BE SHOWN WITH FUSEDDISCONNECT SWITCHES:2.5.5.12.5.5.2WIRE SIZES LISTED ARE MINIMUM. CONDUCTORS SHALL BE SELECTED SUCH THAT THE MAXIMUM VOLTAGEDROP (AT FULL LOAD AMPS) SHALL NOT EXCEED THE FOLLOWING GUIDELINES:2.5.6.12.5.6.22.5.6.3SPECIAL NOTES ON SERVICES:2.5.7.1THE E.C. SHALL PROVIDE DEDICATED CIRCUITS WITH ISOLATED GROUND FOR ALL CIRCUITSORIGINATING FROM PANEL S. THE PURITY OF THE ISOLATED GROUND SHALL BE MAINTAINED BY USING ONLYINSULATED GROUNDING CONDUCTORS AND ISOLATED GROUND. THE GROUNDING CONDUCTOR FOR THE .ISOLATED GROUND SHALL NOT MAKE ELECTRICAL CONTACT WITH THE COMMON EQUIPMENT GROUND ORANY ITEM CONNECTED TO THE COMMON EQUIPMENT GROUND (I.E. CONDUITS, "J"-BOXES, SWITCH BOXES,ETC.) AT ANY POINT OTHER THAN AT THE SERVICE GROUNDING TERMINAL. SEE NEC 250.96(B).WALL SWITCHES:ALL FUSES SERVING MOTOR LOADS WILL BE OF THE DUAL ELEMENT TYPE.DUE TO DIFFERENT INTERRUPTING CHARACTERISTICS, PANELBOARD CIRCUIT BREAKERS MAY BERATED HIGHER THAN THE DUAL ELEMENT FUSES THEY SUPPLY TO ENSURE SUFFICIENT STARTINGCURRENT.PANEL FEEDERS --2% OF CIRCUIT VOLTAGE AT SERVICE.ALL BRANCH LOADS--3% OF CIRCUIT VOLTAGE AT SERVICE.TOTAL VOLTAGE DROP (SERVICE TO LOAD)--5% OF CIRCUIT VOLTAGE AT SERVICE.120/208V, 3-PHASE, WYETHE E.C. SHALL CHECK THE REQUIREMENTS OF ALL EQUIPMENT AND WILL INSTALLAUTOTRANSFORMERS (BUCK AND BOOST TRANSFORMERS) AS REQUIRED.3.63.73.5.23.5.33.5.43.5.53.5.63.5.73.5.83.5.93.5.103.5.113.5.12SERVICE/DISTRIBUTION EQUIPMENT:PANEL AND DISTRIBUTION PANEL SHALL BE SQUARE 'D'. ALL SWITCH GEAR TO BE FURNISHED FROMGRAYBAR, U.N.O. FOR PRICING AND PLACING ORDERS, CONTACT `7-ELEVEN' FOR THE APPROPRIATESALES DEPARTMENT.3.6.13.6.23.6.3OVERCURRENT/SHORT CIRCUIT PROTECTIVE DEVICES:3.7.13.7.23.7.33.5.1.13.5.1.2NOT USED CONVENIENCE OUTLET (20A):20A CONVENIENCE OUTLETS SHALL BE SIMILAR AND EQUIVALENT TO "LEVITON" #CR20-W2 POLE, 3 WIRE, 20 A 125V, DUPLEX GROUNDING RECEPTACLE WITH (WHITE) COVERPLATESIMILAR AND EQUIVALENT TO "LEVITON" #88003 FOR SINGLE DUPLEX OR "LEVITON" #88016 FOR DOUBLE DUPLEX (QUAD). OUTLET, ISOLATED GROUND (20A):ISOLATED GROUND OUTLETS SHALL BE SIMILAR AND EQUIVALENT TO "LEVITON" #5362-IG2 POLE, 3 WIRE, 20A, 125V, SINGLE, ISOLATED GROUND RECEPTACLE (ORANGE) WITH(WHITE) COVERPLATE.GFCI CONVENIENCE OUTLETS (INDOOR & OUTDOOR):OUTDOOR GFCI OUTLETS SHALL BE WEATHER RESISTANT (WR) LABELED, EQUIVALENT TOTHE "LEVITON" #WR899-W 20A OUTLET WITH OUTDOOR COVERPLATE #4500B AND BACKPLATE #63101. INDOOR GFCI OUTLETS SHALL BE EQUIVALENT TO "LEVITON" #7899-W, 20AWITH (WHITE) COVERPLATE.NOT USEDSAFETY SWITCHES:SAFETY SWITCHES SHALL BE UL APPROVED GENERAL DUTY SAFETY SWITCHES WITH LOCK OFFHANDLES SIMILAR AND EQUIVALENT TO THOSE MANUFACTURED BY "SQUARE-D". SWITCHESWILL BE FUSIBLE OR NON-FUSIBLE AS INDICATED ON PLANS/LOCAL CODES AND WILL BE NEMATYPE 1 FOR INDOOR (DRY) INSTALLATION OR A NEMA TYPE 3R ENCLOSURE FOR OUTDOORINSTALLATION. FUSED SWITCHES SHALL HAVE REJECTION STYLE FUSE HOLDERS TO MATCHLPN-RK CLASS RK1 FUSES.NOT USEDPHOTO CELL (OUTDOOR):ELECTRONIC LIGHT SENSOR SHALL BE THE TORK EPC-1. ENCLOSED IN A LEXAN HOUSINGWITH A 1/2" CONDUIT MOUNTING AND 180 DEGREE SWIVEL. INSTALL IN A WEATHERTIGHT JUNCTION BOX ON THE ROOF PER MANUFACTURER'S RECOMMENDATIONS. SETSENSOR TO 100 FOOT-CANDLE LEVEL.3.5.9.1CONTACTOR (OUTDOOR LIGHTING CONTROL):THE LIGHTING CONTACTORS FOR USE WITH THE OUTDOOR PHOTO CELLS SHALL BESIMILAR AND EQUIVALENT TO "SQUARE-D" ELECTRICALLY HELD LIGHTING CONTACTORCLASS 8903 TYPE LG-80 FORM F WITH 120V CONTROL COIL, NORMALLY OPEN CONTACTSRATED AT 30 AMPS CONTINUOUS, IN NEMA TYPE 1 ENCLOSURE WITH FUSED CONTROLCIRCUIT. REF LIGHTING CONTACTOR DETAIL.PHOTO CELL BYPASS SWITCH:THE PHOTOCELL BYPASS SWITCH SHALL BE A "BRYANT" #4801-L SINGLE POLE LOCKTYPE 15A 120-277 VOLT SWITCH WITH KEY #6006 AND COVERPLATE (WHITE).NOTE: NO SUBSTITUTION SHALL BE PERMITTED UNLESS THE E.C. CAN PROVE TO THE 7-ELEVENCORPORATION REPRESENTATIVE THAT THE PROPOSED SUBSTITUTE WILL OPERATE WITH "BRYANT" KEY #6006. THE KEY SHALL BE TURNED OVER TO THE 7-ELEVEN CORPORATIONREPRESENTATIVE AT ACCEPTANCE (NOT LEFT IN SWITCH, CASH REGISTER, ETC.).HEAT TRACE - FREEZER PIPE FREEZE PROTECTION (WHEN REQUIRED):HEATING CABLE: FURNISH RAYCHEM 5XL1-CR WITH RAYCLIC-PC ELECTRICAL CONNECTION. XLTRACE BY TYCO THERMAL CONTROLS, LLC. FOR EXTRA INFORMATION CONCERNING HEAT TRACESYSTEM CONTACT DAN PETERSEN WITH INDUSTRIAL HEATER (901-382-4761).CIRCUIT BREAKER: PROVIDE SQUARE 'D' Q0120EPD OR EQUIVALENT GFCI CIRCUIT BREAKER WITH30mA TRIP.NOTE: MECHANICAL CONTRACTOR TO INSTALL SELF REGULATING HEATING CABLE PERMANUFACTURER'S REQUIREMENTS ON CONDENSATE DRAIN LINES INSIDE FREEZER BOXES THATARE TO OPERATE AT OR BELOW 32 DEGREES F.MAIN POWER SWITCHESTHE MAIN PANEL POWER SWITCHES/CIRCUIT BREAKERS SHALL BE SQUARE 'D' TYPE I LINE, RATED AT 65,000A.I.C. (MIN.) SWITCHES OR CIRCUIT BREAKERS SHALL BE LISTED AS INDICATED ON PLANS.NOTE: PANEL RATINGS REQUIRED FOR HIGHER AIC REQUIREMENTS SHALL BE PRESENTED TO THEDISTRIBUTOR FOR MODIFICATIONS TO THE GEAR SUBMITTAL.PANELBOARDS:SQUARE 'D' PANELBOARDS USED IN SERIES WITH I-LINE CIRCUIT BREAKERS AND FITTEDWITH SQUARE 'D' BRANCH CIRCUIT BREAKERS ARE AS INDICATED ON PLANS.USE AN APPROPRIATE SQUARE 'D' CIRCUIT BREAKER WITH EACH PANEL. CIRCUITBREAKERS SHALL BE TYPE QOXXX-"QO"-FRAME3.6.2.13.6.2.2WIREWAY:THE WIREWAY SHALL BE SIMILAR AND EQUIVALENT TO "SQUARE D COMPANY" WIREWAY WITHAPPROPRIATE FITTING FOR THE PARTICULAR INSTALLATION. E.C. SHALL SIZE TO INSTALLATIONIN ACCORDANCE WITH NEC, GOOD PRACTICE AND CODES IN EFFECT AT TIME OFINSTALLATION.PANELBOARD BRANCH/FEEDER CIRCUIT BREAKERS:ALL DOWNSTREAM BREAKERS MUST BE SQUARE 'D' TO MAINTAIN SERIES LISTING. IFFUSIBLE DISCONNECTS ARE USED, SQUARE 'D' PANEL BOARDS AND CIRCUIT BREAKERSSHALL BE USED.GROUND FAULT CIRCUIT INTERRUPTER (GFCI) BREAKERS:GROUND FAULT CIRCUIT INTERRUPTER (GFCI) TYPE CIRCUIT BREAKERS SHALL BESIMILAR TO THE PANELBOARD CIRCUIT BREAKERS BUT WITH GROUND FAULTPROTECTION WITH MATCHING A.I.C. RATING. GFCI BREAKERS SHALL BE ULAPPROVED AS CLASS A DEVICES IN ACCORDANCE WITH UL STANDARD #943.FUSES, MAIN SWITCHBOARD:MAIN SWITCHBOARD FUSES, IF REQUIRED, SHALL BE CLASS J CURRENT LIMITING FUSESAS INDICATED ON PLANS.SINGLE POLE SWITCHES:SINGLE POLE WALL SWITCHES SHALL BE SIMILAR AND EQUIVALENT; TO "LEVITON"#CS120-2W 20A, 120-277VAC TOGGLE SWITCH (WHITE) WITH COVERPLATE FOR SINGLEGANG OR (WHITE) COVERPLATE FOR DOUBLE GANG.3-WAY SWITCHES:3-WAY SWITCHES SHALL BE SIMILAR AND EQUIVALENT TO "BRYANT" #4503-I 20A,120-277VAC 3-WAY SWITCH (WHITE HANDLE) AND (WHITE) COVERPLATE FORSINGLE GANG OR (WHITE) COVERPLATE FOR DOUBLE GANG.LIGHTING CONTROLLER (OUTDOOR LIGHTING CONTROL):THE LIGHTING CONTROLLER SHALL BE THE TORK LC-200 IN A NEMA 1 ENCLOSURE.THE LC-200 IS USED IN CONJUNCTION WITH THE TORK EPC-1 PHOTOCELL. LIGHTINGCONTROLLER HAS A 2 TO 100 FOOT-CANDLE LIGHT ADJUSTMENT.UPON COMPLETION OF WORK, E.C. SHALL PROVIDE A TYPED DIRECTORY IN EACHPANELBOARD. INCLUDE SYSTEM VOLTAGE, PHASING, CIRCUIT NUMBERING AND DESCRIPTIONS.4. TESTING AND INSPECTIONNOTE: WITH 3 PHASE DELTA, PHASES A AND C SHALL BE BALANCED WITHIN 10% PHASE B(HIGH LEG) SHALL BE BALANCED AS CLOSELY AS POSSIBLE.5. INDUSTRY-STANDARDS3.7.43.83.94.14.24.35.1rev 6/2016FUSES, EQUIPMENT:EQUIPMENT FUSES, IF REQUIRED, SHALL BE OF THE DUAL ELEMENT, TIME DELAY VARIETYAS INDICATED ON PLANS. FUSES FOR HVAC/REFRIGERATION SHALL BE SIMILAR AND EQUIVALENTTO COOPER BUSSMANN FUSE TYPE LPN-RK-SP, CLASS RK1 FOR THE APPROPRIATE AMPERAGE.SPD SHALL BE PROVIDED BY GRAYBAR.CONDUCTORS:ALL CONDUCTORS SHALL BE COPPER, TYPE THHN, UNO. MINIMUM CONDUCTOR SIZE SHALL BE#12 AWG. CONDUCTORS #10 AWG AND LARGER SHALL BE STRANDED. INSULATION TYPE SHALLCONFORM WITH N.E.C. OR MANUFACTURER REQUIREMENTS. LIGHT FIXTURES SOMETIME REQUIRE90 DEGREE WIRE. FOR THE PARTICULIAR APPLICATION. USE TYPE THWN IN WET LOCATIONS.3.9.13.9.23.9.3TESTING:4.1.14.1.2INSPECTION:E.C. SHALL FURNISH AT THE COMPLETION OF THE PROJECT OREACH INSPECTION POINT OF THE PROJECT, AN INTERMEDIATE OR FINAL INSPECTIONCERTIFICATE FROM THE LOCAL INSPECTING AUTHORITY.PERFORMANCE REQUIRED:4.3.14.3.2THE FOLLOWING IS A LIST OF ABBREVIATIONS USED IN THE ELECTRICAL NOTES ANDSPECIFICATIONS.NEC.....................NATIONAL ELECTRIC CODE, REF. COVERSHEET FOR APPLICABLE VERSIONNEMA..................NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONUL........................UNDERWRITERS LABORATORIES, INC.HVAC...................HEATING, VENTILATING AND AIR CONDITIONINGIEEE......................INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERSGFCI.....................GROUND FAULT CIRCUIT INTERRUPTERAIC.......................AMPERES INTERRUPTING CAPACITYUNO.....................UNLESS NOTED OTHERWISEEC.........................ELECTRICAL CONTRACTORGC.........................GENERAL CONTRACTORNM CABLE (ROMEX) SHALL NOT BE USED.ALUMINUM CONDUCTORS SHALL NOT BE USED U.N.O.METAL-CLAD CABLE (MC) SHALL BE PERMITTED FOR USE AS BRANCH CIRCUITSIN WALL, CEILING OR CABINETRY.THE E.C. SHALL TEST, PRIOR TO ENERGIZING FOR THE FIRST TIME,ALL PIECES OF ELECTRICAL EQUIPMENT TO ASSURE THEY HAVE THEPROPER PHASE TO PHASE AND PHASE TO GROUND INSULATION AND TO BEFREE OF SHORTS. AFTER ENERGIZING, EACH LUMINAIRE SHALL BE LITAND TESTED.THE VARIOUS CIRCUITS SERVED FROM THE PANELBOARDS VARY IN LOADING.THE E.C. SHALL CAREFULLY BALANCE THE LOAD ON EACH LEG OFTHE SERVICE. WHEN ALL LOAD IS TURNED ON AND THE SYSTEM IS OPERATINGAT 100%, THE INITIAL UNBALANCE SHALL NOT EXCEED 10%.ALL EQUIPMENT AND FIXTURES SHALL BE PROPERLY CONNECTED WITHADEQUATE POWER AND CHECKED THOROUGHLY FOR PROPER OPERATION.ALL EXPOSED EQUIPMENT SHALL BE INSTALLED AS PER DRAWINGS AND ISSUBJECT TO INSPECTION FOR WORKMAN-LIKE APPEARANCE.3.5.1.3SINGLE THROW, DOUBLE POLE EVAPORATOR SWITCHSINGLE THROW, DOUBLE POLE SWITCHES SHALL BE SIMILAR AND EQUIVALENT TO "BRYANT"#30322D 120-600VAC NEMA 3R ENCLOSED AC MANUAL MOTOR CONTROLLER/DISCONNECT.PANEL 'F', IF REQUIRED, SHALL BE FED BY A SQUARE 'D' NO. 8903SQG2V02 CONTACTORAND SHALL BE WIRED FOR EMERGENCY SHUT DOWN.6. UTILITY ACCOUNT OPEN PROCESS6.1GENERAL CONTRACTOR (GC) WORKS WITH THE UTILITY COMPANIES TO SET UP ALLREQUIRED METERS AND ACCOUNTS ( ELECTRIC, NATURAL GAS, WATER) UNDER THEGC COMPANY NAME6.2FOR CORPORATE AND NON BCP FRANCHISEE, GC OBTAINS OPEN FACILITY REQUESTFORM FROM DEVELOPMENT PROJECT MANAGER (DPM). BLANK FORM IS LOCATED AT7-ELEVEN HUB / OPERATIONS / DEVELOPMENT PROGRAM MANAGEMENT QUICK LINKS6.3AT LEAST FIFTEEN (15) DAYS PRIOR TO THE STORE OPEN DATE, GC MAILSCOMPLETED OPEN FACILITIES REQUEST FORM TO ECOVA AT7-ELEVENOPCL@ECOVA.COM WITH A COPY TO THE DPM6.4BCP FRANCHISEES SET UP THEIR OWN UTILITIES AND THIS SET UP DOES NOT GOTHROUGH 7-ELEVEN,INCJob#:
<br />Scale:
<br />Date:
<br />Drawn By:
<br />Checked By:
<br />Rev. #Date DescriptionSHEET:7-ELEVEN, INC.
<br />3200 HACKBERRY, IRVING, TEXAS 75063
<br />SE1237
<br />7-ELEVEN 1046249
<br />1110 MAIN ST
<br />MANTECA, CA 95336
<br />MS
<br />RES
<br />10/29/2020E3.0ELECTRICAL
<br />SPECIFICATIONS
|