Laserfiche WebLink
Secondary • <br /> Vacuum Sensing System <br /> Maximize protection with a vacuum <br /> h �F <br /> monitored secondary containment ? <br /> system . <br /> A Secondary Containment Vacuum Features and Benefits • Facilitates periodic operability testing <br /> Sensing System for use with Veeder- Satisfy Requirements Leverage Existing Veeder>Root Systems <br /> Root's ATG Systems. The Secondary Certified to meet Califomia's requirement for • Uses STP as the vacuum source and works with <br /> Containment Vacuum Sensing (SCVS) secondary space monitoring for tanks and lines Red Jacket and FE SM <br /> as required by AB 2481 . Installs in the STP sump and connects to the <br /> System is designed to detect leaks in double- Satisfies the requirements for Class I Leak console via intrinsically safe wiring <br /> walled tanks and piping systems while Detection as defined by the European . Able to share wiring conduit with other <br /> helping to contain a release of product while Standard EN 13160-2 Veeder Root intrinsically safe (IS) probes and <br /> under vacuum. The system consists of: 3rdlisted National Work Group and LG113 sensors including sump or line leak sensors <br /> • Interfaces to the Smart Sensor Interface with <br /> • <br /> Embedded Pressure Module <br /> Vacuum Sensors, connected to tank, Reduce Exposure to Risk <br /> Alarms when vacuum cannot be maintained Provides for positive shut down of pressurized <br /> sump or piping interstices lines when required <br /> • A Submersible Turbine Pump (STP) , or when replenish rate exceeds is liters per hour Simple installation, no need to mess with brine <br /> • The system alarms when liquid is detected in <br /> to provide a source of vacuum the secondary space <br /> • A Smart Sensor Interface with Embedded <br /> Pressure Module in a TLS-350 Operating Temperature Rating: Console Capability <br /> MonitoringSystem -25 degrees C to +70 degrees C The Vacuum Sensor Is compatible with <br /> y the following consoles: <br /> The Vacuum Sensor is interfaced to Veeder Cable Length: Console8 feet TLS-350R/EMC WOW <br /> Root's TLS-350 Monitoring System via TLS-350 Plus/EMC Enhanced* <br /> intrinsically safe wiring to provide system Sensor Dimensions• TLS-350/EMC* <br /> status, replenish rate, alarm, and diagnostic 5' high x 5" wide 2" dee *Upgrade Note: The Vacuum Sensor System requires <br /> 9 p the console to have version 24C software (or greater) <br /> information. along with an ECPU2 or ECPU w/ NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a variety Veeder-Hoot P/N Description <br /> 330020-467 4 Vacuum Sensor Kit* for steel tank <br /> of models: 330020-468j-46%-470,471 4 Vacuum Sensor Kit* for fiberglass tanks (4',6',8' ,10') <br /> 330020-486 4 Vacuum Sensor Kit* for no tank <br /> • For monitoring double-walled piping 330020-472 3 Vacuum Sensor Kit* for steel tank <br /> 330020-4739-4741-4759-476 3 Vacuum Sensor Kit* for fiberglass tanks W ,6' ,8%10') <br /> and sump interstices 330020-485 3 Vacuum Sensor KIV for no tank <br /> • For monitoring double-walled steel tank 330020-479 2 Vacuum Sensor Kit' for steel tank <br /> 330020-481 ,-4829-483,-484 2 Vacuum Sensor Kit* for fiberglass tanks (4',6%8%106) <br /> interstices (see back page) <br /> 330020-480 2 Vacuum Sensor Kit* for no tank <br /> • For double-walled fiberglass tanks 330020-495 1 Vacuum Sensor Kit' for no tank <br /> 857280-100 Vacuum Sensor for piping & sumps <br /> 857260-200 Vacuum Sensor for steel tanks <br /> These kits differ in the number of vacuum <br /> 857280-301 - 3029-303p-304 Vacuum Sensor for fiberglass tanks (4',6',8',10') <br /> sensors and the configuration of associated 330020-448 Mounting Kit <br /> liquid sensors. An inline kit mounted liquid 332217-001 Relief Valve Assembly <br /> 332250-001 Smart Sensor w/Embedded Pressure Sensor Module (7 Channeq** <br /> sensor is used for Vacuum Sensors <br /> monitoring piping and sumps. An external Accessories Part Description Quantity/Length Part Number <br /> 1/4" NPT Barbed Fittings 3 330020-487 <br /> liquid sensor (to be installed in the secondary 1 /4" NPT Barbed Fittings 15 330020-468 <br /> space at the bottom of the tank) is provided 1 /4" NPT Barbed Fittings 25 330020-489 <br /> with one of the Vacuum Sensors in the steel Barbed Tee 1 576008-657 <br /> Vacuum Hose 25' 25' 332310-001 <br /> and fiberglass tank kits to monitor the tank. Vacuum Hose 50' 50' 332310-002 <br /> Vacuum Hose 100' 100' 332310-003 <br /> 3-Way Ball Valve 1 576008-649 <br /> Schrader Valve Barbed Fitting 3 330020-496 <br /> Schrader Valve Barbed Fitting 15 330020-497 <br /> Kts include mounting bracket, Vol vacuum hose, relief valve assembly V required) and the appropriate number of liquid sensors, <br /> 3-way ball valves, barbed fringe and hose clamps so that each vacuum sensor can monitor a single tank, sump or piping interstices. <br /> *' The Vacuum Sensing System requires one 7 channel Smart Sensor Interface with Embedded Pressure Module, 8 charnel Smart <br /> Sensor Modules ip/n 329356-004) can be used for Vacuum Sensors e;ght and above. <br /> For more information call : 1 -88x-561 -7942 <br /> �� VEEDER- ROOT <br />