DATE:APEXPROJECT:Copyright APEX845 S. Commerce StreetStockton, CA. 95206(209) 662-4874apexplanning@hotmail.comSteven Anthony Torres IIArchitect # C32553APEXARCHITECTUREREV.#DESCRIPTIONDATE ISSUEDCheveron CAR WASH2-26-202120-212494 E. Fremont St.Stockton, CA 95205HCSEngineering50 yearsHTIMSC.DRAH <br />CIR <br />No. E14303Exp. 6-30-23ELECTRICA <br />LREGISTER <br />E <br />D <br />PROFESSIONALENGINEEREOFCALI <br />FOR <br />NIASTAT 4512 Feather River Dr #F, Stockton, CA 95219209-478-8270 | www.hcs-eng.comRichard C. Smith, PE richard@hcs-eng.comBhupendra Patel, PE bhupendra@hcs-eng.comElizabeth Aguilar elizabeth@hcs-eng.comPROJECT # 2020.402E0.1GENERAL NOTES260500 ELECTRICAL WORK FOR COMMON RESULTS:1. ELECTRICAL INSTALLATION SHALL COMPLY WITH TITLE 24, CALIFORNIACODE OF REGULATIONS, INCLUDING THE FOLLOWING:TITLE 24, CCR, PART 2, 2019 CBCTITLE 24, CCR, PART 3, 2019 CECTITLE 24, CCR, PART 4, 2019 CMCTITLE 24, CCR, PART 9, 2019 CFCTITLE 24, CCR, PART 6, 2019 CALIFORNIA ENERGY CODETITLE 24, CCR, PART 11, 2019 CALIFORNIA GREEN BUILDING STANDARDS CODEALL APPLICABLE LOCAL CODES2. ELECTRICAL CONTRACTOR SHALL VERIFY POWER, TELEPHONE AND CABLE TV SERVICES AT SITE PRIORTO BIDDING. SERVICES TO CONFORM TO UTILITY COMPANY REQUIREMENTS. ELECTRICAL CONTRACTORSHALL ARRANGE FOR SERVICE INSTALLATIONS PER UTILITY COMPANY REQUIREMENTS AND PAY ALLCUSTOMER CHARGED SERVICE COSTS. COORDINATE WITH OWNER AND UTILITY COMPANY FOR SERVICEINSTALLATION.3. CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, LICENSES, ETC. REQUIRED TO CARRY ONAND COMPLETE THE WORK.4. PROVIDE ALL LABOR, MATERIALS, TOOLS, PLANT EQUIPMENT, TRANSPORTATION AND PERFORM ALLOPERATIONS NECESSARY FOR ANY REASONABLE INCIDENTAL TO PROPER EXECUTION AND COMPLETIONOF ALL "ELECTRICAL WORK" WHETHER SPECIFICALLY MENTIONED OR NOT; ALL AS INDICATED, SPECIFIEDHEREIN, AND/OR IMPLIED THEREBY TO CARRY OUT THE APPARENT INTENT THEREOF.5. ALL MATERIALS SHALL BE NEW AND LISTED WITH THE UNDERWRITERS' LABORATORIES, INC., SHALLMEET THEIR REQUIREMENTS AND SHALL BEAR THEIR LABEL WHEREVER STANDARDS HAVE BEENESTABLISHED AND LABEL SERVICE IS REGULARLY FURNISHED BY THAT AGENCY.6. ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH THE SIZE AND LOCATIONSOF EQUIPMENT ARE SHOWN TO SCALE WHEREVER POSSIBLE, CONTRACTOR SHALL MAKE USE OF ALL DATAIN ALL CONTRACT DOCUMENTS AND VERIFY THIS INFORMATION AT THE SITE. CONTRACTOR SHALL BERESPONSIBLE FOR LAYING OUT AND INSTALLING HIS WORK TO AVOID INTERFERENCE WITH OTHER TRADES.7. WORK SHOWN ON THE DRAWINGS TO BE INSTALLED UNDERGROUND SHALL BE INSTALLED AT LEAST 24"BELOW GRADE UNLESS OTHERWISE NOTED. BACKFILL IN 6" THICK, PROPERLY MOISTENED LAYERS,SOLIDLY PACKED AND IRON TAMPED TO A DENSITY NOT LESS THAN THAT OF ADJACENT, UNDISTURBEDEARTH. RESTORE SURFACES, ROADWAYS, WALKS, CURBS, WALLS AND EXISTING UNDERGROUNDINSTALLATIONS TO ORIGINAL CONDITION IN AN ACCEPTABLE MANNER.8. ALL ELECTRICAL EQUIPMENT EXPOSED TO THE WEATHER SHALL BE LISTED FOR EXTERIOR USE.9. ALL U.L. LISTED EQUIPMENT SHALL BE INSTALLED AS PER THEIR LISTING OR LABELING.10. IN LOCATIONS WHERE ELECTRICAL EQUIPMENT WOULD BE EXPOSED TO PHYSICAL DAMAGE,ENCLOSURES OR GUARDS SHALL BE SO ARRANGED AND OF SUCH STRENGTH AS TO PREVENT SUCHDAMAGE.11. CONFLICTS BETWEEN SPECIFICATIONS AND PLANS:a. ANY CONFLICT BETWEEN ELECTRICAL SPECIFICATIONS AND ELECTRICAL PLANS; OR BETWEENELECTRICAL PLANS AND PLANS OF ANOTHER DISCIPLINE SHALL BE BROUGHT TO THE ATTENTION OF THEENGINEER AND A RESOLUTION RECEIVED PRIOR TO PROCUREMENT OR INSTALLATION OF THE ITEM INQUESTION.b. IF THE CONTRACTOR PROCEEDS WITH THE WORK WITHOUT RECEIVING ANY RESOLUTION TO THECONFLICT HE/SHE DOES SO AT HIS/HER OWN RISK AND SHALL RECTIFY THE WORK TO THE SATISFACTIONOF THE ENGINEER AT NO ADDITIONAL COST TO THE OWNER OR ENGINEER.260500.01. HVAC SYSTEMS:1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACTLOCATIONS OF ALL HVAC UNITS, DISCONNECTS AND DEVICES IN FIELD. COORDINATE ROOF PENETRATIONSFOR DISCONNECTS AND WEATHERPROOF OUTLETS WITH ELECTRICAL CONNECTION POINTS ON THE UNITSTO KEEP FLEXIBLE CONDUIT LENGTH TO A MINIMUM (36" MAXIMUM). VERIFY AND CONFIRM THE ACTUALMOUNTING LOCATION ON THE HVAC UNIT FOR THE DISCONNECT. ALL SERVICING OUTLETS ON THE ROOFOR OUTDOORS FOR HVAC UNITS SHALL BE WP/GFI.2. THE RATING OF THE DISCONNECT SHALL BE SUCH AS TO ENABLE THE LARGEST FUSE SIZE ON THEUNIT NAMEPLATE TO BE INSTALLED IN THE DISCONNECT. PROVIDE FUSES OF THIS RATING.3. FURNISH AND INSTALL ALL LINE VOLTAGE CONDUITS AND LINE VOLTAGE WIRING (LOW VOLTAGECONDUITS AND WIRING BY MECHANICAL) TO HVAC EQUIPMENT AND ASSOCIATED CONTROLS AND DEVICESAS SHOWN ON THE ELECTRICAL AND MECHANICAL PLANS, UNLESS OTHERWISE NOTED.4. RUN ALL CONDUITS FOR ROOFTOP EQUIPMENT WITHIN CEILING SPACE BELOW. SURFACE CONDUITRUNS ON THE ROOF ARE NOT PERMITTED ON THIS PROJECT.5. DISCONNECTS SHALL NOT BE USED AS THROUGH RACEWAYS FOR WIRING NOT DIRECTLY SERVINGTHE DISCONNECTS. SERVICING OUTLETS SHALL NOT BE MOUNTED ON DISCONNECTS.260500.02. SUBMITTALS:1. PROVIDE THE FOLLOWING SUBMITTALS FOR REVIEW AND APPROVAL. EACH SHALL BE SUBMITTEDSEPARATELY TO AVOID DELAYS IN THE REVIEW OF ONE SUBMITTAL IN HOLDING UP REVIEW OF THEREMAINDER.e. LIGHTING CONTROLSb. PANEL BOARDSf. BASIC ELECTRICAL MATERIALSc. LIGHT FIXTURES260500.03. WORKING CLEARANCES FOR ELECTRICAL SWITCHGEAR:1. PROVIDE WORKING SPACES FOR ELECTRICAL PANELS AND SWITCHGEAR TO COMPLY WITH CEC110.26.2. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL TRADES INVOLVED TO ENSURE THECLEARANCES REQUIRED BY ITEM 1 ABOVE ARE PROVIDED.260526. GROUNDING:1. GROUND AND BOND ALL EQUIPMENT AS REQUIRED BY GOVERNING CODES AND SPECIFICALLYINCLUDING SWITCHBOARD, PANELBOARDS, MOTOR CASES, METAL PIPING SYSTEMS, STRUCTURAL STEEL,ETC.2. PROVIDE GROUND WIRES IN ALL FEEDERS AND BRANCH CIRCUITS, SIZE PER CEC TABLE 250.1223. ALL GROUND WIRES SHALL BE INSULATED GROUND WIRES.260529. INSTALLATION OF SUPPORT SYSTEMS1. RACEWAYS, CABLE ASSEMBLIES, BOXES, CABINETS, AND FITTINGS SHALL BE SECURELY FASTENEDIN PLACE PER CEC ARTICLE 300.11. SUPPORT WIRES THAT DO NOT PROVIDE SECURE SUPPORT SHALL NOTBE PERMITTED AS THE SOLE SUPPORT. SUPPORT WIRES AND ASSOCIATED FITTINGS THAT PROVIDESECURE SUPPORT AND THAT ARE INSTALLED IN ADDITION TO THE CEILING GRID SUPPORT WIRES SHALL BEPERMITTED AS THE SOLE SUPPORT. WHERE INDEPENDENT SUPPORT WIRE ARE USED, THEY SHALL BESECURED AT BOTH ENDS. CABLES AND RACEWAYS SHALL NOT BE SUPPORTED BY CEILING GRIDS.2. FURNISH ALL NECESSARY FOUNDATIONS, SUPPORTS, BACKING, ETC., FOR ALL ELECTRICALENCLOSURES, CONDUITS AND EQUIPMENT.3. ATTACH ALL BOXES, CABINETS, ETC. TO WOOD WITH WOOD OR LAG SCREWS, TO METAL WITHMACHINE SCREWS OR BOLTS AND TO CONCRETE WITH EXPANSION ANCHORS AND MACHINE SCREWS ORBOLTS.2. RIGID STEEL CONDUIT SHALL BE SUPPORTED AT INTERVALS NOT GREATER THAN 10 FT, ELECTRICALMETALLIC TUBING AT INTERVALS NOT GREATER THAN 5 FT.3. A SUPPORT SHALL BE PROVIDED NOT MORE THAN 3 FT. FROM ANY CHANGE IN DIRECTION.ADDITIONAL SUPPORTS TO THOSE SPECIFIED ABOVE SHALL BE INSTALLED WHERE REQUIRED TO SUIT JOBCONDITIONS AND TO PROVIDE A SECURE INSTALLATION. ALL HANGERS AND SUPPORTS SHALL BE THEPRODUCTS OF ONE MANUFACTURER.260533. PULL OR JUNCTION BOXES:1. INSTALL WHERE INDICATED, OR AS REQUIRED BY CODE, PULL BOXES AND JUNCTION BOXES OFSUFFICIENT SIZE AND CAPACITY TO FACILITATE ALL WIRING. BOXES SHALL BE SIZED TO PROPERLYACCOMMODATE ALL CONDUCTORS ENTERING SAME.2. BOXES SHALL BE OF THE SHAPE AND SIZE BEST SUITED FOR THE PARTICULAR APPLICATION ANDSHALL BE SUPPORTED DIRECTLY TO STRUCTURAL MEMBERS, FRAMING OR BLOCKING BY MEANS OFSCREWS, ANCHORS, BOLTS OR EMBEDDED IN MASONRY.A. SWITCH AND RECEPTACLE BOX SHALL BE ONE PIECE DRAWN OR STAMPED STEEL BOXESMINIMUM SIZE SHALL BE FOUR INCHES (4") SQUARE. BOXES SHALL BE FITTED WITH FLUSH DEVICECOVERS, PLASTER RINGS, OR TILE SWITCH RINGS IN MASONRY IN AREA WHERE EXPOSED WIRING ISPERMISSIBLE, BOXES SHALL BEFITTED WITH SURFACE TYPE COVERS.B. LIGHTING OUTLETS SHALL BE FOUR INCHES (4")OCTAGON, MINIMUM.C. WEATHERPROOF BOXES SHALL BE APPLETON FD SERIES AND FITTED WITH GASKETED CASTCOVERS.D. VOICE/DATA OUTLET BOXES SHALL BE 4_11/16"SQ.x2_1/8" DEEP MINIMUM, FITTED WITH PLASTERRINGS.E. BOXES FOR SPECIAL EQUIPMENT SHALL BE SUITABLE FOR THE PARTICULAR EQUIPMENT.F. BOXES SHALL BE LOCATED AND PLACED ACCORDING TO ARCHITECTURAL AND STRUCTURALREQUIREMENTS.260550. WIRING METHODS: LINE VOLTAGE SYSTEMS (120V AND ABOVE):1. ALL WIRING SHALL BE INSTALLED IN CONDUITS. CONDUITS SHALL BE RUN CONCEALED IN WALLSAND CEILINGS WHERE FEASIBLE. ALL CONDUITS INSTALLED SURFACE ON WALL SHALL BE PAINTED TOMATCH WALL FINISH. MOUNT EXTERIOR CONDUITS ON WALL ON GALVANIZED UNISTRUTS. ALL SURFACECONDUIT INSTALLATION/ RUNS SHALL BE APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION.2. ALL CONDUITS RUN IN DEDICATED ELECTRICAL AND MECHANICAL ROOMS SHALL BE RUNEXPOSED.3. MINIMUM CONDUIT SIZE SHALL BE 1/2" ABOVE GRADE AND 3/4" UNDERGROUND.4. MINIMUM ACCEPTABLE CONDUITS ARE:A. GALVANIZED RIGID STEEL - FOR USE ON:(1) EXTERIOR WALL SURFACES.B. GALVANIZED STEEL EMT FOR USE:(1) CONCEALED IN INDOOR FINISHED SPACES.(2) EXPOSED INSIDE ELECTRICAL & MECHANICAL ROOMS.C. LIQUID TIGHT STEEL FLEX:(1) FOR FINAL CONNECTION TO OUTDOOR EQUIPMENT. LENGTH SHALL NOT EXCEED 36".D. FLEXIBLE STEEL CONDUIT:(1) FOR INDOOR FINAL CONNECTION TO RECESSED LIGHT FIXTURES. LENGTH SHALL NOT EXCEED 72".(2) FOR INDOOR FINAL CONNECTION TO HVAC EQUIPMENT. LENGTH SHALL NOT EXCEED 36".E. "PVC" SCHEDULE 40:(1) FOR CONDUITS RUN UNDERGROUND AND FOR UNDER BUILDING SLAB.(2) CONDUIT STUBUPS THROUGH THE FLOOR OR GRADE SHALL BE IN PVC WRAPPED RIGID STEELCONDUIT. PVC WRAPPING SHALL EXTEND 6" ABOVE FINISHED FLOOR OR GRADE.(3) NOT PERMITTED FOR WIRING ABOVE FINISHED FLOOR INSIDE BUILDINGSF. ALUMINUM CONDUITS, IMC CONDUITS OR ALUMINUM FITTINGS ARE NOT APPROVED FOR USE ONTHIS PROJECT.G. ALL CONDUIT FITTINGS SHALL BE MALLEABLE IRON/STEEL.H. COUPLING:(1) EMT COUPLING - APPLETON TWC-CS SERIES(2) EMT CONNECTOR - APPLETON TW-CSI SERIES(3) FLEX CONDUIT CONNECTOR - T&B "TITE BITE", INSULATED(4) LIQUID TIGHT FLEX CONDUIT CONNECTOR - APPLETON "STB" SERIES UP TO 2", "ST" SERIES OVER 2".I. RIGID STEEL CONDUIT CONNECTED TO BOXES AND CABINETS SHALL BE FITTED WITH TWOLOCKNUTS AND INSULATING BUSHING, OA "A" SERIES. PROVIDE GROUNDING BUSHING OZ "BL" SERIESWHERE LOCKNUTS AND BUSHING IS NOT USED. CONDUITS CONNECTED TO BOXES EXPOSED TOWEATHER/MOISTURE SHALL BE FITTED WITH WATERTIGHT SEALING HUBS OF STEEL OR MALLEABLEIRON WITH SEALING RING AND INSULATED THREAT, T & B 370 SERIES.J. TYPE NM AND NMC CABLES SHALL NOT BE USED ON THIS PROJECT.K. THE PROJECT DRAWINGS ARE LAID OUT USING SOLID CONDUITS AND CABLES PULLED THROUGHSUCH CONDUITS. MC CABLES MAY BE UTILIZED AS DESCRIBED BELOW, WITH RESTRICTIONS NOTED.(1) PRIOR APPROVAL OF OWNER/ARCHITECT OR ENGINEER REQUIRED.(2) MC CABLES SHALL BE AS MANUFACTURED BY SOUTHWIRE TYPE EZ-MC DURACLAD TYPE WITH LIGHTWEIGHT STEEL ARMOR AND INSULATED GREEN GROUNDING CONDUCTORS OR APPROVED EQUAL.(3) SHALL BE USED FOR BRANCH CIRCUITS ONLY AS NOTED BELOW.(a) CANNOT BE USED ANYWHERE EXPOSED.(b) LIGHTING: VERTICAL DROPS IN WALL FOR LIGHT SWITCHES FORM JBOX IN CEILING. HORIZONTALRUNS IN CEILING SHALL BE IN SOLID STEEL CONDUITS.(A) FOR UNDERGROUND HOMERUNS: SOLID CONDUIT VERTICAL RISER IN WALL FROM UNDERGROUNDCONDUIT TO FIRST RECEPTACLE JBOX. THEN HORIZONTAL RUNS WITHIN WALLS TO OTHERRECEPTACLE BOXES IN MC CABLE.(B) FOR OVERHEAD HOMERUNS: VERTICAL DROPS FROM JBOX IN CEILING THEN HORIZONTAL RUNSWITHIN WALLS TO OTHER RECEPTACLES. HORIZONTAL RUNS IN CEILING SHALL BE IN SOLID STEELCONDUITS.(d) NO OTHER USE IS PERMITTED WITHOUT SPECIFIC WRITTEN APPROVAL OF THE ARCHITECT ORENGINEER.(4) ALL FITTINGS AND TERMINATIONS FOR THE MC CABLING SYSTEM SHALL BE METAL AND SUITABLEAND LISTED FOR SUCH USE.(5) ALL SUPPORTS, ATTACHMENTS SPACING SHALL BE PER CEC 330.30.(6) FOR MULTI-WIRE BRANCH CIRCUITS SUCH CABLES SHALL HAVE MULTIPLE NEUTRALS, ONE FOREACH CIRCUIT.6. CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE THHN/THWN UNLESS OTHERWISE NOTEDOR REQUIRED BY CODE.7. ALL DEVICES, CONDUITS, RACEWAYS AND CABLES SHOWN ARE NEW TO BE PROVIDED UNLESSOTHERWISE NOTED.8. FLASH AND COUNTERFLASH ALL ITEMS PASSING THROUGH THE ROOF.9. THE OWNER RESERVES THE RIGHT TO RELOCATE ALL LIGHTING, OUTLETS AND SWITCHES BEFORETHEY ARE ROUGHED IN AT NO EXTRA COST.10. SEPARATION OF WIRING OF DIFFERENT VOLTAGE CLASSIFICATIONS:260551. INSTALLATION OF RACEWAYS AND FITTINGS1. CONCEAL RACEWAYS WITHIN CEILINGS, WALLS, AND FLOORS EXCEPT WHERE EXPOSEDRACEWAYS ARE SPECIFICALLY PERMITTED.2. WHERE CONDUIT IS ALLOWED TO BE EXPOSED, INSTALL THE CONDUIT PARALLEL WITH OR ATRIGHT ANGLES TO STRUCTURAL MEMBERS, WALLS, AND LINES OF THE BUILDING.3. INSTALL WHERE INDICATED, OR AS REQUIRED BY CODE, PULLBOXES AND JUNCTION BOXES OFSUFFICIENT SIZE TO FACILITATE WIRING. BOXES SHALL BE SIZED TO PROPERLY ACCOMMODATE ALLCONDUCTORS ENTERING SAME.4. DO NOT INSTALL CONDUIT OR TUBING WHICH HAS BEEN CRUSHED OR DEFORMED.5. RUN CONDUCTORS OF SAME CIRCUIT IN SAME CONDUIT. RUN CONDUCTORS OF DIFFERENTVOLTAGE SYSTEMS IN SEPARATE CONDUITS.6. INSTALL NO CONDUCTORS UNTIL WORK WHICH MIGHT CAUSE DAMAGE TO SUCH CONDUCTORSOR THE CONDUIT HAS BEEN COMPLETED.7. KEEP ALL CONDUITS AT LEAST SIX INCHES AWAY FROM THE COVERING ON HOT WATER OR STEAMPIPES.8. CAP RACEWAY ENDS DURING CONSTRUCTION. CLEAN OR REPLACE CONDUITS IN WHICH WATEROR FOREIGN MATTER HAVE ACCUMULATED, TO THE SATISFACTION OF THE ARCHITECT.9. CONDUITS SHALL BE SUPPORTED WITH STRAPS, WITH GALVANIZED MALLEABLE SPLIT RING ANDROD FOR INDIVIDUAL RUNS OR WITH KINDORF OR UNISTRUT CHANNEL SUPPORTS FOR MULTIPLE RUNS.DISTANCE BETWEEN SUPPORTS SHALL NOT EXCEED 10 FEET. CONDUITS SHALL BE SUPPORTEDINDEPENDENTLY OF ONE ANOTHER.10. CONDUITS CONNECTED TO BOXES AND CABINETS SHALL BE FITTED WITH TWO LOCKNUTS ANDINSULATED BUSHING, OA "A" SERIES.11. CONDUITS NOT CONNECTED WITH LOCKNUTS AND BUSHINGS SHALL BE FITTED WITH GROUNDINGBUSHING, OZ "BL" SERIES, U. L. APPROVED AND BONDED.12. CONDUIT STRAPS FOR INDIVIDUAL RUNS SHALL BE SECURED BY TOGGLE BOLTS ON HOLLOWMASONRY, EXPANSION ANCHORS ON SOLID CONCRETE OR MASONRY, MACHINE SCREWS OR BOLTS ONMETAL SURFACES AND WOOD SCREWS ON WOOD CONSTRUCTION. THE USE OF NAILS TO ANCHORSTRAPS ON WOOD CONSTRUCTION IS PROHIBITED. STRAPS SHALL BE TWO HOLE MALLEABLE IRON ORSNAP-TYPE STEEL WITH RIBBED BACK, GALVANIZED OR CADMIUM PLATED. THE USE13. PLACEMENT OF ALL BOXES SHALL BE GOVERNED BY APPLICABLE ARCHITECTURAL ANDSTRUCTURAL REQUIREMENTS.14. CONDUIT FITTINGS: EXCEPT WHERE OTHERWISE NOTED, CONDUIT FITTINGS SHALL BE APPLETONOR APPROVED EQUAL. UNILETS SHALL BE MALLEABLE IRON AND FITTED WITH COVERS AND GASKETS.15. TELEPHONE AND SIGNAL CONDUIT BENDS WHERE REQUIRED SHALL HAVE A RADIUS OF TEN TIMESTHE CONDUIT TRADE SIZE.16. PROVIDE PULL TAPE IN ALL EMPTY CONDUITS.260553. NAMEPLATES & IDENTIFICATION:1. INSTALL ENGRAVED NAMEPLATES FOR EACH PANELBOARD, CABINET, DISCONNECT, ETC.NAMEPLATES SHALL BE SECURELY FASTENED TO THE EQUIPMENT WITH #4 PHILLIPS ROUND HEADCADMIUM PLATED SELF-TAPPING SCREWS, BRASS BOLT.2. PROVIDE CIRCUIT LABEL INDICATING PANEL AND CIRCUIT NUMBER ON EACH COVERPLATE FOREACH RECEPTACLE AND LIGHT SWITCH, MOTION SENSOR SWITCH. SUCH LABEL SHALL BE SELF ADHESIVEWHITE TAPE WITH BLACK LETTERS MADE ON A LABEL MAKER.3. ALL CONTROLLED RECEPTACLES SHALL BE PERMANENTLY MARKED TO DIFFERENTIATE THEMFROM UNCONTROLLED RECEPTACLES PER CALIFORNIA ENERGY CODE SECTION 130.5(d)(3).260573. ARC FLASH HAZARDS:1. PROVIDE WARNING LABEL ON ELECTRICAL EQUIPMENT OF POSSIBLE ARC FLASH HAZARDS PERC.E.C. 110.16.260800. TESTING:1. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE FREE FROM SHORT CIRCUITS AND IMPROPERGROUNDS. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND GROUNDS BEFORE ANY FIXTURESOR EQUIPMENT ARE CONNECTED AND WHERE SUCH TESTS INDICATE FAULTY INSULATION OR OTHERDEFECTS, THEY SHALL BE LOCATED, REPAIRED AND RETESTED AT THE CONTRACTOR'S EXPENSE.PROVIDE ALL INSTRUMENTS TO MAKE SUCH TESTS.2. DEMONSTRATE TO THE OWNER AND THE ARCHITECT, THAT THE ENTIRE INSTALLATION ISCOMPLETE, IN PROPER OPERATING CONDITION AND THAT THE CONTRACT HAS BEEN PROPERLY ANDFULLY EXECUTED.260800.01. CERTIFICATE OF COMPLETION:1. ACCEPTANCE OF THE CONTRACT FOR THIS WORK INCLUDES THIS GUARANTEE: THE CONTRACTORGUARANTEES THAT HE HAS PERFORMED THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.CONTRACTOR AGREES TO REPLACE OR REPAIR, AS NEW ANY DEFECTIVE WORK, MATERIALS, OR PARTWHICH MAY APPEAR WITHIN ONE YEARS (1) OF FINAL ACCEPTANCE, IF, IN THE OPINION OF THEARCHITECT OR THE OWNER, THE DEFECT IS DUE TO WORKMANSHIP OR MATERIAL.260800.02. WARRANTIES, GUARANTEES, CERTIFICATES, ETC.:1. WARRANTIES, GUARANTEES, CERTIFICATES, ETC. THAT ARE FURNISHED AND AVAILABLE FOREQUIPMENT AND MATERIALS FURNISHED AND INSTALLED UNDER THIS SECTION SHALL BE PROPERLYFILLED OUT AS OF DATE OF ACCEPTANCE OF THE WORK BY THE OWNER AND SHALL BE DELIVERED TOTHE ARCHTITECT.260811. OPERATIONS AND MAINTENANCE (O&M) MANUALS:1. PROVIDE AS-BUILT DRAWINGS.A. UPON COMPLETION OF WORK COVERED BY THIS CONTRACT, PROVIDE AS-BUILT PLANS UPONWHICH SHALL BE SHOWN ALL CHANGES OF FEEDERS, PANELS, CIRCUITS, LIGHT FIXTURES, ETC., FOR THISPROJECT AND INSTALLED UNDER THIS CONTRACT, WHICH ARE NOT IN ACCORD WITH THESE DRAWINGSFOR THE WORK.B. ALL SYMBOLS AND DESIGNATIONS USED IN PREPARING "AS-BUILT" DRAWINGS SHALL MATCHTHOSE USED IN CONTRACT DRAWINGS.2. PROVIDE OF OPERATION AND MAINTENANCE MANUAL FOR POWER, AND LIGHTING SYSTEMS.3. SCAN BOTH "AS-BUILT" PLANS AND O&M MANUAL ON TO A CD AND PROVIDE (3) COPIES OF THE CDTO OWNER PRIOR TO RELEASE OF FINAL PAYMENT.260943. INTERIOR LIGHTING CONTROL SYSTEM:1. PROVIDE A COMPLETE AND FULLY OPERATIONAL INTERIOR LIGHTING CONTROL SYSTEM FORINTERIOR LIGHTING AS SPECIFIED HEREIN AND SHOWN ON THE DRAWINGS.2. THE COMPLETE SYSTEM, INCLUDING ALL DEVICES SHALL BE IN COMPLIANCE WITH THE 2019CALIFORNIA ENERGY CODE.3. THE COMPLETE SYSTEM SHALL BE AS MANUFACTURED BY NLIGHT, WATTSTOPPER, ORGREENGATE CONSISTING OF:A. LUMINARIES WITH 0-10V DIMMING LED DRIVERS.B. WALL DIMMER SWITCHES THAT COMMUNICATE THROUGH ROOM CONTROLLERS.C OCCUPANCY SENSORS THAT COMMUNICATE THROUGH ROOM CONTROLLERS.D WHERE LIGHT FIXTURES FALL UNDER THE PRIMARY AND SECONDARY DAYLIT ZONES AS DEFINEDBY SECTION 130.1(d)AND THE TOTAL INSTALLED GENERAL LIGHTING POWER IN THE PRIMARY DAYLIT ZONEISNOT LESS THAN 120W (EXCEPTION #1 TO SECTION 130.1(d)2) SUCH LIGHT FIXTURES SHALL BE PROVIDEDWITH AUTOMATIC DAYLIGHITNG CONTROLS IN ACCORDANCE WITH SECTION 130.1(d)(2)(D).E. PROVIDE A DEMAND RESPONSIVE CONTROLS FOR THE INTERIOR LIGHTING SYSTEM PER CECSECTION 130.5(e). PROVIDE A GATEWAY DEVICE TO ACHIEVE THIS. SET UP DEVICE SUCH THAT WHEN ITRECEIVES AN OPEN AUTOMATIC DEMAND RESPONSE (ADR) 2.0 SIGNAL IT TRANSMITS THE ADR SIGNAL TOEACH OTHER AND TO THE ROOM LIGHTING CONTROLLERS. THE ROOM CONTROLLERS SHALL DIM THELIGHT FIXTURES TO REDUCE ENERGY CONSUMPTION BY AT LEAST 15%, BUT NOT MORE THAN 50% WHENTHE SIGNAL IS RECEIVED.F. TIME BASED GATEWAY DEVICE THAT PROVIDES TIME-BASED SIGNAL TO ROOM CONTROLLERS FORALL SPACES THAT CONTROLLED BY MOTION SENSORS TO AUTOMATICALLY SHUT-OFF LIGHTS AT THE ENDOF DAY4. ALL SYSTEM COMPONENTS SHALL BE UL LISTED. ALL SYSTEM CONTROL COMPONENTS SHALL BEAPPROVED BY THE CALIFORNIA ENERGY COMMISSION.5. ALL EQUIPMENT AND ITEMS OF CONTROL SHALL BE INSTALLED AND WIRED IN ACCORDANCE WITHMANUFACTURER'S REQUIREMENTS.6. PROVIDE WALL OCCUPANCY SENSOR LIGHT SWITCHES WHERE SO SHOWN ON PLANS. SUCHOCCUPANCY SENSOR SWITCHES SHALL BE SINGLE LEVEL AUTOMATIC "ON"/AUTOMATIC "OFF" AS SHOWNON PLANS. SENSORS SHALL COMPLY WITH SECTION 110.9 OF THE ENERGY CODE.7. THE SYSTEM SHALL AUTOMATICALLY SWITCH OFF ALL LIGHTS WHEN CONTROLLED SPACEBECOMES UNOCCUPIED AND SWITCH ON LIGHTS WHEN THE SPACE IS RE-OCCUPIED. ALL SENSORS SHALLBE PROVIDED WITH USER ADJUSTABLE TIME DELAY (15 SEC. TO 20 MINUTES) FOR "SWITCH-OFF" FUNCTIONAND ADJUSTABLE SENSITIVITY.262417. PANELBOARDS:1. UNITS SHALL BE FLUSH OR SURFACE MOUNTED AS INDICATED ON THE PANEL SCHEDULE, WITH THENUMBER AND SIZE OF BREAKERS AS INDICATED ON THE PANEL SCHEDULE. SINGLE POLE, TWO POLE, ANDTHREE POLE BREAKERS SHALL BE BOLT-ON TYPE. MULTIPLE POLE BREAKERS SHALL HAVE COMMONINTERNAL TRIP CONNECTION. SINGLE POLE BREAKERS SHALL NOT BE TIED AT HANDLES TO FORMMULTIPLE POLE BREAKERS. THE PANEL DOORS SHALL BE DOOR-IN-DOOR CONSTRUCTION AND SHALLHAVE FLUSH TYPE LOCKS, ALL LOCKS SHALL BE KEYED ALIKE AND HAVE TYPEWRITTEN DIRECTORIESINDICATING FIXTURES, EQUIPMENT, OR OUTLETS SERVICE BY EACH BREAKER. PANELS SHALL HAVECOPPER BUSSING.262726. WIRING DEVICES:1. UNITS SHALL BE EQUAL TO THE DEVICES SET FORTH HEREIN, IN STANDARD COLORS (BROWN,WHITE, GREY, BEIGE OR IVORY) AS SELECTED BY THE ARCHITECT:A. WIRING DEVICES LEVITON # HUBBELL # P & S #SINGLE POLE SWITCH, 15A 1201-2 HBL1201 PS15AC1DOUBLE POLE SWITCH, 15A 1202-2 HBL1202 PS15AC2THREE WAY SWITCH, 15A 1203-2 HBL1203 PS15AC3DUPLEX CONV. OUTLET, 15A 5262 HBL5262 5262DUPLEX CONV. OUTLET, 20A 5362 HBL5362 5362DUPLEX CONV. GFI OUTLET, 15A 6599 GF15 1595LDUPLEX CONV. GFI OUTLET, 20A 6899 GF15 2095L2. THE MOUNTING HEIGHTS OF LIGHT SWITCHES, RECEPTACLES AND CONTROLS SHALL BE MAXIMUM48" MEASURED TO THE TOP OF BOXES OR MINIMUM 16" TO THE BOTTOM OF BOXES. SEE "LEGEND" FORACTUAL MOUNTING HEIGHTS OF DEVICES. VERIFY HEIGHT WITH ARCHITECT WHERE AN ACTUAL MOUNTINGHEIGHT IS NOT CALLED OUT ON PLANS.3. SINGLE RECEPTACLE SERVED BY INDIVIDUAL 20A BRANCH CIRCUIT DEDICATED TO THE OUTLETSHALL BE 20A RATED PER CEC 210.21(B)(1). ALL OTHERS SHALL BE 15A RATED.4. ALL RECEPTACLES INSTALLED OUTDOORS SHALL BE WEATHERPROOF AND HAVE GROUND FAULTCIRCUIT INTERRUPTER PROTECTION.5. 120V, 15A AND 20A RECEPTACLES ARE NOW SUBJECT TO CALIFORNIA ENERGY CODE, SECTION130.5(d). ALL SUCH OUTLETS SHALL BE CONSIDERED AS UNCONTROLLED EXCEPT THOSE WHICH ARESPECIFICALLY CALLED OUT ON THE PLANS AS CONTROLLED. SEE "CONTROLLED 120V RECEPTACLES"PARAGRAPH BELOW.262726.02. DEVICE PLATES:1. ALL DEVICE PLATES FOR INDOOR USE SHALL BE NYLON.2. ALL DEVICE BOXES WHICH ARE INSTALLED IN FIRE RATED WALL ASSEMBLY AND IS PROVIDED WITHA FIRE-STOPPING PUTTY PAD SHALL HAVE A BRUSHED STAINLESS STEEL COVERPLATE IN ACCORDANCEWITH THE REQUIREMENTS OF THE PUTTY PAD.3. DEVICE COVERS FOR SURFACE MOUNTED BOXES SHALL BE 1/2" RAISED STEEL PLATES.4. DEVICE COVERS FOR DEVICES LOCATED IN DAMP LOCATIONS SHALL COMPLY WITH CEC 406.9(A).5. DEVICE COVERS FOR DEVICES LOCATED IN WET LOCATIONS SHALL COMPLY WITH CEC 406.9(B).262729. DISCONNECT SWITCHES:1. UNITS SHALL BE HEAVY DUTY FUSED DISCONNECT SWITCHES, TWO OR THREE POLE TYPE, WHEREINDICATED ON THE DRAWINGS, OR AS REQUIRED BY CODE. SWITCHES AND FUSES SHALL BE AS REQUIREDBY THE LOADS SERVING.2. DISCONNECTS FOR FRACTIONAL HORSE POWER MOTORS SHALL BE MOTOR-RATED TOGGLE TYPEDISCONNECTS.3. DISCONNECTS FOR SINGLE PHASE MOTORS SHALL BE SINGLE PHASE AND NOT THREE PHASE.4. LOCATE DISCONNECTS IN ACCORDANCE WITH CEC 430.102. ENSURE ALL CODE-REQUIREDCLEARANCES.